These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 7967833)

  • 1. Estimation of 2-D blood flow velocity map from cine-angiograms: algorithm using overlapping block set and illustration of vortex flow in abdominal aneurysm.
    Sugimoto N; Uyama C; Sugahara T; Yanagihara Y
    Med Biol Eng Comput; 1994 Jul; 32(4 Suppl):S178-84. PubMed ID: 7967833
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of a novel particle tracking algorithm in the flow visualization of an artificial abdominal aortic aneurysm.
    Zhang Y; Wang Y; He W; Yang B
    Biomed Mater Eng; 2014; 24(6):2585-91. PubMed ID: 25226961
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Regularization of flow streamlines in multislice phase-contrast MR imaging.
    Fatouraee N; Amini AA
    IEEE Trans Med Imaging; 2003 Jun; 22(6):699-709. PubMed ID: 12872945
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of an abdominal aortic velocity waveform in patients with abdominal aortic aneurysm.
    Fraser KH; Meagher S; Blake JR; Easson WJ; Hoskins PR
    Ultrasound Med Biol; 2008 Jan; 34(1):73-80. PubMed ID: 17689855
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemodynamics of the normal aorta compared to fusiform and saccular abdominal aortic aneurysms with emphasis on a potential thrombus formation mechanism.
    Biasetti J; Gasser TC; Auer M; Hedin U; Labruto F
    Ann Biomed Eng; 2010 Feb; 38(2):380-90. PubMed ID: 19936925
    [TBL] [Abstract][Full Text] [Related]  

  • 6. CFD and PTV steady flow investigation in an anatomically accurate abdominal aortic aneurysm.
    Boutsianis E; Guala M; Olgac U; Wildermuth S; Hoyer K; Ventikos Y; Poulikakos D
    J Biomech Eng; 2009 Jan; 131(1):011008. PubMed ID: 19045924
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of asymmetry in abdominal aortic aneurysms under physiologically realistic pulsatile flow conditions.
    Finol EA; Keyhani K; Amon CH
    J Biomech Eng; 2003 Apr; 125(2):207-17. PubMed ID: 12751282
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of the measured and predicted flowfield in a patient-specific model of an abdominal aortic aneurysm.
    O'Rourke MJ; McCullough JP
    Proc Inst Mech Eng H; 2008 Jul; 222(5):737-50. PubMed ID: 18756691
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of wall compliance on hemodynamics in models of abdominal aortic aneurysm.
    Gaillard E; Bergeron P; Deplano V
    J Endovasc Ther; 2007 Aug; 14(4):593-9. PubMed ID: 17696637
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Low wall shear stress predominates at sites of abdominal aortic aneurysm rupture.
    Boyd AJ; Kuhn DC; Lozowy RJ; Kulbisky GP
    J Vasc Surg; 2016 Jun; 63(6):1613-9. PubMed ID: 25752691
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fluid, solid and fluid-structure interaction simulations on patient-based abdominal aortic aneurysm models.
    Kelly S; O'Rourke M
    Proc Inst Mech Eng H; 2012 Apr; 226(4):288-304. PubMed ID: 22611869
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An image processing algorithm for the in-vivo quantification and visualization of septum motion in type III B - aortic dissections with cine magnetic resonance imaging.
    Karmonik C; Bismuth J; Davies MG; Younes HK; Lumsden AB
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():4391-4. PubMed ID: 19964359
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A numerical study of fluid-structure coupled effect of abdominal aortic aneurysm.
    Cong Y; Wang L; Liu X
    Biomed Mater Eng; 2015; 26 Suppl 1():S245-55. PubMed ID: 26406009
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Relationship Between Pulsatile Flow Impingement and Intraluminal Thrombus Deposition in Abdominal Aortic Aneurysms.
    Lozowy RJ; Kuhn DC; Ducas AA; Boyd AJ
    Cardiovasc Eng Technol; 2017 Mar; 8(1):57-69. PubMed ID: 27896659
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative Analysis of Vortical Blood Flow in the Thoracic Aorta Using 4D Phase Contrast MRI.
    von Spiczak J; Crelier G; Giese D; Kozerke S; Maintz D; Bunck AC
    PLoS One; 2015; 10(9):e0139025. PubMed ID: 26418327
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fluid-structure interaction effects on sac-blood pressure and wall stress in a stented aneurysm.
    Li Z; Kleinstreuer C
    J Biomech Eng; 2005 Aug; 127(4):662-71. PubMed ID: 16121537
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of arterial blood flow on walls of the abdominal aorta: distributions of wall shear stress and oscillatory shear index determined by phase-contrast magnetic resonance imaging.
    Sughimoto K; Shimamura Y; Tezuka C; Tsubota K; Liu H; Okumura K; Masuda Y; Haneishi H
    Heart Vessels; 2016 Jul; 31(7):1168-75. PubMed ID: 26481791
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping.
    Hope TA; Markl M; Wigström L; Alley MT; Miller DC; Herfkens RJ
    J Magn Reson Imaging; 2007 Dec; 26(6):1471-9. PubMed ID: 17968892
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An investigation of the relationship between hemodynamics and thrombus deposition within patient-specific models of abdominal aortic aneurysm.
    O'Rourke MJ; McCullough JP; Kelly S
    Proc Inst Mech Eng H; 2012 Jul; 226(7):548-64. PubMed ID: 22913102
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fluid-structure interaction in abdominal aortic aneurysms: effects of asymmetry and wall thickness.
    Scotti CM; Shkolnik AD; Muluk SC; Finol EA
    Biomed Eng Online; 2005 Nov; 4():64. PubMed ID: 16271141
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.