These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Percutaneous placement of a low-profile stent-graft device for aortic dissections. Quinn SF; Duke DJ; Baldwin SS; Bascom TH; Ruff SJ; Swangard RJ; DeHaas DR; Padgett RC; Bergin PJ; Lau S J Vasc Interv Radiol; 2002 Aug; 13(8):791-8. PubMed ID: 12171982 [TBL] [Abstract][Full Text] [Related]
5. Intravascular stenting of acute experimental type B dissections. Moon MR; Dake MD; Pelc LR; Liddell R; Castro LJ; Mitchell RS; Miller DC J Surg Res; 1993 Apr; 54(4):381-8. PubMed ID: 8331933 [TBL] [Abstract][Full Text] [Related]
6. Transcatheter Inoue endovascular graft for treatment of canine aortic dissection. Htay T; Fujiwara H; Sato M; Tanaka M; Sasayama S; Inoue K Heart Vessels; 1996; 11(2):80-5. PubMed ID: 8836755 [TBL] [Abstract][Full Text] [Related]
7. Hemodynamic Effects of Multiple Overlapping Uncovered Stents on Aortic Dissection: Surgical Strategies and Implications for False Lumen Thrombosis. Dai Y; Luo G; Dai X; Liu H Cardiovasc Eng Technol; 2020 Feb; 11(1):24-35. PubMed ID: 31820352 [TBL] [Abstract][Full Text] [Related]
8. Early and medium-term results of stent-graft treatment of DeBakey type III aortic dissection. Kiyotaka I; Shinichi S; Keiji U J Cardiovasc Surg (Torino); 2006 Dec; 47(6):651-7. PubMed ID: 17043611 [TBL] [Abstract][Full Text] [Related]
9. Does prosthetic covering of nitinol stents alter healing characteristics or hemodynamics? Avino A; Johnson B; Bandyk D; Back M; Roth S; Kudryk B; Cantor A J Endovasc Ther; 2000 Dec; 7(6):469-78. PubMed ID: 11194818 [TBL] [Abstract][Full Text] [Related]
10. Experimental assessment of newly devised transcatheter stent-graft for aortic dissection. Kato M; Matsuda T; Kaneko M; Ueda T; Kuratani T; Yoshioka Y; Ohnishi K Ann Thorac Surg; 1995 Apr; 59(4):908-14; discussion 914-5. PubMed ID: 7695417 [TBL] [Abstract][Full Text] [Related]
11. How to guide stent-graft implantation in type B aortic dissection? Comparison of angiography, transesophageal echocardiography, and intravascular ultrasound. Koschyk DH; Nienaber CA; Knap M; Hofmann T; Kodolitsch YV; Skriabina V; Ismail M; Franzen O; Rehders TC; Dieckmann C; Lund G; Reichenspurner H; Meinertz T Circulation; 2005 Aug; 112(9 Suppl):I260-4. PubMed ID: 16159828 [TBL] [Abstract][Full Text] [Related]
12. Extensive iatrogenic aortic dissection during renal angioplasty: successful treatment with a covered stent-graft. Rasmus M; Huegli R; Jacob AL; Aschwanden M; Bilecen D Cardiovasc Intervent Radiol; 2007; 30(3):497-500. PubMed ID: 17225968 [TBL] [Abstract][Full Text] [Related]
13. Initial findings and potential applicability of computational simulation of the aorta in acute type B dissection. Cheng Z; Riga C; Chan J; Hamady M; Wood NB; Cheshire NJ; Xu Y; Gibbs RG J Vasc Surg; 2013 Feb; 57(2 Suppl):35S-43S. PubMed ID: 23336853 [TBL] [Abstract][Full Text] [Related]
14. Endovascular stent-graft placement for the treatment of acute aortic dissection. Dake MD; Kato N; Mitchell RS; Semba CP; Razavi MK; Shimono T; Hirano T; Takeda K; Yada I; Miller DC N Engl J Med; 1999 May; 340(20):1546-52. PubMed ID: 10332016 [TBL] [Abstract][Full Text] [Related]
15. Percutaneous insertion of a jacketed stent to close the entry of dissecting aortic aneurysms of DeBakey types I and II. Karube N; Noishiki Y; Yamamoto K; Kondo J; Matsumoto A Artif Organs; 1993 Dec; 17(12):1004-9. PubMed ID: 8110066 [TBL] [Abstract][Full Text] [Related]
16. [Percutaneous placement of intraluminal stent-graft for aortic dissection: experimental study]. Hashimoto M; Sawada S; Morioka N; Kotani K; Iwamiya T; Senda T; Tanigawa N; Kobayashi M; Okuda Y; Ohta Y Nihon Igaku Hoshasen Gakkai Zasshi; 1995 Nov; 55(14):939-45. PubMed ID: 8570388 [TBL] [Abstract][Full Text] [Related]
17. Application of protective stents in endovascular repair of acute complicated Stanford type B aortic dissections. Liu JF; Jiang WL; Lu HT; Li YL; Zhang TH; Yamakawa T J Endovasc Ther; 2013 Apr; 20(2):210-8. PubMed ID: 23581765 [TBL] [Abstract][Full Text] [Related]
18. Treatment of acute aortic type B dissection with stent-grafts. Hausegger KA; Tiesenhausen K; Schedlbauer P; Oberwalder P; Tauss J; Rigler B Cardiovasc Intervent Radiol; 2001; 24(5):306-12. PubMed ID: 11815835 [TBL] [Abstract][Full Text] [Related]
19. Scheduled re-entry coil embolization before entry coverage of thoracic endovascular stent grafting for aneurysmal chronic type B aortic dissection. Katayama K; Uchida N; Takahashi S; Sueda T Interact Cardiovasc Thorac Surg; 2012 Oct; 15(4):800-1. PubMed ID: 22821649 [TBL] [Abstract][Full Text] [Related]
20. Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design. Sobocinski J; Lombardi JV; Dias NV; Berger L; Zhou Q; Jia F; Resch T; Haulon S J Vasc Surg; 2016 May; 63(5):1216-24. PubMed ID: 26806523 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]