153 related articles for article (PubMed ID: 7982609)
1. [Evaluation of effectiveness of experimental device "Elf" in development of local non-bacterial zone].
Nedachin AE; Vlodavets VV; Budkevich LI; Dmitrieva RA; Doskina TV; Sukhareva EA; Teplovodskiĭ SKh
Gig Sanit; 1994 Jun; (6):11-2. PubMed ID: 7982609
[No Abstract] [Full Text] [Related]
2. [Bacterial contamination of indoor air as a function of air exchange].
Russenberger HJ; Wanner HU
Zentralbl Bakteriol Orig A; 1974; 227(1-4):564-7. PubMed ID: 4154642
[No Abstract] [Full Text] [Related]
3. Engineering controls for clean air in the office environment.
Ellenbecker MJ
Clin Chest Med; 1992 Jun; 13(2):193-9. PubMed ID: 1511548
[TBL] [Abstract][Full Text] [Related]
4. [Effectiveness of the maintenance operations on the air conditioning systems of a university building in relation to the microbiological quality of the air indoor].
De Filippis P; Spinaci A; Coia M; Maggi O; Panà A
Ig Sanita Pubbl; 2003; 59(6):365-72. PubMed ID: 15116148
[TBL] [Abstract][Full Text] [Related]
5. The risks associated with HVAC drip pans.
Health Devices; 1996 Jan; 25(1):43. PubMed ID: 8932657
[No Abstract] [Full Text] [Related]
6. Security of HVAC air intakes.
Burton DJ
Occup Health Saf; 2002 Feb; 71(2):24. PubMed ID: 12966769
[No Abstract] [Full Text] [Related]
7. Environmental controls. Part 1: Air cleaners.
Ferguson BJ
Ear Nose Throat J; 1995 Apr; 74(4):224-5, 228. PubMed ID: 7758420
[No Abstract] [Full Text] [Related]
8. Design and development of ultraviolet germicidal irradiation device for controlling airborne bacteria in the workplace.
Yoosook W; Kongtip P; Chantanakul S
J Med Assoc Thai; 2009 Dec; 92 Suppl 7():S142-7. PubMed ID: 20232567
[TBL] [Abstract][Full Text] [Related]
9. In with the good air.
Streifel AJ
Infect Control Hosp Epidemiol; 2002 Sep; 23(9):488-90. PubMed ID: 12269443
[No Abstract] [Full Text] [Related]
10. [Use of ultraviolet air decontamination in the ventilating system at food industry enterprises].
Dolgaev SI
Gig Sanit; 2008; (5):50-1. PubMed ID: 19069396
[No Abstract] [Full Text] [Related]
11. [Hospitals location and indoor air microbiological quality].
Krogulski A
Rocz Panstw Zakl Hig; 2008; 59(1):97-102. PubMed ID: 18666627
[TBL] [Abstract][Full Text] [Related]
12. [Efficiency evaluation of high-dispersion aerosol generators operation mode in closed premises].
Putyrskiĭ VP; Iampol'skiĭ VA
Gig Sanit; 2010; (1):94-5. PubMed ID: 20373724
[TBL] [Abstract][Full Text] [Related]
13. [The design of air purification system and its effect on surgical ICU].
Su L; Li H; Bai T
Zhonghua Wai Ke Za Zhi; 1996 May; 34(5):291-3. PubMed ID: 9387706
[TBL] [Abstract][Full Text] [Related]
14. Alison Bell Memorial Writer's Award. Something in the air.
Howell G
Br J Theatre Nurs; 1998 Apr; 8(1):29-32. PubMed ID: 9592416
[No Abstract] [Full Text] [Related]
15. [Evaluation of effectiveness of porous metal ceramics for air purification].
Kurguzkin MG; Rybakov VK; Grebnev VL
Gig Sanit; 1994 Jan; (1):6-7. PubMed ID: 8168713
[TBL] [Abstract][Full Text] [Related]
16. [A device for elimination of microorganisms from the air].
Kotenok IaF; Kopysov VA
Gig Sanit; 1990 Jul; (7):68-70. PubMed ID: 2227514
[No Abstract] [Full Text] [Related]
17. [Air cleaning equipment: its effect upon the quality of indoor air].
Klotz F; Wanner HU
Zentralbl Bakteriol Orig A; 1974; 227(1-4):559-63. PubMed ID: 4154640
[No Abstract] [Full Text] [Related]
18. [Comments on the problem of Legionella in Germany].
Seidel K
Schriftenr Ver Wasser Boden Lufthyg; 1993; 91():253-8. PubMed ID: 8235482
[No Abstract] [Full Text] [Related]
19. Portable air cleaners.
Burton J
Occup Health Saf; 2006 Jan; 75(1):22, 24. PubMed ID: 16447838
[No Abstract] [Full Text] [Related]
20. [A promising method of hygienic evaluation of air pollution inside the modules of the international space station by hydrazine derivatives].
Mikos KN; Mukhamedieva LN; Pakhomova AA; Ul'ianov AV; Serdiuk TM; Buriak AK
Aviakosm Ekolog Med; 2009; 43(2):53-7. PubMed ID: 19621805
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]