These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

60 related articles for article (PubMed ID: 796972)

  • 1. [Measurement of the heart minute volume by means of the ether dilution method].
    Bachofen H; Gurtner HP; Salzmann C
    Schweiz Med Wochenschr; 1976 Nov; 106(45):1551-3. PubMed ID: 796972
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of the saline-dilution method for measuring cardiac output by simultaneous measurement with a perivascular electromagnetic flowprobe.
    Voorhees WD; Bourland JD; Lamp ML; Mullikin JC; Geddes LA
    Med Instrum; 1985; 19(1):34-7. PubMed ID: 3157857
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of cardiac output without right heart catheterization: reliability, advantages, and limitations of a left-sided indicator dilution technique.
    van den Berg E; Pacifico A; Lange RA; Wheelan KR; Winniford MD; Hillis LD
    Cathet Cardiovasc Diagn; 1986; 12(3):205-8. PubMed ID: 3524851
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hypertonic-hyperoncotic solutions improve cardiac function in children after open-heart surgery.
    Schroth M; Plank C; Meissner U; Eberle KP; Weyand M; Cesnjevar R; Dötsch J; Rascher W
    Pediatrics; 2006 Jul; 118(1):e76-84. PubMed ID: 16751617
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Measurement of cardiac output using ether dilution (author's transl)].
    Suwa K; Meguro K; Ohtake K; Yamamura H
    Kokyu To Junkan; 1980 Nov; 28(11):1277-81. PubMed ID: 7017862
    [No Abstract]   [Full Text] [Related]  

  • 6. [The measurement of cardiac output using ether or ether and nitrous oxide (author's transl)].
    Meguro K
    Masui; 1980 Nov; 29(12):1450-62. PubMed ID: 7007681
    [No Abstract]   [Full Text] [Related]  

  • 7. A new constant infusion radioisotopic technique for the noninvasive determination of cardiac output.
    Berman DS; Salel AF; DeNardo GL; Bell GB; Scheibe PO; Jackson PE; Mason DT
    Med Instrum; 1976; 10(4):195-204. PubMed ID: 785164
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cardiac output measurement by indicator dilution.
    Chamberlain JH
    Biomed Eng; 1975 Mar; 10(3):92-7. PubMed ID: 1092374
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The electrical impedance indicator dilution method in studying the basic hemodynamic parameters during dialysis].
    Maksimenko VA; Belorusov OS; Krivitskiĭ NM; Ho ZZ; Shifris SV; Kislukhin VV
    Urol Nefrol (Mosk); 1991; (4):55-7. PubMed ID: 1949419
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effective mass concept: theoretical and quantitative analysis of the forbidden indicator phenomenon.
    Voorhees WD; Geddes LA; Bourland JD; Fearnot NE; Jones JT
    Med Instrum; 1986; 20(3):130-4. PubMed ID: 3523175
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of reduced rebreathing time, in spontaneously breathing patients, on respiratory effort and accuracy in cardiac output measurement when using a partial carbon dioxide rebreathing technique: a prospective observational study.
    Tachibana K; Imanaka H; Takeuchi M; Nishida T; Takauchi Y; Nishimura M
    Crit Care; 2005 Oct; 9(5):R569-74. PubMed ID: 16277720
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Thermodilution procedure for cardiac output determination using an automatic method].
    Röder F
    Acta Biol Med Ger; 1974; 32(6):665-73. PubMed ID: 4278953
    [No Abstract]   [Full Text] [Related]  

  • 13. Single breath cardiac output--enhanced sampling and analysis techniques.
    Deno NS; Kamon E; Ultman JS
    Aviat Space Environ Med; 1983 Nov; 54(11):1009-14. PubMed ID: 6418132
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Automated cardiac output measurement by color Doppler echocardiography].
    Yagi T; Yoshida K; Hozumi T; Akasaka T; Shakudo M; Takagi T; Kaji S; Kawamoto T; Ogata Y; Kawai J; Morioka S; Yoshikawa J
    J Cardiol; 1998 Apr; 31(4):223-6. PubMed ID: 9594371
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measuring circulating blood volume using infused hemoglobin-based oxygen carrier (oxyglobin) as an indicator: verification in a canine hypovolemia model.
    Jahr JS; Lurie F; Bezdikian V; Driessen B; Gunther RA
    Am J Ther; 2008; 15(2):98-101. PubMed ID: 18356627
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Definition of mixing rate of indicator by indicator dilution method: evaluation of relationship between mixing rate of indicator and cardiac output determination.
    Taniguchi K; Kirigaya H; Itoh H; Takamoto T; Iesaka Y; Takeuchi J
    Bull Tokyo Med Dent Univ; 1986 Jun; 33(2):41-8. PubMed ID: 3552278
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Determining circulatory minute volume by the rebreathing method].
    Vinitskaia RS; Koganova NA
    Biull Eksp Biol Med; 1977 Feb; 83(2):245-7. PubMed ID: 856347
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of cardiac output in man with a nonrecirculating indicator.
    Wittenberg SM; Klocke FJ; Greene DG; Bunnell IL; Falsetti HL; Zizzi JA
    J Clin Invest; 1971 Jul; 50(7):1466-72. PubMed ID: 4932984
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Comparative evaluation of the radiocardiographic and the dye dilution methods of determining cardiac output and circulating blood volume].
    Beloev I; Sheĭretova E; Kaloianova A
    Vutr Boles; 1980; 19(1):40-4. PubMed ID: 6989114
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of noninvasive cardiac output measured by use of partial carbon dioxide rebreathing or the lithium dilution method in anesthetized foals.
    Valverde A; Giguère S; Morey TE; Sanchez LC; Shih A
    Am J Vet Res; 2007 Feb; 68(2):141-7. PubMed ID: 17269878
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.