149 related articles for article (PubMed ID: 7869724)
1. Transition to turbulence in pulsatile flow through heart valves--a modified stability approach. Bluestein D; Einav S J Biomech Eng; 1994 Nov; 116(4):477-87. PubMed ID: 7869724 [TBL] [Abstract][Full Text] [Related]
2. The effect of varying degrees of stenosis on the characteristics of turbulent pulsatile flow through heart valves. Bluestein D; Einav S J Biomech; 1995 Aug; 28(8):915-24. PubMed ID: 7673259 [TBL] [Abstract][Full Text] [Related]
3. Time-resolved particle image velocimetry and laser doppler anemometry study of the turbulent flow field of bileaflet mechanical mitral prostheses. Akutsu T; Fukuda T J Artif Organs; 2005; 8(3):171-83. PubMed ID: 16235034 [TBL] [Abstract][Full Text] [Related]
4. Turbulence characteristics downstream of bileaflet aortic valve prostheses. Liu JS; Lu PC; Chu SH J Biomech Eng; 2000 Apr; 122(2):118-24. PubMed ID: 10834151 [TBL] [Abstract][Full Text] [Related]
5. Principal stress analysis in LDA measurement of the flow field downstream of 19-mm Sorin Bicarbon heart valve. Barbaro V; Grigioni M; Daniele C; D'Avenio G Technol Health Care; 1998 Nov; 6(4):259-70. PubMed ID: 9924953 [TBL] [Abstract][Full Text] [Related]
6. Turbulence detection in a stenosed artery bifurcation by numerical simulation of pulsatile blood flow using the low-Reynolds number turbulence model. Ghalichi F; Deng X Biorheology; 2003; 40(6):637-54. PubMed ID: 14610313 [TBL] [Abstract][Full Text] [Related]
7. Flow characteristics past jellyfish and St. Vincent valves in the aortic position under physiological pulsatile flow conditions. Morsi YS; Sakhaeimanesh AA Artif Organs; 2000 Jul; 24(7):564-74. PubMed ID: 10916068 [TBL] [Abstract][Full Text] [Related]
8. 19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (part II: maximum turbulent shear stresses). Barbaro V; Grigioni M; Daniele C; D'Avenio G; Boccanera G Int J Artif Organs; 1997 Nov; 20(11):629-36. PubMed ID: 9464873 [TBL] [Abstract][Full Text] [Related]
9. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves. Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437 [TBL] [Abstract][Full Text] [Related]
10. Comparison of magnetic resonance imaging and Laser Doppler Anemometry velocity measurements downstream of replacement heart valves: implications for in vivo assessment of prosthetic valve function. Fontaine AA; Heinrich RS; Walker PG; Pedersen EM; Scheidegger MB; Boesiger P; Walton SP; Yoganathan AP J Heart Valve Dis; 1996 Jan; 5(1):66-73. PubMed ID: 8834728 [TBL] [Abstract][Full Text] [Related]
11. Analysis of the flow in stenosed carotid artery bifurcation models--hydrogen-bubble visualisation. Palmen DE; van de Vosse FN; Janssen JD; van Dongen ME J Biomech; 1994 May; 27(5):581-90. PubMed ID: 8027092 [TBL] [Abstract][Full Text] [Related]
12. On the monodimensional approach to the estimation of the highest reynolds shear stress in a turbulent flow. Grigioni M; Daniele C; D'Avenio G; Barbaro V J Biomech; 2000 Jun; 33(6):701-8. PubMed ID: 10807991 [TBL] [Abstract][Full Text] [Related]
13. Scale-Resolving Simulations of Steady and Pulsatile Flow Through Healthy and Stenotic Heart Valves. Hoeijmakers MJMM; Morgenthaler V; Rutten MCM; van de Vosse FN J Biomech Eng; 2022 Mar; 144(3):. PubMed ID: 34529056 [TBL] [Abstract][Full Text] [Related]
14. Estimation of turbulent shear stresses in pulsatile flow immediately downstream of two artificial aortic valves in vitro. Nygaard H; Giersiepen M; Hasenkam JM; Westphal D; Paulsen PK; Reul H J Biomech; 1990; 23(12):1231-8. PubMed ID: 2292602 [TBL] [Abstract][Full Text] [Related]
15. Fluid-structure interaction of a pulsatile flow with an aortic valve model: A combined experimental and numerical study. Sigüenza J; Pott D; Mendez S; Sonntag SJ; Kaufmann TAS; Steinseifer U; Nicoud F Int J Numer Method Biomed Eng; 2018 Apr; 34(4):e2945. PubMed ID: 29181891 [TBL] [Abstract][Full Text] [Related]
16. Mean velocity and Reynolds stress measurements in the regurgitant jets of tilting disk heart valves in an artificial heart environment. Maymir JC; Deutsch S; Meyer RS; Geselowitz DB; Tarbell JM Ann Biomed Eng; 1998; 26(1):146-56. PubMed ID: 10355559 [TBL] [Abstract][Full Text] [Related]
17. Laser anemometry measurements of pulsatile flow past aortic valve prostheses. Chandran KB; Cabell GN; Khalighi B; Chen CJ J Biomech; 1983; 16(10):865-73. PubMed ID: 6643525 [TBL] [Abstract][Full Text] [Related]
18. Velocity measurements and flow patterns within the hinge region of a Medtronic Parallel bileaflet mechanical valve with clear housing. Ellis JT; Healy TM; Fontaine AA; Saxena R; Yoganathan AP J Heart Valve Dis; 1996 Nov; 5(6):591-9. PubMed ID: 8953436 [TBL] [Abstract][Full Text] [Related]
19. In vitro fluid dynamic evaluation of the Carbomedics bileaflet heart valve prosthesis in the aortic and mitral positions. Sung HW; Cape EG; Yoganathan AP J Heart Valve Dis; 1994 Nov; 3(6):673-83. PubMed ID: 8000612 [TBL] [Abstract][Full Text] [Related]
20. Experimental investigation of the steady flow downstream of the St. Jude bileaflet heart valve: a comparison between laser Doppler velocimetry and particle image velocimetry techniques. Browne P; Ramuzat A; Saxena R; Yoganathan AP Ann Biomed Eng; 2000 Jan; 28(1):39-47. PubMed ID: 10645786 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]