These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 7940150)

  • 21. A preliminary study on the ocular blood flow (OBF) of Hong Kong Chinese.
    Lam AK; Chan H; Fan W; To CH
    Ophthalmic Physiol Opt; 1999 Nov; 19(6):512-7. PubMed ID: 10768035
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Measurement of intraocular pressure (IOP) in chickens using a rebound tonometer: quantitative evaluation of variance due to position inaccuracies.
    Prashar A; Guggenheim JA; Erichsen JT; Hocking PM; Morgan JE
    Exp Eye Res; 2007 Oct; 85(4):563-71. PubMed ID: 17719031
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Optical measurement of the corneal oscillation for the determination of the intraocular pressure.
    Osmers J; Sorg M; Fischer A
    Biomed Tech (Berl); 2019 Aug; 64(4):471-480. PubMed ID: 30231007
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Method for the noninvasive measurement of intraocular pressure in mice.
    Danias J; Kontiola AI; Filippopoulos T; Mittag T
    Invest Ophthalmol Vis Sci; 2003 Mar; 44(3):1138-41. PubMed ID: 12601041
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Intra-eye pressure range and pulse profiles in normals with the Pulsair non-contact tonometer.
    Vernon SA
    Eye (Lond); 1993; 7 ( Pt 1)():134-7. PubMed ID: 8325403
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Rebound tonometry in conscious, conditioned mice avoids the acute and profound effects of anesthesia on intraocular pressure.
    Johnson TV; Fan S; Toris CB
    J Ocul Pharmacol Ther; 2008 Apr; 24(2):175-85. PubMed ID: 18355131
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of intraocular pressure estimates obtained using an iCare rebound tonometer.
    Khanal S; Walton M; Davey PG
    Clin Exp Optom; 2017 Mar; 100(2):179-183. PubMed ID: 27701775
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Effects of central corneal thickness and corneal curvature on measurement of intraocular pressure with Goldmann applanation tonometer and non-contact tonometer].
    Zhang Y; Zhao JL; Bian AL; Liu XL; Jin YM
    Zhonghua Yan Ke Za Zhi; 2009 Aug; 45(8):713-8. PubMed ID: 20021884
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Goldmann applanation tonometer versus ocular response analyzer for measuring intraocular pressure after congenital cataract surgery.
    Feizi S; Faramarzi A; Kheiri B
    Eur J Ophthalmol; 2018 Sep; 28(5):582-589. PubMed ID: 30246567
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer over a wide IOP range.
    Munkwitz S; Elkarmouty A; Hoffmann EM; Pfeiffer N; Thieme H
    Graefes Arch Clin Exp Ophthalmol; 2008 Jun; 246(6):875-9. PubMed ID: 18196259
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Dynamic contour tonometry: presentation of a new tonometer.
    Kanngiesser HE; Kniestedt C; Robert YC
    J Glaucoma; 2005 Oct; 14(5):344-50. PubMed ID: 16148581
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The ocular blood flow tonograph: a new instrument for the measurement of intraocular pressure in rabbits.
    Chidlow G; Nash MS; Crowhurst C; Bron AJ; Osborne NN
    Exp Eye Res; 1996 Oct; 63(4):463-9. PubMed ID: 8944553
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of intraocular pressure measurements obtained by use of a rebound tonometer and applanation tonometer in dogs before and after elective phacoemulsification.
    Thompson-Hom AL; Gerding PA
    Am J Vet Res; 2012 May; 73(5):709-13. PubMed ID: 22533404
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of the intraocular pressure measured with the ocular response analyzer.
    Ogbuehi KC; Almubrad TM
    Curr Eye Res; 2010 Jul; 35(7):587-96. PubMed ID: 20597645
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A resonator sensor for measurement of intraocular pressure--evaluation in an in vitro pig-eye model.
    Eklund A; Bäcklund T; Lindahl OA
    Physiol Meas; 2000 Aug; 21(3):355-67. PubMed ID: 10984204
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions.
    Lee TE; Yoo C; Hwang JY; Lin S; Kim YY
    Curr Eye Res; 2015 Sep; 40(9):923-9. PubMed ID: 25271991
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Measurement of the intraocular pressure with the "transpalpebral tonometer" TGDc-01 in comparison with applanation tonometry.
    Sandner D; Böhm A; Kostov S; Pillunat L
    Graefes Arch Clin Exp Ophthalmol; 2005 Jun; 243(6):563-9. PubMed ID: 15614540
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Clinical evaluation of the ICare tonometer in measuring intraocular pressure].
    Krzyzanowska-Berkowska P; Asejczyk-Widlicka M
    Klin Oczna; 2010; 112(7-9):217-20. PubMed ID: 21121124
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [New measuring method of non-contact tonometry].
    Plagwitz KU; Lemke K
    Klin Monbl Augenheilkd; 1999 Jan; 214(1):40-3. PubMed ID: 10198881
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice.
    Alvarez TL; Gollance SA; Thomas GA; Greene RJ; Marchetto PM; Moore EJ; Realini T; Liebmann JM; Ritch R; Lama P; Fechtner RD
    Ophthalmology; 2004 Jun; 111(6):1077-85. PubMed ID: 15177956
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.