BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 7910179)

  • 1. In-hospital evaluation of orthophthalaldehyde as a high level disinfectant for flexible endoscopes.
    Alfa MJ; Sitter DL
    J Hosp Infect; 1994 Jan; 26(1):15-26. PubMed ID: 7910179
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficiency of the glutaraldehyde test strip for monitoring the concentration of glutaraldehyde in reused solutions for disinfecting endoscopes.
    Keerasuntonpong A; Sitaposa P; Chaiprasert A; Thamlikitkul V
    J Med Assoc Thai; 2002 Nov; 85(11):1164-8. PubMed ID: 12546312
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microbial bioburden in endoscope reprocessing and an in-use evaluation of the high-level disinfection capabilities of Cidex PA.
    Vesley D; Melson J; Stanley P
    Gastroenterol Nurs; 1999; 22(2):63-8. PubMed ID: 10382415
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sporicidal activity of disinfectants as one possible cause for bacteria in patient-ready endoscopes.
    Miner N; Harris V; Ebron T; Cao TD
    Gastroenterol Nurs; 2007; 30(4):285-90. PubMed ID: 17724404
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Longitudinal assessment of reprocessing effectiveness for colonoscopes and gastroscopes: Results of visual inspections, biochemical markers, and microbial cultures.
    Ofstead CL; Wetzler HP; Heymann OL; Johnson EA; Eiland JE; Shaw MJ
    Am J Infect Control; 2017 Feb; 45(2):e26-e33. PubMed ID: 28159069
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning.
    Alfa MJ; Degagne P; Olson N
    Am J Infect Control; 1999 Oct; 27(5):392-401. PubMed ID: 10511485
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Persistent contamination on colonoscopes and gastroscopes detected by biologic cultures and rapid indicators despite reprocessing performed in accordance with guidelines.
    Ofstead CL; Wetzler HP; Doyle EM; Rocco CK; Visrodia KH; Baron TH; Tosh PK
    Am J Infect Control; 2015 Aug; 43(8):794-801. PubMed ID: 26234219
    [TBL] [Abstract][Full Text] [Related]  

  • 8. EVOTECH endoscope cleaner and reprocessor (ECR) simulated-use and clinical-use evaluation of cleaning efficacy.
    Alfa MJ; DeGagne P; Olson N; Fatima I
    BMC Infect Dis; 2010 Jul; 10():200. PubMed ID: 20618935
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enteroviruses, endoscopy and infection control: an applied study.
    Hanson PJ; Bennett J; Jeffries DJ; Collins JV
    J Hosp Infect; 1994 May; 27(1):61-7. PubMed ID: 7916364
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Disinfection of rigid nasal endoscopes following in vitro contamination with Staphylococcus aureus, Streptococcus pneumoniae, Pseudomonas aeruginosa, and Haemophilus influenzae.
    Bradford BD; Seiberling KA; Park FE; Hiebert JC; Chang DF
    JAMA Otolaryngol Head Neck Surg; 2013 Jun; 139(6):574-8. PubMed ID: 23680971
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated washing with the Reliance Endoscope Processing System and its equivalence to optimal manual cleaning.
    Alfa MJ; Olson N; DeGagne P
    Am J Infect Control; 2006 Nov; 34(9):561-70. PubMed ID: 17097450
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endoscope decontamination: a comparison of the Wolf 35100 and DSD-91 systems.
    Corcoran GD; Holton J; Ridgway GL
    J Hosp Infect; 1994 Aug; 27(4):307-15. PubMed ID: 7963473
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-level disinfection of cystoscopic equipment with ortho-phthalaldehyde solution.
    Hamasuna R; Nose K; Sueyoshi T; Nagano M; Hasui Y; Osada Y; Hamasuna R
    J Hosp Infect; 2004 Aug; 57(4):346-8. PubMed ID: 15262398
    [No Abstract]   [Full Text] [Related]  

  • 14. An evaluation of Cidex OPA (0.55% ortho-phthalaldehyde) as an alternative to 2% glutaraldehyde for high-level disinfection of endoscopes.
    Cooke RP; Goddard SV; Whymant-Morris A; Sherwood J; Chatterly R
    J Hosp Infect; 2003 Jul; 54(3):226-31. PubMed ID: 12855240
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the antimicrobial activity and materials compatibility of orthophthalaldehyde as a high-level disinfectant.
    Akamatsu T; Minemoto M; Uyeda M
    J Int Med Res; 2005; 33(2):178-87. PubMed ID: 15790129
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The truth and consequences of enzymatic detergents.
    Hutchisson B; LeBlanc C
    Gastroenterol Nurs; 2005; 28(5):372-6. PubMed ID: 16234633
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On-site comparison of an enzymatic detergent and a non-enzymatic detergent-disinfectant for routine manual cleaning of flexible endoscopes.
    Gonzalez JA; Vanzieleghem T; Dumazy A; Meuris C; Mutsers J; Christiaens G; Leclercq P; Loly JP; Louis E; Gast P
    Endosc Int Open; 2019 Apr; 7(4):E412-E420. PubMed ID: 30931371
    [No Abstract]   [Full Text] [Related]  

  • 18. Risk of contamination of sterile biopsy forceps in disinfected endoscopes.
    Lee RM; Kozarek RA; Sumida SE; Raltz SL
    Gastrointest Endosc; 1998 May; 47(5):377-81. PubMed ID: 9609430
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The validity of adenosine triphosphate measurement in detecting endoscope contamination.
    McCafferty CE; Abi-Hanna D; Aghajani MJ; Micali GT; Lockart I; Vickery K; Gosbell IB; Jensen SO
    J Hosp Infect; 2018 Nov; 100(3):e142-e145. PubMed ID: 30092293
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of 12-Week Shelf Life of Patient-Ready Endoscopes.
    Lacey V; Good K; Toliver C; Jenkins S; DeGuzman PB
    Gastroenterol Nurs; 2019; 42(2):159-164. PubMed ID: 30946303
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.