138 related articles for article (PubMed ID: 7882733)
1. Effect of internal fixation plates on microcirculation in under-plate cortical bones. Microangiography and scanning electronmicroscopy.
Wang Y; Dai KR
Chin Med J (Engl); 1994 Dec; 107(12):929-33. PubMed ID: 7882733
[TBL] [Abstract][Full Text] [Related]
2. [Morphological study of the microcirculation in regional cortical bones affected by internal fixation plates].
Wang Y
Zhonghua Wai Ke Za Zhi; 1993 Apr; 31(4):248-50. PubMed ID: 8275846
[TBL] [Abstract][Full Text] [Related]
3. Bone remodelling after internal fixation with different stiffness plates: ultrastructural investigation.
Chen YQ; Dai KR; Qiu SJ; Zhu ZA
Chin Med J (Engl); 1994 Oct; 107(10):766-70. PubMed ID: 7835104
[TBL] [Abstract][Full Text] [Related]
4. [Experimental study on plates of various stiffness--on their effects on the bones and rigidity in fracture immobilization].
Yoshida K
Nihon Seikeigeka Gakkai Zasshi; 1982 Aug; 56(8):739-51. PubMed ID: 7153609
[TBL] [Abstract][Full Text] [Related]
5. [Bone remodeling after internal fixation with different stiffness plates: ultrastructural investigation].
Chen YQ
Zhonghua Wai Ke Za Zhi; 1991 Apr; 29(4):256-9, 272. PubMed ID: 1874119
[TBL] [Abstract][Full Text] [Related]
6. A comparison of cortical bone atrophy secondary to fixation with plates with large differences in bending stiffness.
Woo SL; Akeson WH; Coutts RD; Rutherford L; Doty D; Jemmott GF; Amiel D
J Bone Joint Surg Am; 1976 Mar; 58(2):190-5. PubMed ID: 1254623
[TBL] [Abstract][Full Text] [Related]
7. Less rigid internal fixation plates: historical perspectives and new concepts.
Woo SL; Lothringer KS; Akeson WH; Coutts RD; Woo YK; Simon BR; Gomez MA
J Orthop Res; 1984; 1(4):431-49. PubMed ID: 6491792
[TBL] [Abstract][Full Text] [Related]
8. Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.
Jain R; Podworny N; Hearn T; Anderson GI; Schemitsch EH
J Orthop Trauma; 1997 Oct; 11(7):490-5. PubMed ID: 9334950
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical and biological aspects of defect treatment in fractures using helical plates.
Perren SM; Regazzoni P; Fernandez AA
Acta Chir Orthop Traumatol Cech; 2014; 81(4):267-71. PubMed ID: 25137496
[TBL] [Abstract][Full Text] [Related]
10. The influence of different degrees of stiffness of fixation plates on experimental bone healing.
Terjesen T; Apalset K
J Orthop Res; 1988; 6(2):293-9. PubMed ID: 3343634
[TBL] [Abstract][Full Text] [Related]
11. [The structural changes of cortical bone beneath plate after rigid platefixation and removal].
Zhu Z; Dai K; Qiu S
Zhonghua Wai Ke Za Zhi; 1997 Jul; 35(7):418-20. PubMed ID: 10677976
[TBL] [Abstract][Full Text] [Related]
12. Quantitative histological evaluation of early fracture healing of cortical bones immobilized by stainless steel and composite plates.
Akeson WH; Woo SL; Coutts RD; Matthews JV; Gonsalves M; Amiel D
Calcif Tissue Res; 1975 Nov; 19(1):27-37. PubMed ID: 1201463
[TBL] [Abstract][Full Text] [Related]
13. A metallurgical examination of fractured stainless-steel ASIF tibial plates.
Richman MH; Weltman JK; Cole A
Injury; 1976 Aug; 8(1):13-9. PubMed ID: 1002271
[TBL] [Abstract][Full Text] [Related]
14. Atrophy of cortical bone caused by rigid internal fixation plates. An experimental study in the dog.
Strömberg L; Dalén N
Acta Orthop Scand; 1978 Oct; 49(5):448-56. PubMed ID: 707056
[TBL] [Abstract][Full Text] [Related]
15. [Ultrastructural investigation of experimental fracture healing: effect of fixation with plates of various materials].
Qiu SJ
Zhonghua Wai Ke Za Zhi; 1990 Feb; 28(2):88-91, 126. PubMed ID: 2364831
[TBL] [Abstract][Full Text] [Related]
16. [An experimental study of the effects of stress-relaxation plate on bone remodeling].
Dai M; Dai K; Qui S
Zhonghua Wai Ke Za Zhi; 1995 Nov; 33(11):698-700. PubMed ID: 8731919
[TBL] [Abstract][Full Text] [Related]
17. Cortical bone perfusion in plated fractured sheep tibiae.
Kregor PJ; Senft D; Parvin D; Campbell C; Toomey S; Parker C; Gillespy T; Swiontkowski MF
J Orthop Res; 1995 Sep; 13(5):715-24. PubMed ID: 7472750
[TBL] [Abstract][Full Text] [Related]
18. Quantitative microradiography of cortical bone in disuse osteoporosis following fracture fixation.
Williams DF; Gore LF; Clark GC
Biomaterials; 1983 Oct; 4(4):285-8. PubMed ID: 6640055
[TBL] [Abstract][Full Text] [Related]
19. Radiographic abnormalities in tubular bone after rigid plate fixation in rabbits.
Paavolainen P; Karaharju E; Slätis P
Acta Radiol Diagn (Stockh); 1978; 19(1A):119-26. PubMed ID: 646875
[TBL] [Abstract][Full Text] [Related]
20. Bone ingrowth and stress shielding with a porous surface coated fracture fixation plate.
Pilliar RM; Cameron HU; Binnington AG; Szivek J; Macnab I
J Biomed Mater Res; 1979 Sep; 13(5):799-810. PubMed ID: 383716
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]