These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 787547)

  • 21. Estimation of cardiac output in the horse by thermodilution techniques.
    Muir WW; Skarda RT; Milne DW
    Am J Vet Res; 1976 Jun; 37(6):697-700. PubMed ID: 779541
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Determinants of variation between Fick and indicator dilution estimates of cardiac output during diagnostic catheterization. Fick vs. dye cardiac outputs.
    Reddy PS; Curtiss EI; Bell B; O'Toole JD; Salerni R; Leon DF; Shaver JA
    J Lab Clin Med; 1976 Apr; 87(4):568-76. PubMed ID: 775003
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method.
    Engoren M; Barbee D
    Am J Crit Care; 2005 Jan; 14(1):40-5. PubMed ID: 15608107
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison between the thermal dilution method and the direct Fick and the dye dilution methods for cardiac output measurements in man.
    Enghoff E; Michaëlsson M; Pavek K; Sjögren S
    Acta Soc Med Ups; 1970; 75(3-4):157-70. PubMed ID: 4941433
    [No Abstract]   [Full Text] [Related]  

  • 25. [Correlation of clinical, hemodynamic and biological data at the acute stage of myocardial infarction].
    Kahn JC; Melman S; Epois A; Roudy G; Bourdarias JP; Mathivat A
    Arch Mal Coeur Vaiss; 1973 May; 66(5):609-21. PubMed ID: 4199978
    [No Abstract]   [Full Text] [Related]  

  • 26. [Determination of the cardiac output by the dye dilution method using oximeter and continuous recording in comparison to Fick principle].
    Ansari MA; Porstmann W; Günther KH; Wierny L
    Dtsch Gesundheitsw; 1966 Jan; 21(4):176-82. PubMed ID: 5328962
    [No Abstract]   [Full Text] [Related]  

  • 27. Circulatory effects of acute myocardial infarction as a rational basis for therapy.
    Resnekov L; Lipp H
    Ann Clin Res; 1971 Dec; 3(6):362-76. PubMed ID: 4945364
    [No Abstract]   [Full Text] [Related]  

  • 28. [Determination of the indicators of stroke volume by the methods of dye dilution and echocardiography in mycardial infarct].
    Golyshnikov VA; Kutsenko AI
    Kardiologiia; 1976 Jun; 16(6):101-4. PubMed ID: 799182
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Some comments on the usefulness of measuring cardiac output by dye dilution.
    de Leeuw PW; Birkenhäger WH
    Eur Heart J; 1990 Dec; 11 Suppl I():13-6. PubMed ID: 2092982
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Comparative analysis of cardiac output determined by thermodilution, dye dilution and an impedance method in clinical application].
    Feng JZ
    Zhonghua Nei Ke Za Zhi; 1982 Sep; 21(9):533-5. PubMed ID: 6759072
    [No Abstract]   [Full Text] [Related]  

  • 31. A simplified procedure for the calculation of cardiac output from dye dilution curves.
    Jorfeldt L; Wahren J
    Acta Med Scand Suppl; 1967; 472():75-80. PubMed ID: 5340988
    [No Abstract]   [Full Text] [Related]  

  • 32. Earpiece dye dilution technique as a method for evaluation of haemodynamic changes during standardized effort test.
    Zochowski RJ; Serzysko W
    Cor Vasa; 1971; 13(1):50-63. PubMed ID: 4935543
    [No Abstract]   [Full Text] [Related]  

  • 33. Computer measurement of cardiac output by dye dilution: comparison of computer, Fick, and Dow techniques.
    Stenson R; Crouse L; Harrison DC
    Cardiovasc Res; 1972 Jul; 6(4):449-56. PubMed ID: 4558157
    [No Abstract]   [Full Text] [Related]  

  • 34. Comparison of Fick and thermodilution cardiac output determinations in standing horses.
    Lépiz ML; Keegan RD; Bayly WM; Greene SA; McEwen MM
    Res Vet Sci; 2008 Oct; 85(2):307-14. PubMed ID: 18093624
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Quasi-simultaneous cardiac output determinations in dogs with the direct Fick method (O2 and CO2) and with the dye dilution method using a linear reflection densitometer.
    ten Hoor F; Rispens P; Buursma A; Fongers TM; Jurriëns JM; Zijlma JA
    Pflugers Arch; 1970; 314(2):148-50. PubMed ID: 4903732
    [No Abstract]   [Full Text] [Related]  

  • 36. Effects of ouabain on impaired left ventricular function in acute myocardial infarction.
    Rahimtoola SH; Sinno MZ; Chuquimia R; Loeb HS; Rosen KM; Gunnar RM
    N Engl J Med; 1972 Sep; 287(11):527-31. PubMed ID: 4559121
    [No Abstract]   [Full Text] [Related]  

  • 37. Measurement of stroke volume by the vibrocardiogram.
    Agress CM; Wegner S; Fremont RP; Mori I; Day DJ
    Aerosp Med; 1967 Dec; 38(12):1248-52. PubMed ID: 4864848
    [No Abstract]   [Full Text] [Related]  

  • 38. Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique.
    Hofer CK; Bühlmann S; Klaghofer R; Genoni M; Zollinger A
    Acta Anaesthesiol Scand; 2004 May; 48(5):653-7. PubMed ID: 15101865
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Cardiac output in acute myocardial infarction. Serial determination by precordial radioisotope dilution curves.
    MURPHY GW; GLICK G; SCHREINER BF; YU PN
    Am J Cardiol; 1963 May; 11():587-93. PubMed ID: 13936737
    [No Abstract]   [Full Text] [Related]  

  • 40. Effect of posture on cardiac output after myocardial infarction.
    Groden BM
    Br Heart J; 1969 Nov; 31(6):735-40. PubMed ID: 4902088
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.