72 related articles for article (PubMed ID: 7901977)
1. [Computerized sonometry--use of a noninvasive procedure for evaluating stability after fractures].
Fellinger M; Schanner A; Szyszkowitz R; Leitgeb N; Stockenhuber N; Roupec R
Aktuelle Traumatol; 1993 Aug; 23(5):235-8. PubMed ID: 7901977
[TBL] [Abstract][Full Text] [Related]
2. Early detection of delayed union in lower leg fractures using a computerised analysis of mechanical vibration reactions of bone for assessing the state of fracture healing.
Fellinger M; Leitgeb N; Szyszkowitz R; Peicha G; Passler J; Seggl W; Schanner A
Arch Orthop Trauma Surg; 1994; 113(2):93-6. PubMed ID: 8186056
[TBL] [Abstract][Full Text] [Related]
3. Efficacy of monitoring long-bone fracture healing by measurement of either bone stiffness or resonant frequency: numerical simulation.
Roberts SG; Steele CR
J Orthop Res; 2000 Sep; 18(5):691-7. PubMed ID: 11117288
[TBL] [Abstract][Full Text] [Related]
4. External fixation of tibial pilon fractures and fracture healing.
Ristiniemi J
Acta Orthop Suppl; 2007 Jun; 78(326):3, 5-34. PubMed ID: 17465283
[TBL] [Abstract][Full Text] [Related]
5. Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression.
Aro HT; Chao EY
Clin Orthop Relat Res; 1993 Aug; (293):8-17. PubMed ID: 8339513
[TBL] [Abstract][Full Text] [Related]
6. Quantitative assessment of fracture healing. The value of computerised sonometry in a correlative animal experiment in sheep.
Fellinger M; Peicha G; Eschberger J; Seggl W; Passler JM; Ranner G; Leitgeb N
Arch Orthop Trauma Surg; 1994; 113(6):337-44. PubMed ID: 7833213
[TBL] [Abstract][Full Text] [Related]
7. The initial phase of fracture healing is specifically sensitive to mechanical conditions.
Klein P; Schell H; Streitparth F; Heller M; Kassi JP; Kandziora F; Bragulla H; Haas NP; Duda GN
J Orthop Res; 2003 Jul; 21(4):662-9. PubMed ID: 12798066
[TBL] [Abstract][Full Text] [Related]
8. [Tractive force measurement in bone transport--an in vivo investigation in humans].
Baumgart R; Kuhn V; Hinterwimmer S; Krammer M; Mutschler W
Biomed Tech (Berl); 2004 Sep; 49(9):248-56. PubMed ID: 15493133
[TBL] [Abstract][Full Text] [Related]
9. Three-dimensional load measurements in an external fixator.
Seide K; Weinrich N; Wenzl ME; Wolter D; Jürgens C
J Biomech; 2004 Sep; 37(9):1361-9. PubMed ID: 15275843
[TBL] [Abstract][Full Text] [Related]
10. Pressure, oxygen tension and temperature in the periosteal callus during bone healing--an in vivo study in sheep.
Epari DR; Lienau J; Schell H; Witt F; Duda GN
Bone; 2008 Oct; 43(4):734-9. PubMed ID: 18634913
[TBL] [Abstract][Full Text] [Related]
11. Load transmission through a healing tibial fracture.
Vijayakumar V; Marks L; Bremmer-Smith A; Hardy J; Gardner T
Clin Biomech (Bristol, Avon); 2006 Jan; 21(1):49-53. PubMed ID: 16226358
[TBL] [Abstract][Full Text] [Related]
12. Stiffness measurement of the neocallus with the Fraktometer FM 100.
Schmickal T; von Recum J; Wentzensen A
Arch Orthop Trauma Surg; 2005 Dec; 125(10):653-9. PubMed ID: 16189688
[TBL] [Abstract][Full Text] [Related]
13. Weight bearing after tibial fracture as a guide to healing.
Joslin CC; Eastaugh-Waring SJ; Hardy JR; Cunningham JL
Clin Biomech (Bristol, Avon); 2008 Mar; 23(3):329-33. PubMed ID: 17997205
[TBL] [Abstract][Full Text] [Related]
14. Differential regulation of blood vessel formation between standard and delayed bone healing.
Lienau J; Schmidt-Bleek K; Peters A; Haschke F; Duda GN; Perka C; Bail HJ; Schütze N; Jakob F; Schell H
J Orthop Res; 2009 Sep; 27(9):1133-40. PubMed ID: 19274756
[TBL] [Abstract][Full Text] [Related]
15. Noninvasive monitoring techniques for quantitative description of callus mineral content and mechanical properties.
Markel MD; Chao EY
Clin Orthop Relat Res; 1993 Aug; (293):37-45. PubMed ID: 8339505
[TBL] [Abstract][Full Text] [Related]
16. [Segmental tibia fractures: a critical retrospective analysis of 49 cases].
Bonnevialle P; Cariven P; Bonnevialle N; Mansat P; Martinel V; Verhaeghe L; Mansat M
Rev Chir Orthop Reparatrice Appar Mot; 2003 Sep; 89(5):423-32. PubMed ID: 13679742
[TBL] [Abstract][Full Text] [Related]
17. [Biomechanics of external fixation devices and optimal tactics for treating long bone fractures].
Karlov AV; Lichatschov VN
Biomed Tech (Berl); 1997; 42 Suppl():89-90. PubMed ID: 9517060
[No Abstract] [Full Text] [Related]
18. Local anabolic effects of growth hormone on intact bone and healing fractures in rats.
Andreassen TT; Oxlund H
Calcif Tissue Int; 2003 Sep; 73(3):258-64. PubMed ID: 14667139
[TBL] [Abstract][Full Text] [Related]
19. Tibial external fixation, weight bearing, and fracture movement.
Kershaw CJ; Cunningham JL; Kenwright J
Clin Orthop Relat Res; 1993 Aug; (293):28-36. PubMed ID: 8339493
[TBL] [Abstract][Full Text] [Related]
20. [In vivo measurements of electric potentials of the Ilisarov external fixator].
Müller S; Wolter D; ter Haseborg JL
Unfallchirurg; 1992 Nov; 95(11):588-92. PubMed ID: 1480976
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]