These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

59 related articles for article (PubMed ID: 7914143)

  • 1. Cerebral reserve and indications for shunting in carotid surgery.
    Palombo D; Porta C; Peinetti F; Brustia P; Udini M; Antico A; Cantalupi D; Varetto T
    Cardiovasc Surg; 1994 Feb; 2(1):32-6. PubMed ID: 7914143
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Hemodynamic reserve in carotid surgery and the use of "superselective" shunt].
    Palombo D; Porta C; Peinetti F; Brustia P; Udini M; Antico A; Carmonini A; Cantalupi D; Varetto T
    Minerva Chir; 1992 Oct; 47(20):1589-94. PubMed ID: 1480283
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Impaired cerebral autoregulation in asymptomatic patients with carotid artery stenosis: comparison of acetazolamide-SPECT and transcranial CO(2)-dopplersonography].
    Engelhardt M; Pfadenhauer K; Zentner J; Grimmer S; Wachenfeld-Wahl C; Heidenreich P; Loeprecht H; Wölfle KD
    Zentralbl Chir; 2004 Jun; 129(3):178-82. PubMed ID: 15237321
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Cerebral ischemia during carotid clamping: diagnosis and prevention].
    Lang W; Dinkel M
    Zentralbl Chir; 2000; 125(3):243-50. PubMed ID: 10769444
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cerebral hyperperfusion after carotid endarterectomy is associated with preoperative hemodynamic impairment and intraoperative cerebral ischemia.
    Komoribayashi N; Ogasawara K; Kobayashi M; Saitoh H; Terasaki K; Inoue T; Ogawa A
    J Cereb Blood Flow Metab; 2006 Jul; 26(7):878-84. PubMed ID: 16280980
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials.
    Moritz S; Kasprzak P; Arlt M; Taeger K; Metz C
    Anesthesiology; 2007 Oct; 107(4):563-9. PubMed ID: 17893451
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Cerebral haemodynamics during carotid angioplasty with flow interruption. The correlation between oximetry and transcranial Doppler ultrasonography].
    Cañibano-Domínguez C; Acín F; Bueno-Bertomeu A; Bleda-Moreno S; Gómez-Penas M; López-Quintana A
    Rev Neurol; 2010 Aug; 51(3):146-52. PubMed ID: 20645265
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Selective shunting based on somatosensory evoked potential monitoring during carotid endarterectomy.
    Amantini A; De Scisciolo G; Bartelli M; Lori S; Ronchi O; Pratesi C; Bertini D; Pinto F
    Int Angiol; 1987; 6(4):387-90. PubMed ID: 3450755
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Somatosensory evoked potentials and biochemical markers of neuronal deficits in patients undergoing carotid endarterectomy under regional anesthesia].
    Schneemilch CE; Ludwig S; Ulrich A; Halloul Z; Hachenberg T
    Zentralbl Chir; 2007 Jun; 132(3):176-82. PubMed ID: 17610185
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A clinical evaluation of near-infrared cerebral oximetry in the awake patient to monitor cerebral perfusion during carotid endarterectomy.
    Rigamonti A; Scandroglio M; Minicucci F; Magrin S; Carozzo A; Casati A
    J Clin Anesth; 2005 Sep; 17(6):426-30. PubMed ID: 16171662
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Regional cerebral saturation versus transcranial Doppler during carotid endarterectomy under regional anaesthesia.
    Pugliese F; Ruberto F; Tosi A; Martelli S; Bruno K; Summonti D; D'Alio A; Diana B; Anile M; Panico A; Speziale F; Pietropaoli P
    Eur J Anaesthesiol; 2009 Aug; 26(8):643-7. PubMed ID: 19494780
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Update on cerebral monitoring and protective methods].
    Pistolese GR; Appolloni A; Ronchey S; Marciani MG; De Simone R; Sabato A
    Ann Ital Chir; 1997; 68(4):441-51. PubMed ID: 9494173
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Obstructive carotid and/or intracranial artery disease rarely affects the incidence of haemodynamic ischaemic stroke during cardiac surgery: a study on brain perfusion single-photon emission computed tomography with acetazolamide.
    Imasaka K; Yasaka M; Tayama E; Tomita Y
    Eur J Cardiothorac Surg; 2015 Nov; 48(5):739-46. PubMed ID: 25549991
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The use of preoperative transcranial Doppler variables to predict which patients do not need a shunt during carotid endarterectomy.
    Visser GH; Wieneke GH; van Huffelen AC; Eikelboom BC
    Eur J Vasc Endovasc Surg; 2000 Mar; 19(3):226-32. PubMed ID: 10753684
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cerebral monitoring during carotid endarterectomy--a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure.
    Botes K; Le Roux DA; Van Marle J
    S Afr J Surg; 2007 May; 45(2):43-6. PubMed ID: 17674560
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review.
    Pennekamp CW; Bots ML; Kappelle LJ; Moll FL; de Borst GJ
    Eur J Vasc Endovasc Surg; 2009 Nov; 38(5):539-45. PubMed ID: 19665397
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Comprehensive monitoring of cerebral haemodynamics during surgical interventions on brachiocephalic arteries].
    Ignat'ev IM; Bredikhin RA; Falina TG; Vinogradova VV; Khismatullina LI
    Angiol Sosud Khir; 2010; 16(3):107-11. PubMed ID: 21280300
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intraoperative assessment of cerebral ischaemia during carotid surgery.
    Pedrini L; Tarantini S; Cirelli MR; Ballester A; Cifiello BI; D'Addato M
    Int Angiol; 1998 Mar; 17(1):10-4. PubMed ID: 9657241
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Neuromonitoring in carotid surgery: are the results obtained in awake patients transferable to patients under sevoflurane/fentanyl anesthesia?
    Moritz S; Schmidt C; Bucher M; Wiesenack C; Zimmermann M; Schebesch KM; Kasprzak P; Metz C
    J Neurosurg Anesthesiol; 2010 Oct; 22(4):288-95. PubMed ID: 20479662
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Shaking limb transient ischemic attacks: unusual presentation of carotid artery occlusive disease: report of two cases.
    Klempen NL; Janardhan V; Schwartz RB; Stieg PE
    Neurosurgery; 2002 Aug; 51(2):483-7; discussion 487. PubMed ID: 12182788
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.