These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. The climatisation of anesthetic gases under conditions of high flow to low flow. Kleemann PP Acta Anaesthesiol Belg; 1990; 41(3):189-200. PubMed ID: 2260425 [TBL] [Abstract][Full Text] [Related]
5. The humidity in a Dräger Primus anesthesia workstation using low or high fresh gas flow and with or without a heat and moisture exchanger in pediatric patients. Bicalho GP; Braz LG; de Jesus LSB; Pedigone CMC; de Carvalho LR; Módolo NSP; Braz JRC Anesth Analg; 2014 Oct; 119(4):926-931. PubMed ID: 25010823 [TBL] [Abstract][Full Text] [Related]
6. Effects of different fresh gas flows with or without a heat and moisture exchanger on inhaled gas humidity in adults undergoing general anaesthesia: A systematic review and meta-analysis of randomised controlled trials. Braz JRC; Braz MG; Hayashi Y; Martins RHG; Betini M; Braz LG; El Dib R Eur J Anaesthesiol; 2017 Aug; 34(8):515-525. PubMed ID: 28403017 [TBL] [Abstract][Full Text] [Related]
8. The effect of heat and moisture exchanger on humidity and body temperature in a low-flow anaesthesia system. Johansson A; Lundberg D; Luttropp HH Acta Anaesthesiol Scand; 2003 May; 47(5):564-8. PubMed ID: 12699514 [TBL] [Abstract][Full Text] [Related]
9. Fresh gas flow and carbon dioxide rebreathing in a low pressure semi-open anaesthesia system. Tweed WA; Amatya R; Lekhak BD Can J Anaesth; 1993 Nov; 40(11):1096-101. PubMed ID: 8269574 [TBL] [Abstract][Full Text] [Related]
10. [Improved climatization of anesthetic gases by modifying the Sulla 808 V anesthesia equipment]. Kleemann PP Anaesthesiol Reanim; 1995; 20(3):71-5. PubMed ID: 8526962 [TBL] [Abstract][Full Text] [Related]
11. Comparison of the effects of low-flow and high-flow inhalational anaesthesia with nitrous oxide and desflurane on mucociliary activity and pulmonary function tests. Bilgi M; Goksu S; Mizrak A; Cevik C; Gul R; Koruk S; Sahin L Eur J Anaesthesiol; 2011 Apr; 28(4):279-83. PubMed ID: 21119518 [TBL] [Abstract][Full Text] [Related]
12. The effect of heat and moisture exchanger and gas flow on humidity and temperature in a circle anaesthetic system. Poopalalingam R; Goh MH; Chan YW Singapore Med J; 2002 Nov; 43(11):563-5. PubMed ID: 12680524 [TBL] [Abstract][Full Text] [Related]
13. The benefit of using a heat and moisture exchanger during short operations in young children. Monrigal JP; Granry JC Paediatr Anaesth; 1997; 7(4):295-300. PubMed ID: 9243686 [TBL] [Abstract][Full Text] [Related]
14. Consequences of Pausing Heated Humidification During Invasive Ventilation. Lellouche F; Bouchard PA Respir Care; 2024 Sep; 69(10):1239-1244. PubMed ID: 39079722 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of the efficiency of heat and moisture exchangers during paediatric anaesthesia. Luchetti M; Pigna A; Gentili A; Marraro G Paediatr Anaesth; 1999; 9(1):39-45. PubMed ID: 10712714 [TBL] [Abstract][Full Text] [Related]
17. The effect of heat-moisture exchanger and closed-circuit technique on airway climate during desflurane anesthesia. Lu CC; Ho ST; Liaw WJ; Chen RM; Chen TL; Lin CY J Anesth; 2008; 22(1):7-12. PubMed ID: 18306007 [TBL] [Abstract][Full Text] [Related]
18. The effect of a heat and moisture exchanger on humidity in a low-flow anaesthesia system. Henriksson BA; Sundling J; Hellman A Anaesthesia; 1997 Feb; 52(2):144-9. PubMed ID: 9059098 [TBL] [Abstract][Full Text] [Related]
19. [Fresh gas flow and artificial respiration in anesthesia. Technical requirements for the adequate use of rebreathing systems]. Baum J; Sachs G Anasth Intensivther Notfallmed; 1990 Feb; 25(1):72-8. PubMed ID: 2309993 [TBL] [Abstract][Full Text] [Related]
20. Techniques of mechanical ventilation in closed and low flow systems. Lockwood GG Anaesth Intensive Care; 1994 Aug; 22(4):419-25. PubMed ID: 7978207 [No Abstract] [Full Text] [Related] [Next] [New Search]