BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 7952672)

  • 1. Haematological variations in pigs during experimental left ventricular assistance with a pulsatile impeller pump.
    Qian KX; Wang SS; Chu SH
    Med Eng Phys; 1994 Jul; 16(4):348-50. PubMed ID: 7952672
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative testing of pulsatile impeller total heart and sarns nonpulsatile roller as biventricular assist device in pigs.
    Qian KX; Wang SS; Chu SH
    Med Eng Phys; 1996 Jun; 18(4):320-5. PubMed ID: 8782191
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo studies of pulsatile implantable impeller assist and total hearts.
    Qian KX; Wang SS; Chu SH
    Artif Organs; 1995 Apr; 19(4):328-33. PubMed ID: 7598652
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Haematological variations of experimental pigs during biventricular assistance with impeller total heart.
    Qian KX; Wang SS; Chu SH
    Med Eng Phys; 1996 Jan; 18(1):67-9. PubMed ID: 8771041
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulsatile impeller heart: a viable alternative to a problematic diaphragm heart.
    Qian KX
    Med Eng Phys; 1996 Jan; 18(1):57-66. PubMed ID: 8771040
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The realization of a pulsatile implantable impeller pump with low hemolysis.
    Qian KX; Fei Q; Lin KD; Pi KD; Wang YP
    Artif Organs; 1989 Apr; 13(2):162-9. PubMed ID: 2705888
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulsatile blood flow from impeller pump: a dream has come true.
    Qian KX
    J Biomater Appl; 1994 Oct; 9(2):158-77. PubMed ID: 7782998
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of an impeller centrifugal pump on blood components in chronic animal experiments.
    Taenaka Y; Inoue K; Masuzawa T; Araki K; Sakaki M; Matsuo Y; Akagi H; Nakatani T; Kinoshita M; Baba Y
    ASAIO J; 1992; 38(3):M577-9. PubMed ID: 1457925
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of left ventricular assist device performance and hydraulic force in a complete mock circulation loop.
    Timms D; Hayne M; Tan A; Pearcy M
    Artif Organs; 2005 Jul; 29(7):573-80. PubMed ID: 15982286
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Haemolysis test of non-pulsatile and pulsatile impeller blood pumps.
    Qian KX; Fei Q
    Clin Phys Physiol Meas; 1988 May; 9(2):107-12. PubMed ID: 3391012
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo evaluation of a pulsatile impeller total heart.
    Qian KX; Wang SS; Chu SH
    ASAIO J; 1994; 40(2):213-5. PubMed ID: 8003761
    [TBL] [Abstract][Full Text] [Related]  

  • 12. How to produce a pulsatile flow with low haemolysis?
    Qian KX; Zeng P; Ru WM; Yuan HY; Feng ZG; Li I
    J Med Eng Technol; 2000; 24(5):227-9. PubMed ID: 11204246
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Renal circulation and cellular metabolism during left ventricular assisted circulation: comparison study of pulsatile and nonpulsatile assists.
    Sezai A; Shiono M; Orime Y; Nakata K; Hata M; Yamada H; Iida M; Kashiwazaki S; Kinishita J; Nemoto M; Koujima T; Sezai Y; Saitoh T
    Artif Organs; 1997 Jul; 21(7):830-5. PubMed ID: 9212968
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Low haemolysis pulsatile impeller pump: design concepts and experimental results.
    Qian KX
    J Biomed Eng; 1989 Nov; 11(6):478-81. PubMed ID: 2811347
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo testing of a pulsatile implantable impeller pump as a left ventricular assist device used in calves.
    Qian KX; Wang SS; Chu SH
    Perfusion; 1995 Jul; 10(4):257-63. PubMed ID: 7488772
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The hemolysis test of the Gyro C1E3 pump in pulsatile mode.
    Tayama E; Nakazawa T; Takami Y; Makinouchi K; Ohtsubo S; Ohashi Y; Andrade AJ; Glueck J; Mueller J; Nosé Y
    Artif Organs; 1997 Jul; 21(7):675-9. PubMed ID: 9304391
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Toward a durable impeller pump with mechanical bearings.
    Qian KX; Zeng P; Ru WM; Yuan HY; Feng ZG; Li L
    ASAIO J; 2002; 48(3):290-2. PubMed ID: 12059003
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Haemodynamic approach to reducing thrombosis and haemolysis in an impeller pump.
    Qian KX
    J Biomed Eng; 1990 Nov; 12(6):533-5. PubMed ID: 2266752
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device.
    Kitao T; Ando Y; Yoshikawa M; Kobayashi M; Kimura T; Ohsawa H; Machida S; Yokoyama N; Sakota D; Konno T; Ishihara K; Takatani S
    Artif Organs; 2011 May; 35(5):543-53. PubMed ID: 21595723
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical evaluation of pulsatile flow mode of Terumo Capiox centrifugal pump.
    Nishida H; Uesugi H; Nishinaka T; Uwabe K; Aomi S; Endo M; Koyanagi H; Oshiyama H; Nogawa A; Akutsu T
    Artif Organs; 1997 Jul; 21(7):816-21. PubMed ID: 9212965
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.