BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 7877564)

  • 1. Clinical hemolysis with the St. Jude heart valve without paravalvular leak.
    Barmada H; Starr A
    Med Prog Technol; 1994; 20(3-4):191-4. PubMed ID: 7877564
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Renal hemosiderosis caused by chronic hemolysis in a patient with a Saint-Jude mitral valve prosthesis].
    Somody E; Ferrières J; Dumazer P; Mignon-Conte M; Galinier F; Bernadet P
    Arch Mal Coeur Vaiss; 1993 Jan; 86(1):111-3. PubMed ID: 8338395
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Severe hemolytic anemia following purse-string valvuloplasty of the mitral valve].
    Brand B; Althaus U; Bucher U
    Schweiz Med Wochenschr; 1990 Mar; 120(13):456-61. PubMed ID: 2183349
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surface analysis of bileaflet prosthetic heart valve leaflet leading edge.
    Barmada H; Cohen D
    ASAIO J; 1998; 44(4):294-8. PubMed ID: 9682955
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Erythropoietin can obviate the need for repeated heart valve replacement in high-risk patients with severe mechanical hemolytic anemia: case reports and literature review.
    Shapira Y; Bairey O; Vatury M; Magen-Nativ H; Prokocimer M; Sagie A
    J Heart Valve Dis; 2001 Jul; 10(4):431-5. PubMed ID: 11499585
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemolysis after mitral valve repair: a report of five cases and literature review.
    Demirsoy E; Yilmaz O; Sirin G; Baran T; Tekin S; Sener D; Sonmez B
    J Heart Valve Dis; 2008 Jan; 17(1):24-30. PubMed ID: 18365565
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Single-center outcome analysis of 1,161 patients with St. Jude medical and ATS open pivot mechanical heart valves.
    Bernet FH; Baykut D; Grize L; Zerkowski HR
    J Heart Valve Dis; 2007 Mar; 16(2):151-8. PubMed ID: 17484464
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Hemolytic anemia as a result of hemodynamically-insignificant paravalvular dehiscence of St. Jude-Medical aortic valve prosthesis].
    Horstkotte D; Pippert H; Körfer R; Bircks W; Loogen F
    Z Kardiol; 1986 Aug; 75(8):502-4. PubMed ID: 3776290
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prosthetic heart valves with silver-coated sewing cuff fabric: early morphological features in two patients.
    Butany J; Scully HE; VanArsdell G; Leask R
    Can J Cardiol; 2002 Jul; 18(7):733-8. PubMed ID: 12167960
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Serious hemolytic anemia after mitral valvuloplasty].
    Michlmayr G; Knapp E; Scharfetter H; Simma HP; Braunsteiner H
    Acta Med Austriaca; 1979; 6(5):195-7. PubMed ID: 555215
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Chronic hemolysis after a mechanical valve replacement in a comparative study between the St. Jude Medical valve and the omniscience valve prosthesis].
    Chiba Y; Ishihara H; Ihaya A; Kobayashi A; Akita T; Muraoka R; Yamasato A; Tatsuta N
    Nihon Kyobu Geka Gakkai Zasshi; 1987 Feb; 35(2):161-8. PubMed ID: 3585085
    [No Abstract]   [Full Text] [Related]  

  • 12. Hemolytic anemia following insertion of Ionescu-Shiley mitral valve bioprosthesis.
    Reddy SB; Pater JL; Pym J; Armstrong PW
    Can Med Assoc J; 1984 Dec; 131(12):1469-70. PubMed ID: 6498703
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A case of failure of mitroflow pericardial valve with severe hemolytic anemia].
    Ohkado A; Akiyama K; Hirota J; Shiina Y
    Kyobu Geka; 1995 Nov; 48(12):1013-5. PubMed ID: 8538101
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Hemolysis after bioprosthesis implantation in the mitral valve].
    Olszowska M; Hlawaty M; Pfitzner R; Tracz W
    Pol Tyg Lek; 1993 Jan 18-25; 48(3-4):83-4. PubMed ID: 8361896
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Severe hemolytic anemia after mitral valvuloplasty].
    Michlmayr G; Knapp E; Scharfetter H; Simma HP; Gschnitzer F
    Schweiz Med Wochenschr; 1979 Jun; 109(26):976-8. PubMed ID: 462165
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intractable hemolysis caused by perivalvular leakage following mitral valve replacement with St. Jude Medical prosthesis.
    Okita Y; Miki S; Kusuhara K; Ueda Y; Tahata T; Tsukamoto Y; Yamanaka K; Shiraishi S
    Ann Thorac Surg; 1988 Jul; 46(1):89-92. PubMed ID: 3289520
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Repair of paravalvular leak after a third mitral valve replacement].
    Aizawa K; Tateishi A; Sakano Y; Kaminishi Y; Ohki S; Saito T; Konishi H; Kawada M; Misawa Y
    Kyobu Geka; 2007 Sep; 60(10):903-5. PubMed ID: 17877009
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does the morphology of mitral paravalvular leaks influence symptoms and hemolysis?
    Genoni M; Franzen D; Tavakoli R; Seiffert B; Graves K; Jenni R; Turina M
    J Heart Valve Dis; 2001 Jul; 10(4):426-30. PubMed ID: 11499584
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Twenty-year comparison of tissue and mechanical valve replacement.
    Khan SS; Trento A; DeRobertis M; Kass RM; Sandhu M; Czer LS; Blanche C; Raissi S; Fontana GP; Cheng W; Chaux A; Matloff JM
    J Thorac Cardiovasc Surg; 2001 Aug; 122(2):257-69. PubMed ID: 11479498
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Silzone-coated St. Jude medical valve: a safe valve.
    Houël R; Kirsch M; Hillion ML; Loisance D
    J Heart Valve Dis; 2001 Nov; 10(6):724-7. PubMed ID: 11767177
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.