133 related articles for article (PubMed ID: 7957457)
1. Membrane versus bubble oxygenator in hyperthermic regional perfusion: a prospective randomized clinical study.
Huber R; Mennicke C; Heitmann KU; Helling HJ; Huber PM
Eur Surg Res; 1994; 26(4):210-20. PubMed ID: 7957457
[TBL] [Abstract][Full Text] [Related]
2. Comparison of bubble and membrane oxygenators in short and long perfusions.
Clark RE; Beauchamp RA; Magrath RA; Brooks JD; Ferguson TB; Weldon CS
J Thorac Cardiovasc Surg; 1979 Nov; 78(5):655-66. PubMed ID: 491720
[TBL] [Abstract][Full Text] [Related]
3. Deleterious effects of cardiopulmonary bypass. A prospective study of bubble versus membrane oxygenation.
van Oeveren W; Kazatchkine MD; Descamps-Latscha B; Maillet F; Fischer E; Carpentier A; Wildevuur CR
J Thorac Cardiovasc Surg; 1985 Jun; 89(6):888-99. PubMed ID: 3158783
[TBL] [Abstract][Full Text] [Related]
4. Hyperthermic regional perfusion using membrane- instead of bubble-oxygenators. An experimental and clinical study.
van Os J; Schraffordt Koops H; Oldhoff J; Wildevuur CR
J Cardiovasc Surg (Torino); 1989; 30(4):523-32. PubMed ID: 2777859
[TBL] [Abstract][Full Text] [Related]
5. Oxygen-transfer performance of a newly designed, very low-volume membrane oxygenator.
Burn F; Ciocan S; Carmona NM; Berner M; Sourdon J; Carrel TP; Tevaearai Stahel HT; Longnus SL
Interact Cardiovasc Thorac Surg; 2015 Sep; 21(3):352-8. PubMed ID: 26037378
[TBL] [Abstract][Full Text] [Related]
6. Experimental evaluation of the Medtronic Maxima Forté hollow fiber membrane oxygenator.
Mueller XM; Tevaearai HT; Augstburger M; Horisberger J; von Segesser LK
J Extra Corpor Technol; 1998 Sep; 30(3):115-9. PubMed ID: 10339286
[TBL] [Abstract][Full Text] [Related]
7. Development of the oxygenator: past, present, and future.
Iwahashi H; Yuri K; Nosé Y
J Artif Organs; 2004; 7(3):111-20. PubMed ID: 15558331
[TBL] [Abstract][Full Text] [Related]
8. From the spinning disc to the membrane oxygenator for open-heart surgery.
Björk VO; Sternlieb JJ; Davenport C
Scand J Thorac Cardiovasc Surg; 1985; 19(3):207-16. PubMed ID: 3936170
[TBL] [Abstract][Full Text] [Related]
9. Clinical study of blood trauma during perfusion with membrane and bubble oxygenators.
van den Dungen JJ; Karliczek GF; Brenken U; Homan van der Heide JN; Wildevuur CR
J Thorac Cardiovasc Surg; 1982 Jan; 83(1):108-16. PubMed ID: 7054605
[TBL] [Abstract][Full Text] [Related]
10. Pulsatile and nonpulsatile extracorporeal circulation using Capiox E terumo oxygenator: a comparison study with Ultrox and Maxima membrane oxygenators.
Minami K; Bairaktaris A; Murray E; Weitkemper H; Dramburg W; Körfer R
J Cardiovasc Surg (Torino); 1997 Jun; 38(3):227-32. PubMed ID: 9219471
[TBL] [Abstract][Full Text] [Related]
11. The new advanced membrane gas exchanger.
Berdajs DA; de Stefano E; Delay D; Ferrari E; Horisberger J; Ditmar Q; von Segesser LK
Interact Cardiovasc Thorac Surg; 2011 Dec; 13(6):591-6. PubMed ID: 21835847
[TBL] [Abstract][Full Text] [Related]
12. Membrane versus bubble oxygenator for cardiac operations. A prospective randomized study.
Hessel EA; Johnson DD; Ivey TD; Miller DW
J Thorac Cardiovasc Surg; 1980 Jul; 80(1):111-22. PubMed ID: 6966720
[TBL] [Abstract][Full Text] [Related]
13. Controlled cardiotomy suction during clinical bubble oxygenator perfusions.
Boonstra PW; Vermeulen FE; Leusink JA; de Nooy EH; van Zalk A; Soons JB; Wildevuur CR
Thorac Cardiovasc Surg; 1985 Oct; 33(5):279-82. PubMed ID: 2416081
[TBL] [Abstract][Full Text] [Related]
14. Circuit and protocol for hypoxic hyperthermic isolated limb perfusion to treat malignant melanoma.
Innet LM; Haripershad V; Van Den Berg J; Cooper L
Perfusion; 2001 Jul; 16(4):325-30. PubMed ID: 11486853
[TBL] [Abstract][Full Text] [Related]
15. Blood conservation with membrane oxygenators and dipyridamole.
Teoh KH; Christakis GT; Weisel RD; Madonik MM; Ivanov J; Wong PY; Mee AV; Levitt D; Benak A; Reilly P
Ann Thorac Surg; 1987 Jul; 44(1):40-7. PubMed ID: 3300583
[TBL] [Abstract][Full Text] [Related]
16. Clinical comparison between membrane and bubble oxygenators in cardiopulmonary bypass.
Fenchel G; Seybold-Epting W; Schmidt K; Stunkat R; Hoffmeister HE
J Cardiovasc Surg (Torino); 1979; 20(4):419-22. PubMed ID: 479280
[TBL] [Abstract][Full Text] [Related]
17. A prospective comparison of bubble and membrane oxygenators in short and long perfusions.
Dhumale R; Lake S; Pepper J
Eur J Cardiothorac Surg; 1987; 1(1):20-2. PubMed ID: 3273207
[TBL] [Abstract][Full Text] [Related]
18. A comparison of membrane and bubble oxygenation as used in cardiopulmonary bypass in patients. The importance of pericardial blood as a source of hemolysis.
Siderys H; Herod GT; Halbrook H; Pittman JN; Rubush JL; Kasebaker V; Berry GR
J Thorac Cardiovasc Surg; 1975 May; 69(5):708-12. PubMed ID: 1079293
[TBL] [Abstract][Full Text] [Related]
19. Impact of oxygenator design on hemolysis, shear stress, and white blood cell and platelet counts.
De Somer D; Foubert L; Vanackere M; Dujardin D; Delanghe J; Van Nooten G
J Cardiothorac Vasc Anesth; 1996 Dec; 10(7):884-9. PubMed ID: 8969395
[TBL] [Abstract][Full Text] [Related]
20. Miniature membrane oxygenator for use in neonatal ECMO.
Katayama M; Miyasaka K; Hirose I; Shimada M; Mimura R; Akasu H
ASAIO Trans; 1991; 37(3):M407-8. PubMed ID: 1751211
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]