BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 7992910)

  • 1. Thermoregulatory and anesthetic-induced alterations in the differences among femoral, radial, and oscillometric blood pressures.
    Hynson JM; Sessler DI; Moayeri A; Katz JA
    Anesthesiology; 1994 Dec; 81(6):1411-21. PubMed ID: 7992910
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Thermoregulatory vasoconstriction increases the difference between femoral and radial arterial pressures.
    Urzua J; Sessler DI; Meneses G; Sacco CM; Canessa R; Lema G
    J Clin Monit; 1994 Jul; 10(4):229-36. PubMed ID: 7931452
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of preinduction warming on temperature and blood pressure during propofol/nitrous oxide anesthesia.
    Hynson JM; Sessler DI; Moayeri A; McGuire J; Schroeder M
    Anesthesiology; 1993 Aug; 79(2):219-28, discussion 21A-22A. PubMed ID: 8342834
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radial artery diameter decreases with increased femoral to radial arterial pressure gradient during cardiopulmonary bypass.
    Baba T; Goto T; Yoshitake A; Shibata Y
    Anesth Analg; 1997 Aug; 85(2):252-8. PubMed ID: 9249096
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reliability of the radial arterial pressure during anesthesia. Is wrist compression a possible diagnostic test?
    Pauca AL; Wallenhaupt SL; Kon ND
    Chest; 1994 Jan; 105(1):69-75. PubMed ID: 8275788
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thermoregulatory vasoconstriction does not impede core warming during cutaneous heating.
    Clough D; Kurz A; Sessler DI; Christensen R; Xiong J
    Anesthesiology; 1996 Aug; 85(2):281-8. PubMed ID: 8712443
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Usefulness of brachial artery pressure with forearm compression as arterial pressure monitoring after cardiopulmonary bypass].
    Katsuno M
    Masui; 1996 Jan; 45(1):77-81. PubMed ID: 8865729
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pressure difference between radial and femoral artery pressure in minimally invasive cardiac surgery using retrograde perfusion.
    Nakamura Y; Emmanuel S; Shikata F; Shirai C; Ito Y; Kuroda M
    Int J Artif Organs; 2018 Oct; 41(10):635-643. PubMed ID: 29998763
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thermoregulatory vasodilation increases the venous partial pressure of oxygen.
    Tayefeh F; Kurz A; Sessler DI; Lawson CA; Ikeda T; Marder D
    Anesth Analg; 1997 Sep; 85(3):657-62. PubMed ID: 9296426
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Propofol causes a dose-dependent decrease in the thermoregulatory threshold for vasoconstriction but has little effect on sweating.
    Leslie K; Sessler DI; Bjorksten AR; Ozaki M; Matsukawa T; Schroeder M; Lin S
    Anesthesiology; 1994 Aug; 81(2):353-60. PubMed ID: 8053585
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radial mean arterial pressure reliably reflects femoral mean arterial pressure in uncomplicated pediatric cardiac surgery.
    Cetin S; Pirat A; Kundakci A; Camkiran A; Zeyneloglu P; Ozkan M; Arslan G
    J Cardiothorac Vasc Anesth; 2014 Feb; 28(1):76-83. PubMed ID: 24008165
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The thermoregulatory threshold during surgery with propofol-nitrous oxide anaesthesia].
    Lin CS; Lin IS; Liu CH; Wang CF; Wu HS; Liu CG; Chen LW
    Acta Anaesthesiol Sin; 1995 Mar; 33(1):15-20. PubMed ID: 7788193
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radial artery tonometry: moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement.
    Weiss BM; Spahn DR; Rahmig H; Rohling R; Pasch T
    Br J Anaesth; 1996 Mar; 76(3):405-11. PubMed ID: 8785142
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of a conical cuff on the forearm for estimating radial artery blood pressure.
    Hersh LT; Sesing JC; Luczyk WJ; Friedman BA; Zhou S; Batchelder PB
    Blood Press Monit; 2014 Feb; 19(1):38-45. PubMed ID: 24217368
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of radial arterial pressure measurement during surgery under controlled hypotension.
    Yazigi A; Madi-Jebara S; Haddad F; Hayek G; Jawish D
    Acta Anaesthesiol Scand; 2002 Feb; 46(2):173-5. PubMed ID: 11942865
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous non-invasive blood pressure monitoring by brachial artery displacement method in high-risk surgical patients.
    Weiss BM; Spahn DR; Keller E; Seifert B; Pasch T
    Eur J Anaesthesiol; 1995 Nov; 12(6):555-63. PubMed ID: 8665877
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thermoregulatory vasoconstriction during isoflurane anesthesia minimally decreases cutaneous heat loss.
    Sessler DI; McGuire J; Hynson J; Moayeri A; Heier T
    Anesthesiology; 1992 May; 76(5):670-5. PubMed ID: 1575332
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-temperature estimates by cutaneous liquid-crystal thermometers.
    Ikeda T; Sessler DI; Marder D; Xiong J
    Anesthesiology; 1997 Mar; 86(3):603-12. PubMed ID: 9066326
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thermoregulatory vasoconstriction during propofol/nitrous oxide anesthesia in humans: threshold and oxyhemoglobin saturation.
    Hynson JM; Sessler DI; Belani K; Washington D; McGuire J; Merrifield B; Schroeder M; Moayeri A; Crankshaw D; Hudson S
    Anesth Analg; 1992 Dec; 75(6):947-52. PubMed ID: 1443713
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Blood pressure after cardiopulmonary bypass: which technique is accurate?
    Thrush DN; Steighner ML; Räsänen J; Vijayanagar R
    J Cardiothorac Vasc Anesth; 1994 Jun; 8(3):269-72. PubMed ID: 8061259
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.