  • 1. Volume spirometers need automated internal temperature sensors.
    Johnson LR; Enright PL; Voelker HT; Tashkin DP
    Am J Respir Crit Care Med; 1994 Dec; 150(6 Pt 1):1575-80. PubMed ID: 7952617
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Temperature corrections in routine spirometry.
    Cramer D; Peacock A; Denison D
    Thorax; 1984 Oct; 39(10):771-4. PubMed ID: 6495245
    [TBL] [Abstract][Full Text] [Related]  

  • 3. BTPS correction with dynamic spirometers.
    Forche G; Harnoncourt K; Stadlober E; Zenker G
    Respiration; 1986; 49(4):274-9. PubMed ID: 3715213
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of temperature on Vitalograph spirometer readings.
    Perks WH; Sopwith T; Brown D; Jones CH; Green M
    Thorax; 1983 Aug; 38(8):592-4. PubMed ID: 6612650
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of spirometer temperature on FEV1 in a longitudinal epidemiological study.
    Gilliland FD; Linn W; Rappaport E; Avol E; Gong H; Peters J
    Occup Environ Med; 1999 Oct; 56(10):718-20. PubMed ID: 10658554
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Temperature standardization of multiple spirometers.
    Linn WS; Solomon JC; Gong H; Avol EL; Peters JM
    J Occup Environ Med; 1998 Feb; 40(2):148-52. PubMed ID: 9503291
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Agreement between spirometers: a challenge in the follow-up of patients and populations?
    Gerbase MW; Dupuis-Lozeron E; Schindler C; Keidel D; Bridevaux PO; Kriemler S; Probst-Hensch NM; Rochat T; Künzli N
    Respiration; 2013; 85(6):505-14. PubMed ID: 23485575
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Evaluation of the reliability of 2 portable electronic spirometers].
    Tschopp JM; Roulin JP; Juilland A; Erné R
    Schweiz Med Wochenschr; 1988 Sep; 118(38):1382-5. PubMed ID: 3187474
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy and repeatability of a pocket turbine spirometer: comparison with a rolling seal flow-volume spirometer.
    Malmberg LP; Hedman J; Sovijärvi AR
    Clin Physiol; 1993 Jan; 13(1):89-98. PubMed ID: 8435980
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical comparison of two electronic spirometers with a water-sealed spirometer.
    Shanks DE; Morris JF
    Chest; 1976 Apr; 69(4):461-6. PubMed ID: 1261311
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dynamic BTPS correction factors for spirometric data.
    Hankinson JL; Viola JO
    J Appl Physiol Respir Environ Exerc Physiol; 1983 Oct; 55(4):1354-60. PubMed ID: 6629969
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A simple office spirometer for the pediatrician.
    Goddard RF; Klein WM; Smith RM
    Ann Allergy; 1980 Apr; 44(4):206-11. PubMed ID: 7369554
    [TBL] [Abstract][Full Text] [Related]  

  • 13. BTPS correction for ceramic flow sensor.
    Hankinson JL; Viola JO; Petsonk EL; Ebeling TR
    Chest; 1994 May; 105(5):1481-6. PubMed ID: 8181341
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of spirometer temperature on measurement of FEV1 shift changes.
    Hankinson JL; Castellan RM; Kinsley KB; Keimig DG
    J Occup Med; 1986 Dec; 28(12):1222-5. PubMed ID: 3806261
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the Cavitron Spirometric Computer for accuracy in clinical screening spirometry.
    Cissik JH; Cramer TJ; Shelman LL
    Aviat Space Environ Med; 1981 Feb; 52(2):125-9. PubMed ID: 7213297
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical evaluation of five spirometers. Monaghan M403, Pneumoscreen, Spirotron, Vicatest and Vitalograph.
    Wever AM; Britton MG; Hughes DT; Van der Plas KH; Wever-Hess J
    Eur J Respir Dis; 1981; 62(2):127-37. PubMed ID: 7238663
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Spirometry in primary care in Navarre, Spain].
    Hueto J; Cebollero P; Pascal I; Cascante JA; Eguía VM; Teruel F; Carpintero M
    Arch Bronconeumol; 2006 Jul; 42(7):326-31. PubMed ID: 16945262
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluating commercially available spirometers.
    Gardner RM; Hankinson JL; West BJ
    Am Rev Respir Dis; 1980 Jan; 121(1):73-82. PubMed ID: 7352715
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spirometer Replacement and Serial Lung Function Measurements in Population Studies: Results From the SAPALDIA Study.
    Bridevaux PO; Dupuis-Lozeron E; Schindler C; Keidel D; Gerbase MW; Probst-Hensch NM; Bettschart R; Burdet L; Pons M; Rothe T; Turk A; Stolz D; Tschopp JM; Kuenzli N; Rochat T
    Am J Epidemiol; 2015 May; 181(10):752-61. PubMed ID: 25816817
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Standardization of different spirometers.
    Ali BA; Abro YM; Javed NH; Islam MS
    Respiration; 1988; 53(1):58-63. PubMed ID: 3387691