These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 7930538)

  • 1. Persistence of microflora in biofilm within fluid pathways of contemporary haemodialysis monitors (Gambro AK-10).
    Phillips G; Hudson S; Stewart WK
    J Hosp Infect; 1994 Jun; 27(2):117-25. PubMed ID: 7930538
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Effects of different procedures of disinfection on the bacteriologic quality of hemodialysis monitors of the Cobe CS3 and AK 100 type].
    Di Majo P; Hartemann P; Andre JL
    Zentralbl Hyg Umweltmed; 1996 Mar; 198(4):340-54. PubMed ID: 9376059
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Defining the microbiological quality of dialysis fluid.
    Ledebo I; Nystrand R
    Artif Organs; 1999 Jan; 23(1):37-43. PubMed ID: 9950177
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evidence of bacterial biofilm in tubing from hydraulic pathway of hemodialysis system.
    Man NK; Degremont A; Darbord JC; Collet M; Vaillant P
    Artif Organs; 1998 Jul; 22(7):596-600. PubMed ID: 9684698
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Bacterial biofilms on PVC tubing's inner surface of hemodialysis water treatment system].
    Yang S; Jia K; Peng Y; Liu H; Liu Y; Chen X; Liu F
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2009 Oct; 34(10):1029-35. PubMed ID: 19893257
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of biofilm formation on haemodialysis monitor disinfection.
    Cappelli G; Sereni L; Scialoja MG; Morselli M; Perrone S; Ciuffreda A; Bellesia M; Inguaggiato P; Albertazzi A; Tetta C
    Nephrol Dial Transplant; 2003 Oct; 18(10):2105-11. PubMed ID: 13679487
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dental unit waterlines: biofilms, disinfection and recurrence.
    Meiller TF; Depaola LG; Kelley JI; Baqui AA; Turng BF; Falkler WA
    J Am Dent Assoc; 1999 Jan; 130(1):65-72. PubMed ID: 9919033
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Identification of the bacteriologicalcontamination of a water treatment line used for haemodialysis and its disinfection.
    Morin P
    J Hosp Infect; 2000 Jul; 45(3):218-24. PubMed ID: 10896801
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experience in using thermal disinfection to remove viable bacteria and endotoxins in centraly distributed reverse osmosis water.
    Alayoud A; Hamzi MA; Razkaoui A; Benyahia M
    Arab J Nephrol Transplant; 2014 Jan; 7(1):27-31. PubMed ID: 24702531
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Profiling Total Viable Bacteria in a Hemodialysis Water Treatment System.
    Chen L; Zhu X; Zhang M; Wang Y; Lv T; Zhang S; Yu X
    J Microbiol Biotechnol; 2017 May; 27(5):995-1004. PubMed ID: 28285498
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microbial growth and blockage of sub-floor drains in a renal dialysis centre: a problem highlighted.
    Phillips G; Hudson S; Stewart WK
    J Hosp Infect; 1992 Jul; 21(3):193-8. PubMed ID: 1353511
    [TBL] [Abstract][Full Text] [Related]  

  • 12. When good water goes bad: how it happens, clinical consequences and possible solutions.
    Lonnemann G
    Blood Purif; 2004; 22(1):124-9. PubMed ID: 14732820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Endotoxin and bacterial contamination of dialysis center water and dialysate; a cross sectional survey.
    Harding GB; Klein E; Pass T; Wright R; Million C
    Int J Artif Organs; 1990 Jan; 13(1):39-43. PubMed ID: 2394493
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microbiological quality of water and dialysate in a haemodialysis unit in Ponta Grossa-PR, Brazil.
    Borges CR; Lascowski KM; Filho NR; Pelayo JS
    J Appl Microbiol; 2007 Nov; 103(5):1791-7. PubMed ID: 17953589
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dialysis fluid contamination of pathways and life of microbes.
    Nystrand R
    EDTNA ERCA J; 2001; 27(3):135-9. PubMed ID: 11868995
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-permeable membranes and hypersensitivity-like reactions: role of dialysis fluid contamination.
    Bigazzi R; Atti M; Baldari G
    Blood Purif; 1990; 8(4):190-8. PubMed ID: 2085427
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrafiltration of dialysis fluid to obtain a sterile solution during hemodialysis.
    Bambauer R; Walther J; Jung WK
    Blood Purif; 1990; 8(6):309-17. PubMed ID: 2093329
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Occurrence of endotoxin in dialysis fluid from 39 dialysis units.
    Kulander L; Nisbeth U; Danielsson BG; Eriksson O
    J Hosp Infect; 1993 May; 24(1):29-37. PubMed ID: 8101200
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effectiveness of various chemical disinfectants versus cleaning combined with heat disinfection on Pseudomonas biofilm in hemodialysis machines.
    Holmes CJ; Degremont A; Kubey W; Straka P; Man NK
    Blood Purif; 2004; 22(5):461-8. PubMed ID: 15359105
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Purification of dialysis fluid: historical background and perspective.
    Ledebo I
    Blood Purif; 2009; 27 Suppl 1():17-9. PubMed ID: 19556758
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.