These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 7935206)

  • 1. Implementation of a modified birdcage resonator for 19F/1H MRI at low fields (0.14 T).
    Samaratunga RC; Pratt RG; Zhu Y; Massoth RJ; Thomas SR
    Med Phys; 1994 May; 21(5):697-705. PubMed ID: 7935206
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and evaluation of a radio frequency coil for nuclear magnetic resonance imaging of fluorine and protons.
    Joseph PM; Fishman JE
    Med Phys; 1985; 12(6):679-83. PubMed ID: 4079857
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A technique of double-resonant operation of 19F and 1H quadrature birdcage coils.
    Lu DF; Joseph PM
    Magn Reson Med; 1991 May; 19(1):180-5. PubMed ID: 2046532
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A dual
    Villa-Valverde P; Rodríguez I; Padró D; Benito M; Garrido-Salmon CE; Ruiz-Cabello J
    MAGMA; 2019 Feb; 32(1):79-87. PubMed ID: 30778714
    [TBL] [Abstract][Full Text] [Related]  

  • 5. B1 field homogeneity and SAR calculations for the birdcage coil.
    Ibrahim TS; Lee R; Baertlein BA; Robitaille PM
    Phys Med Biol; 2001 Feb; 46(2):609-19. PubMed ID: 11229737
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A fast and accurate simulator for the design of birdcage coils in MRI.
    Giovannetti G; Landini L; Santarelli MF; Positano V
    MAGMA; 2002 Nov; 15(1-3):36-44. PubMed ID: 12413563
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Double-tuned radiofrequency coil for (19)F and (1)H imaging.
    Otake Y; Soutome Y; Hirata K; Ochi H; Bito Y
    Magn Reson Med Sci; 2014; 13(3):199-205. PubMed ID: 24990464
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An Asymmetric Birdcage Coil for Small-animal MR Imaging at 7T.
    Kim KN; Han SD; Seo JH; Heo P; Yoo D; Im GH; Lee JH
    Magn Reson Med Sci; 2017 Jul; 16(3):253-258. PubMed ID: 27725573
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dual resonant birdcage coils for 1H detected 13C microscopic imaging at 11.7 T.
    Hudson AM; Köckenberger W; Bowtell RW
    MAGMA; 2000 Jun; 10(2):61-8. PubMed ID: 10873194
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A new approach to research graphical performance of MRI RF coil based on the quantitative comparison method].
    Zhu G; Li B; Wei X
    Zhongguo Yi Liao Qi Xie Za Zhi; 2010 May; 34(3):180-2. PubMed ID: 20812640
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the RF field uniformity of a double-tuned 31P/1H birdcage RF coil for spin-echo MRI/MRS of the diabetic foot.
    Greenman RL; Rakow-Penner R
    J Magn Reson Imaging; 2005 Sep; 22(3):427-32. PubMed ID: 16104007
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An efficient birdcage resonator at 2.5 MHz using a novel multilayer self-capacitance construction technique.
    Yeung D; Hutchison JM; Lurie DJ
    MAGMA; 1995; 3(3-4):163-8. PubMed ID: 8749735
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison and evaluation of mouse cardiac MRI acquired with open birdcage, single loop surface and volume birdcage coils.
    Fan X; Markiewicz EJ; Zamora M; Karczmar GS; Roman BB
    Phys Med Biol; 2006 Dec; 51(24):N451-9. PubMed ID: 17148815
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A birdcage coil tuned by RF shielding for application at 9.4 T.
    Dardzinski BJ; Li S; Collins CM; Williams GD; Smith MB
    J Magn Reson; 1998 Mar; 131(1):32-8. PubMed ID: 9533903
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Open access birdcage coils for microscopic imaging of plants at 11.7 T.
    Hudson AM; Köckenberger W; Bowtell RW
    MAGMA; 2000 Jun; 10(2):69-74. PubMed ID: 10873195
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A PIN diode controlled dual-tuned MRI RF coil and phased array for multi nuclear imaging.
    Ha S; Hamamura MJ; Nalcioglu O; Muftuler LT
    Phys Med Biol; 2010 May; 55(9):2589-600. PubMed ID: 20393229
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Low-frequency quadrature mode birdcage resonator.
    Borsboom HM; Claasen-Vujcić T; Gaykema HJ; Mehlkopf T
    MAGMA; 1997 Mar; 5(1):33-7. PubMed ID: 9219177
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A generalized strategy for designing (19)F/(1)H dual-frequency MRI coil for small animal imaging at 4.7 Tesla.
    Hu L; Hockett FD; Chen J; Zhang L; Caruthers SD; Lanza GM; Wickline SA
    J Magn Reson Imaging; 2011 Jul; 34(1):245-52. PubMed ID: 21698714
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transmission line analysis of noncylindrical birdcage resonators.
    Vullo T; Pascone R; Mancuso R; Zipagan R; Cahill PT
    Magn Reson Imaging; 1994; 12(5):785-97. PubMed ID: 7934665
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Numerical and Workbench Design of 2.35 T Double-Tuned (¹H/²³Na) Nested RF Birdcage Coils Suitable for Animal Size MRI.
    Fantasia M; Galante A; Maggiorelli F; Retico A; Fontana N; Monorchio A; Alecci M
    IEEE Trans Med Imaging; 2020 Oct; 39(10):3175-3186. PubMed ID: 32310762
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.