These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
85 related articles for article (PubMed ID: 7920202)
1. CAE software for the noninvasive diagnosis method on the atherosclerosis by ultrasonic Doppler effect. Sasaki S; Yokobori AT; Ohkuma T Biomed Mater Eng; 1994; 4(2):97-103. PubMed ID: 7920202 [TBL] [Abstract][Full Text] [Related]
2. Algorithm of the noninvasive diagnosis method on the atherosclerosis by ultrasonic Doppler effect. Yokobori AT; Ohkuma T; Sasaki S; Yoshinari H; Yokobori T; Ohuchi H; Mori S Biomed Mater Eng; 1994; 4(2):87-96. PubMed ID: 7920201 [TBL] [Abstract][Full Text] [Related]
3. Theoretical foundation on a noninvasive estimation for viscoelastic mechanical property of blood vessels by ultrasonic Doppler effect. Yoshinari H; Yokobori AT; Ohkuma T Biomed Mater Eng; 1994; 4(2):77-86. PubMed ID: 7920200 [TBL] [Abstract][Full Text] [Related]
4. Acoustical imaging and processing of blood vessel and the related materials using ultrasound Doppler effect. Yokobori AT; Ohkuma T; Yoshinari H; Yokobori T; Ohuchi H; Mori S Biomed Mater Eng; 1991; 1(2):127-36. PubMed ID: 1364631 [TBL] [Abstract][Full Text] [Related]
5. The proposal of noninvasive quantitative diagnostic method of the atherosclerosis and the clarification of organ correlation of atherosclerosis and oxygen metabolism. Yokobori AT; Ichiki M; Ohuchi H; Kobayashi T; Satoh T; Kinoshita Y Biomed Mater Eng; 2004; 14(3):241-9. PubMed ID: 15299236 [TBL] [Abstract][Full Text] [Related]
6. Estimation of the viscoelastic properties of vessel walls using a computational model and Doppler ultrasound. Balocco S; Basset O; Courbebaisse G; Boni E; Frangi AF; Tortoli P; Cachard C Phys Med Biol; 2010 Jun; 55(12):3557-75. PubMed ID: 20508319 [TBL] [Abstract][Full Text] [Related]
7. Curvature affects Doppler investigation of vessels: implications for clinical practice. Balbis S; Roatta S; Guiot C Ultrasound Med Biol; 2005 Jan; 31(1):65-77. PubMed ID: 15653232 [TBL] [Abstract][Full Text] [Related]
8. Preservation of quadrature Doppler signals from bidirectional slow blood flow close to the vessel wall using an adaptive decomposition algorithm. Zhang Y; Shi X; Zhang K; Chen J Med Eng Phys; 2009 Mar; 31(2):268-75. PubMed ID: 18829373 [TBL] [Abstract][Full Text] [Related]
9. Correlation between the characteristics of acceleration and visco elasticity of artery wall under pulsatile flow conditions (physical meaning of I* as a parameter of progressive behaviors of atherosclerosis and arteriosclerosis). Yokobori AT; Ohmi T; Monma R; Tomono Y; Inoue K; Owa M; Ichiki M; Mochizuki N; Yamashita H Biomed Mater Eng; 2013; 23(1-2):75-91. PubMed ID: 23442239 [TBL] [Abstract][Full Text] [Related]
10. Effects of nonuniform insonation by catheter-tipped Doppler transducers on velocity estimation. Moraes R; Evans DH Ultrasound Med Biol; 1995; 21(6):779-91. PubMed ID: 8571466 [TBL] [Abstract][Full Text] [Related]
11. Acoustic intensity for a long vessel with noncircular cross section. Thompson RS; Macaskill C; Fraser WB; Farnell L IEEE Trans Ultrason Ferroelectr Freq Control; 2004 May; 51(5):566-75. PubMed ID: 15217234 [TBL] [Abstract][Full Text] [Related]
12. Intravascular elasticity imaging using ultrasound: feasibility studies in phantoms. de Korte CL; Ignacio Céspedes EI; van der Steen AF; Lancée CT Ultrasound Med Biol; 1997; 23(5):735-46. PubMed ID: 9253821 [TBL] [Abstract][Full Text] [Related]
13. Comparative study of viscoelastic arterial wall models in nonlinear one-dimensional finite element simulations of blood flow. Raghu R; Vignon-Clementel IE; Figueroa CA; Taylor CA J Biomech Eng; 2011 Aug; 133(8):081003. PubMed ID: 21950896 [TBL] [Abstract][Full Text] [Related]
14. Hybrid concept on the mechanical test method of small caliber blood vessel. Yokobori AT; Ohkuma T; Yoshinari H; Ichiki M; Ohuchi H; Yokobori T Biomed Mater Eng; 1993; 3(4):175-83. PubMed ID: 8205059 [TBL] [Abstract][Full Text] [Related]
15. Multi-scale finite element analyses for stress and strain evaluations of braid fibril artificial blood vessel and smooth muscle cell. Nakamachi E; Uchida T; Kuramae H; Morita Y Int J Numer Method Biomed Eng; 2014 Aug; 30(8):796-813. PubMed ID: 24599892 [TBL] [Abstract][Full Text] [Related]
16. Adapting the Lagrangian speckle model estimator for endovascular elastography: theory and validation with simulated radio-frequency data. Maurice RL; Ohayon J; Finet G; Cloutier G J Acoust Soc Am; 2004 Aug; 116(2):1276-86. PubMed ID: 15376693 [TBL] [Abstract][Full Text] [Related]
18. Frequency response of blood vessel wall with atherosclerosis and aneurysm. Yokobori AT; Ichiki M; Tomono Y; Tanaka D; Kanno T; Sugiura R; Ohtomo Y; Ito M; Ohgoshi S Biomed Mater Eng; 2011; 21(3):171-7. PubMed ID: 22072081 [TBL] [Abstract][Full Text] [Related]
19. Angiographic methods for the study of fluid mechanical factors in atherogenesis. Smedby O Acta Radiol Suppl; 1992; 380():1-38. PubMed ID: 1414424 [TBL] [Abstract][Full Text] [Related]
20. [Ultrasonic duplex scanner in the examination of blood vessels]. Haapanen A Duodecim; 1990; 106(15):1114-23. PubMed ID: 1670526 [No Abstract] [Full Text] [Related] [Next] [New Search]