These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
463 related articles for article (PubMed ID: 7978175)
1. [The effect of changes in lung compliance on ventilation in newborns. Results of animal experiments with two different respirators]. Schirmer U; Schreiber M; Goertz A; Schütz W; Rockemann M; Georgieff M Anaesthesist; 1994 Aug; 43(8):521-7. PubMed ID: 7978175 [TBL] [Abstract][Full Text] [Related]
2. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment]. Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533 [TBL] [Abstract][Full Text] [Related]
3. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator]. Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078 [TBL] [Abstract][Full Text] [Related]
4. Improved flow and pressure capabilities of the Datex-Ohmeda SmartVent anesthesia ventilator. Katz JA; Kallet RH; Alonso JA; Marks JD J Clin Anesth; 2000 Feb; 12(1):40-7. PubMed ID: 10773507 [TBL] [Abstract][Full Text] [Related]
5. [The effect of different types of anesthetic respirators on oxygenation and ventilation in infants during short-term anesthesia. A study using transcutaneous PO2 and PCO2 monitoring]. Scheiber G; Hess W; Marichal A Anaesthesist; 1994 Aug; 43(8):510-20. PubMed ID: 7978174 [TBL] [Abstract][Full Text] [Related]
6. [Efficacy of two-lung ventilation with different tidal volume assisted by CO Sun YL; Sun L; Li TK; Lyu SG; Lu XH Zhonghua Yi Xue Za Zhi; 2021 Sep; 101(35):2787-2791. PubMed ID: 34551495 [No Abstract] [Full Text] [Related]
7. [Clinical application of adaptive minute ventilation + IntelliCycle ventilation mode in patients with mild-to-moderate acute respiratory distress syndrome]. Liu Z; Di X; Zhong L; Su Z; Xu B; Zhang X; Liang Z; Zhao G; Hu Z Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2020 Jan; 32(1):20-25. PubMed ID: 32148226 [TBL] [Abstract][Full Text] [Related]
8. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Bachiller PR; McDonough JM; Feldman JM Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850 [TBL] [Abstract][Full Text] [Related]
9. Lung aeration during ventilation after recruitment guided by tidal elimination of carbon dioxide and dynamic compliance was better than after end-tidal carbon dioxide targeted ventilation: a computed tomography study in surfactant-depleted piglets. Hanson A; Göthberg S; Nilsson K; Hedenstierna G Pediatr Crit Care Med; 2011 Nov; 12(6):e362-8. PubMed ID: 21263364 [TBL] [Abstract][Full Text] [Related]
10. Rebreathing improves accuracy of ventilatory monitoring. Bowie JR; Knox P; Downs JB; Smith RA J Clin Monit; 1995 Nov; 11(6):354-7. PubMed ID: 8576717 [TBL] [Abstract][Full Text] [Related]
11. Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses. Schmalisch G; Schmidt M; Proquitté H; Foitzik B; Rüdiger M; Wauer RR Crit Care Med; 2003 May; 31(5):1435-41. PubMed ID: 12771615 [TBL] [Abstract][Full Text] [Related]
12. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode. Tung A; Drum ML; Morgan S J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723 [TBL] [Abstract][Full Text] [Related]
13. Effects of pneumoperitoneum on intraoperative pulmonary mechanics and gas exchange during laparoscopic gastric bypass. Nguyen NT; Anderson JT; Budd M; Fleming NW; Ho HS; Jahr J; Stevens CM; Wolfe BM Surg Endosc; 2004 Jan; 18(1):64-71. PubMed ID: 14625752 [TBL] [Abstract][Full Text] [Related]
14. Arterial to end-tidal PCO2 difference varies with different ventilatory conditions during steady state hypercapnia in the rat. Tojima H; Kuriyama T; Fukuda Y Jpn J Physiol; 1988; 38(4):445-57. PubMed ID: 3148777 [TBL] [Abstract][Full Text] [Related]
15. Effect of low tidal volume with PEEP on respiratory function in infants undergoing one-lung ventilation. Liu J; Liao X; Li Y; Luo H; Huang W; Peng L; Fang Q; Hu Z Anaesthesist; 2017 Sep; 66(9):667-671. PubMed ID: 28656353 [TBL] [Abstract][Full Text] [Related]
16. [Effects of tracheal gas insufflation on blood gases and respiratory mechanics in acute hypercapnia rabbits]. Zhang B; Liu Y Zhonghua Jie He He Hu Xi Za Zhi; 1999 Sep; 22(9):523-7. PubMed ID: 11776762 [TBL] [Abstract][Full Text] [Related]
17. [The behavior of arterial and mixed venous oxygen and carbon dioxide partial pressure and the pH value during and following intubation apnoea. Studies on the occurrence of the Christiansen-Douglas-Haldane effect]. Merkelbach D; Brandt L; Mertzlufft F Anaesthesist; 1993 Oct; 42(10):691-701. PubMed ID: 8250203 [TBL] [Abstract][Full Text] [Related]
18. Pressure support ventilation in patients with acute lung injury. Cereda M; Foti G; Marcora B; Gili M; Giacomini M; Sparacino ME; Pesenti A Crit Care Med; 2000 May; 28(5):1269-75. PubMed ID: 10834664 [TBL] [Abstract][Full Text] [Related]
19. Central contribution to hypoventilation during severe inspiratory resistive loads. Kanter RK; Fordyce WE Crit Care Med; 1993 Dec; 21(12):1915-22. PubMed ID: 8252898 [TBL] [Abstract][Full Text] [Related]