100 related articles for article (PubMed ID: 7965874)
1. Re: A paper entitled "Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurement," by JE Sanders and CH Daly, published in the Journal of Rehabilitation Research and Development, Vol. 30 No. 2, pp 191-204, 1993.
Ziegelhofer PF
J Rehabil Res Dev; 1994; 31(2):175-7. PubMed ID: 7965874
[No Abstract] [Full Text] [Related]
2. Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket.
Lee WC; Zhang M; Jia X; Cheung JT
Med Eng Phys; 2004 Oct; 26(8):655-62. PubMed ID: 15471693
[TBL] [Abstract][Full Text] [Related]
3. Nonlinear elastic material property estimation of lower extremity residual limb tissues.
Tönük E; Silver-Thorn MB
IEEE Trans Neural Syst Rehabil Eng; 2003 Mar; 11(1):43-53. PubMed ID: 12797725
[TBL] [Abstract][Full Text] [Related]
4. Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements.
Sanders JE; Daly CH
J Rehabil Res Dev; 1993; 30(2):191-204. PubMed ID: 8035348
[TBL] [Abstract][Full Text] [Related]
5. Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets.
Beil TL; Street GM; Covey SJ
J Rehabil Res Dev; 2002; 39(6):693-700. PubMed ID: 17943671
[TBL] [Abstract][Full Text] [Related]
6. [Three-dimensional finite element analyses on the transtibial residual limb and its prosthetic socket].
Zhang M; Mak AF; Fan Y
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2000 Dec; 17(4):403-6. PubMed ID: 11211825
[TBL] [Abstract][Full Text] [Related]
7. State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: a review.
Mak AF; Zhang M; Boone DA
J Rehabil Res Dev; 2001; 38(2):161-74. PubMed ID: 11392649
[TBL] [Abstract][Full Text] [Related]
8. Modeling the interactions between a prosthetic socket, polyurethane liners and the residual limb in transtibial amputees using non-linear finite element analysis.
Simpson G; Fisher C; Wright DK
Biomed Sci Instrum; 2001; 37():343-7. PubMed ID: 11347414
[TBL] [Abstract][Full Text] [Related]
9. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting.
Portnoy S; Yarnitzky G; Yizhar Z; Kristal A; Oppenheim U; Siev-Ner I; Gefen A
Ann Biomed Eng; 2007 Jan; 35(1):120-35. PubMed ID: 17120139
[TBL] [Abstract][Full Text] [Related]
10. Finite element analysis of donning procedure of a prosthetic transfemoral socket.
Lacroix D; Patiño JF
Ann Biomed Eng; 2011 Dec; 39(12):2972-83. PubMed ID: 21887588
[TBL] [Abstract][Full Text] [Related]
11. Pneumatic Airleg prosthesis: report of 200 cases.
Bonner FJ; Green RF
Arch Phys Med Rehabil; 1982 Aug; 63(8):383-5. PubMed ID: 7115032
[TBL] [Abstract][Full Text] [Related]
12. Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects.
Jia X; Zhang M; Lee WC
J Biomech; 2004 Sep; 37(9):1371-7. PubMed ID: 15275844
[TBL] [Abstract][Full Text] [Related]
13. Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket.
Silver-Thorn MB; Childress DS
J Rehabil Res Dev; 1997 Apr; 34(2):171-86. PubMed ID: 9108344
[TBL] [Abstract][Full Text] [Related]
14. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.
Zhang L; Zhu M; Shen L; Zheng F
Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1270-3. PubMed ID: 24109926
[TBL] [Abstract][Full Text] [Related]
15. [Possibilities for optimizing prosthetic management of leg amputees using quantitative movement analysis].
Boenick U
Biomed Tech (Berl); 1993 Jun; 38(6):144-52. PubMed ID: 8364145
[TBL] [Abstract][Full Text] [Related]
16. FE stress analysis of the interface between the bone and an osseointegrated implant for amputees--implications to refine the rehabilitation program.
Lee WC; Doocey JM; Brånemark R; Adam CJ; Evans JH; Pearcy MJ; Frossard LA
Clin Biomech (Bristol, Avon); 2008 Dec; 23(10):1243-50. PubMed ID: 18809231
[TBL] [Abstract][Full Text] [Related]
17. Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket.
Zhang M; Roberts C
Med Eng Phys; 2000 Nov; 22(9):607-12. PubMed ID: 11259929
[TBL] [Abstract][Full Text] [Related]
18. Development of a finite element model of a transtibial socket liner--an initial study.
Fisher C; Simpson G; Reynolds D
Biomed Sci Instrum; 1999; 35():39-44. PubMed ID: 11143383
[TBL] [Abstract][Full Text] [Related]
19. State-of-the-art methods for geometric and biomechanical assessments of residual limbs: a review.
Zheng YP; Mak AF; Leung AK
J Rehabil Res Dev; 2001; 38(5):487-504. PubMed ID: 11732827
[TBL] [Abstract][Full Text] [Related]
20. Below knee prosthetic socket designs and suspension systems.
Edwards ML
Phys Med Rehabil Clin N Am; 2000 Aug; 11(3):585-93, vi. PubMed ID: 10989480
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]