These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Clinical comparison of ocular blood flow tonometer, Tonopen, and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes. Rao VJ; Gnanaraj L; Mitchell KW; Figueiredo FC Cornea; 2001 Nov; 20(8):834-8. PubMed ID: 11685061 [TBL] [Abstract][Full Text] [Related]
3. Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer. Gunvant P; Baskaran M; Vijaya L; Joseph IS; Watkins RJ; Nallapothula M; Broadway DC; O'Leary DJ Br J Ophthalmol; 2004 Apr; 88(4):518-22. PubMed ID: 15031169 [TBL] [Abstract][Full Text] [Related]
4. [How does central cornea thickness influence intraocular pressure during applanation and contour tonometry?]. Schwenteck T; Knappe M; Moros I Klin Monbl Augenheilkd; 2012 Sep; 229(9):917-27. PubMed ID: 22972357 [TBL] [Abstract][Full Text] [Related]
5. The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat. Kontiola AI; Goldblum D; Mittag T; Danias J Exp Eye Res; 2001 Dec; 73(6):781-5. PubMed ID: 11846509 [TBL] [Abstract][Full Text] [Related]
6. Reproducibility of measurements with a new slit lamp-mounted ocular blood flow tonograph. Spraul CW; Lang GE; Ronzani M; Högel J; Lang GK Graefes Arch Clin Exp Ophthalmol; 1998 Apr; 236(4):274-9. PubMed ID: 9561360 [TBL] [Abstract][Full Text] [Related]
7. [Reliability and reproducibility of introcular pressure (IOP) measurement with the Icare Valero B; Fénolland JR; Rosenberg R; Sendon D; Mesnard C; Sigaux M; Giraud JM; Renard JP J Fr Ophtalmol; 2017 Dec; 40(10):865-875. PubMed ID: 29174296 [TBL] [Abstract][Full Text] [Related]
8. Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer. Saleh TA; Adams M; McDermott B; Claridge KG; Ewings P Clin Exp Ophthalmol; 2006 Aug; 34(6):516-20. PubMed ID: 16925697 [TBL] [Abstract][Full Text] [Related]
9. Comparison of the transpalpebral tonometer TGDc-01 with Goldmann applanation tonometry. Waisbourd M; Shemesh G; Top LB; Lazar M; Loewenstein A Eur J Ophthalmol; 2010; 20(5):902-6. PubMed ID: 20306444 [TBL] [Abstract][Full Text] [Related]
10. Non-invasive determination of intraocular pressure in the rat eye. Comparison of an electronic tonometer (TonoPen), and a rebound (impact probe) tonometer. Goldblum D; Kontiola AI; Mittag T; Chen B; Danias J Graefes Arch Clin Exp Ophthalmol; 2002 Nov; 240(11):942-6. PubMed ID: 12486518 [TBL] [Abstract][Full Text] [Related]
11. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Bhan A; Browning AC; Shah S; Hamilton R; Dave D; Dua HS Invest Ophthalmol Vis Sci; 2002 May; 43(5):1389-92. PubMed ID: 11980851 [TBL] [Abstract][Full Text] [Related]
12. [Tonometry in change. From indentation and applanation to contour adaptation]. Kanngiesser H; Kniestedt C Ophthalmologe; 2005 Sep; 102(9):849-55. PubMed ID: 16132995 [TBL] [Abstract][Full Text] [Related]
13. [A comparison study of pulsitile ocular blood flow in normal eyes and primary open angle glaucoma]. Zhang MZ; Fu ZF; Liu XR; Zheng C Zhonghua Yan Ke Za Zhi; 2004 Apr; 40(4):250-3. PubMed ID: 15268833 [TBL] [Abstract][Full Text] [Related]
14. Ocular blood flow tonometer reproducibility: the effect of operator experience and mode of application. Morgan A; Hosking S Ophthalmic Physiol Opt; 2001 Sep; 21(5):401-6. PubMed ID: 11563428 [TBL] [Abstract][Full Text] [Related]
15. Tono-Pen tonometer and corneal thickness. Mok KH; Wong CS; Lee VW Eye (Lond); 1999; 13 ( Pt 1)():35-7. PubMed ID: 10396381 [TBL] [Abstract][Full Text] [Related]
16. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology. von Spiessen L; Karck J; Rohn K; Meyer-Lindenberg A Vet Ophthalmol; 2015 Jan; 18(1):20-7. PubMed ID: 24131625 [TBL] [Abstract][Full Text] [Related]
17. [Contemporary possibilities of intraocular pressure measurement]. Hornová J; Baxant A Cesk Slov Oftalmol; 2013 Oct; 69(4):175-80. PubMed ID: 24437996 [TBL] [Abstract][Full Text] [Related]
18. Intraocular pressure and pulse rate measurements by the OBF tonograph--comparison to reference instruments. Yang YC; Illango B; Cook A; Batterbury M Ophthalmic Physiol Opt; 2000 Sep; 20(5):401-7. PubMed ID: 11045249 [TBL] [Abstract][Full Text] [Related]
19. Corneal biomechanical properties: precision and influence on tonometry. Ogbuehi KC; Osuagwu UL Cont Lens Anterior Eye; 2014 Jun; 37(3):124-31. PubMed ID: 24121009 [TBL] [Abstract][Full Text] [Related]
20. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Tonnu PA; Ho T; Newson T; El Sheikh A; Sharma K; White E; Bunce C; Garway-Heath D Br J Ophthalmol; 2005 Jul; 89(7):851-4. PubMed ID: 15965165 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]