These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 7869992)

  • 1. Dosimetry for asymmetric x-ray fields.
    Kwa W; Kornelsen RO; Harrison RW; el-Khatib E
    Med Phys; 1994 Oct; 21(10):1599-604. PubMed ID: 7869992
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dose calculation for asymmetric photon fields with independent jaws and multileaf collimators.
    Araki F; Ikeda R; Moribe N; Shirakawa Y; Hatemura M; Shimonobou T; Hirata Y; Takada T; Takahashi M; Matoba M
    Med Phys; 2000 Feb; 27(2):340-5. PubMed ID: 10718137
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dose calculations for asymmetric fields defined by independent collimators using symmetric field data.
    Tsalafoutas IA; Xenofos S; Papalexopoulos A; Nikoletopoulos S
    Br J Radiol; 2000 Apr; 73(868):403-9. PubMed ID: 10844866
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of backscattered radiation from secondary collimator jaws into the beam monitor chamber from a dual energy linear accelerator.
    Ravikumar M; Ravichandran R
    Strahlenther Onkol; 2001 Dec; 177(12):670-5. PubMed ID: 11789406
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Final Aperture Superposition Technique applied to fast calculation of electron output factors and depth dose curves.
    Faddegon BA; Villarreal-Barajas JE
    Med Phys; 2005 Nov; 32(11):3286-94. PubMed ID: 16370417
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalism.
    Yu MK; Murray B; Sloboda R
    Med Phys; 1995 Aug; 22(8):1329-32. PubMed ID: 7476720
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Independent collimator dosimetry for a dual photon energy linear accelerator.
    Slessinger ED; Gerber RL; Harms WB; Klein EE; Purdy JA
    Int J Radiat Oncol Biol Phys; 1993 Oct; 27(3):681-7. PubMed ID: 8226165
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An analytical method to calculate equivalent fields to irregular symmetric and asymmetric photon fields.
    Tahmasebi Birgani MJ; Chegeni N; Zabihzadeh M; Hamzian N
    Med Dosim; 2014; 39(1):54-9. PubMed ID: 24485053
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Verification of a simple point dose calculation method for a dual energy linear accelerator with asymmetric jaws.
    Lee PC
    Med Dosim; 1996; 21(4):227-33. PubMed ID: 8985928
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Extrafocal radiation: a unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams.
    Sharpe MB; Jaffray DA; Battista JJ; Munro P
    Med Phys; 1995 Dec; 22(12):2065-74. PubMed ID: 8746712
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A general method to perform dose calculations along the axis of symmetrical and asymmetrical photon beams.
    Marinello G; Dutreix A
    Med Phys; 1992; 19(2):275-81. PubMed ID: 1584118
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analytical representation of head scatter factors for shaped photon beams using a two-component x-ray source model.
    Yu MK; Sloboda R
    Med Phys; 1996 Jun; 23(6):973-84. PubMed ID: 8798168
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Head scatter off-axis for megavoltage x rays.
    Zhu TC; Bjärngard BE
    Med Phys; 2003 Apr; 30(4):533-43. PubMed ID: 12722805
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Equivalent square as a predictor of depth of dose maximum for megavoltage therapy beams.
    Gosselin M; Evans MD; MacDonald B; Olivares-Pla M; Podgorsak EB
    Med Dosim; 1996; 21(3):145-8. PubMed ID: 8899678
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A dosimetric investigation of scatter conditions for dual asymmetric collimators in open fields.
    Cadman P
    Med Phys; 1995 Apr; 22(4):457-63. PubMed ID: 7609728
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dose computations for asymmetric fields defined by independent jaws.
    Chui CS; Mohan R; Fontenla D
    Med Phys; 1988; 15(1):92-5. PubMed ID: 3127669
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The penumbra of a 6-MV x-ray beam as measured by thermoluminescent dosimetry and evaluated using an inverse square root function.
    Kron T; Elliott A; Metcalfe P
    Med Phys; 1993; 20(5):1429-38. PubMed ID: 8289725
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dosimetric assessment of the field abutment region in head and neck treatments using a multileaf collimator.
    Abdel-Hakim K; Nishimura T; Takaih M; Suzuki S; Sakahara H
    Strahlenther Onkol; 2003 May; 179(5):312-9. PubMed ID: 12740658
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of measured and calculated dose for asymmetric x-ray beams defined by independently movable collimators.
    Prasad SC; Krol A; Bassano DA
    Med Dosim; 1996; 21(2):105-7. PubMed ID: 8807611
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analytical representation of head scatter factors for shaped photon beams using a two-component x-ray source model.
    Yu MK; Sloboda R
    Med Phys; 1995 Dec; 22(12):2045-55. PubMed ID: 8746710
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.