These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 7921671)

  • 1. Development of a highly sensitive probe for measuring oxygen in biological tissues.
    Zweier JL; Chzhan M; Ewert U; Schneider G; Kuppusamy P
    J Magn Reson B; 1994 Sep; 105(1):52-7. PubMed ID: 7921671
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of nitric oxide with a solid-state-char EPR probe.
    Zweier JL; Samouilov A; Chzhan M
    J Magn Reson B; 1995 Dec; 109(3):259-63. PubMed ID: 8542194
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of oxygen concentrations in the intact beating heart using electron paramagnetic resonance spectroscopy: a technique for measuring oxygen concentrations in situ.
    Zweier JL; Thompson-Gorman S; Kuppusamy P
    J Bioenerg Biomembr; 1991 Dec; 23(6):855-71. PubMed ID: 1663949
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Direct and Repeated Measurement of Heart and Brain Oxygenation Using In Vivo EPR Oximetry.
    Khan N; Hou H; Swartz HM; Kuppusamy P
    Methods Enzymol; 2015; 564():529-52. PubMed ID: 26477264
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Functional electron paramagnetic resonance imaging of ischemic rat heart: Monitoring of tissue oxygenation and pH.
    Gorodetsky AA; Kirilyuk IA; Khramtsov VV; Komarov DA
    Magn Reson Med; 2016 Jul; 76(1):350-8. PubMed ID: 26301868
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Implantable resonators--a technique for repeated measurement of oxygen at multiple deep sites with in vivo EPR.
    Li H; Hou H; Sucheta A; Williams BB; Lariviere JP; Khan MN; Lesniewski PN; Gallez B; Swartz HM
    Adv Exp Med Biol; 2010; 662():265-72. PubMed ID: 20204802
    [TBL] [Abstract][Full Text] [Related]  

  • 7. EPR oximetry in the beating heart: myocardial oxygen consumption rate as an index of postischemic recovery.
    Ilangovan G; Liebgott T; Kutala VK; Petryakov S; Zweier JL; Kuppusamy P
    Magn Reson Med; 2004 Apr; 51(4):835-42. PubMed ID: 15065258
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Carbon-centered radicals as oxygen sensors for in vivo electron paramagnetic resonance: screening for an optimal probe among commercially available charcoals.
    Jordan BF; Baudelet C; Gallez B
    MAGMA; 1998 Dec; 7(2):121-9. PubMed ID: 9951772
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A highly sensitive biocompatible spin probe for imaging of oxygen concentration in tissues.
    Bratasz A; Kulkarni AC; Kuppusamy P
    Biophys J; 2007 Apr; 92(8):2918-25. PubMed ID: 17259268
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo electron paramagnetic resonance oximetry with particulate materials.
    Dunn JF; Swartz HM
    Methods; 2003 Jun; 30(2):159-66. PubMed ID: 12725782
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electron paramagnetic resonance monitoring of ischemia-induced myocardial oxygen depletion and acidosis in isolated rat hearts using soluble paramagnetic probes.
    Komarov DA; Dhimitruka I; Kirilyuk IA; Trofimiov DG; Grigor'ev IA; Zweier JL; Khramtsov VV
    Magn Reson Med; 2012 Aug; 68(2):649-55. PubMed ID: 22162021
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of magnetic field over-modulation for improved EPR linewidth measurements using probes with Lorentzian lineshape.
    Deng Y; Pandian RP; Ahmad R; Kuppusamy P; Zweier JL
    J Magn Reson; 2006 Aug; 181(2):254-61. PubMed ID: 16759891
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electron paramagnetic resonance imaging of the rat heart.
    Zweier JL; Chzhan M; Samouilov A; Kuppusamy P
    Phys Med Biol; 1998 Jul; 43(7):1823-35. PubMed ID: 9703044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of biocompatible oxygen-permeable films holding paramagnetic carbon particles: evaluation of their performance and stability in EPR oximetry.
    He J; Beghein N; Ceroke P; Clarkson RB; Swartz HM; Gallez B
    Magn Reson Med; 2001 Sep; 46(3):610-4. PubMed ID: 11550256
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measuring Flap Oxygen Using Electron Paramagnetic Resonance Oximetry.
    Polacco MA; Hou H; Kuppusamy P; Chen EY
    Laryngoscope; 2019 Dec; 129(12):E415-E419. PubMed ID: 31034638
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microencapsulation of paramagnetic particles by pyrroxylin to preserve their responsiveness to oxygen when used as sensors for in vivo EPR oximetry.
    Gallez B; Jordan BF; Baudelet C
    Magn Reson Med; 1999 Jul; 42(1):193-6. PubMed ID: 10398966
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electron paramagnetic resonance and dynamic nuclear polarization of char suspensions: surface science and oximetry.
    Clarkson RB; Odintsov BM; Ceroke PJ; Ardenkjaer-Larsen JH; Fruianu M; Belford RL
    Phys Med Biol; 1998 Jul; 43(7):1907-20. PubMed ID: 9703054
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanism of oxygen-induced EPR line broadening in lithium phthalocyanine microcrystals.
    Ilangovan G; Zweier JL; Kuppusamy P
    J Magn Reson; 2004 Sep; 170(1):42-8. PubMed ID: 15324756
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High spatial resolution multisite EPR oximetry of transient focal cerebral ischemia in the rat.
    Williams BB; Hou H; Grinberg OY; Demidenko E; Swartz HM
    Antioxid Redox Signal; 2007 Oct; 9(10):1691-8. PubMed ID: 17678442
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A naphthalocyanine-based EPR probe for localized measurements of tissue oxygenation.
    Ilangovan G; Manivannan A; Li H; Yanagi H; Zweier JL; Kuppusamy P
    Free Radic Biol Med; 2002 Jan; 32(2):139-47. PubMed ID: 11796202
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.