These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

247 related articles for article (PubMed ID: 7993947)

  • 21. Measuring cardiac output in critically Ill patients: disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods.
    Sherman MS; Kosinski R; Paz HL; Campbell D
    Cardiology; 1997; 88(1):19-25. PubMed ID: 8960620
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model.
    Rupérez M; López-Herce J; García C; Sánchez C; García E; Vigil D
    Pediatr Cardiol; 2004; 25(2):119-23. PubMed ID: 14681741
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of cardiac output measurements by arterial trans-cardiopulmonary and pulmonary arterial thermodilution with direct Fick in septic shock.
    Marx G; Schuerholz T; Sümpelmann R; Simon T; Leuwer M
    Eur J Anaesthesiol; 2005 Feb; 22(2):129-34. PubMed ID: 15816592
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Measuring cardiac output in infants with the Fick principle via oxygen consumption: animal experiment and clinical results].
    Pscheidl E; Buheitel G; Schywalsky M; Braun GG
    Klin Padiatr; 1994; 206(2):86-91. PubMed ID: 8196312
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Doppler cardiac output and left ventricular performance after cardiac surgery. Pulsed Doppler ascending aorta and pulmonary blood flows and left ventricular function using implanted microprobes.
    Fratacci MD; Payen D; Beloucif S; Laborde F
    Chest; 1992 Aug; 102(2):380-6. PubMed ID: 1643918
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Limitations of the metabolic rate meter for measuring oxygen consumption and cardiac output.
    Lange RA; Dehmer GJ; Wells PJ; Tate DA; Jain A; Flores ED; Nichols TC; Hillis LD
    Am J Cardiol; 1989 Oct; 64(12):783-6. PubMed ID: 2801530
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Reliability of cardiac output calculation by the fick principle and central venous oxygen saturation in emergency conditions.
    Weinbroum AA; Biderman P; Soffer D; Klausner JM; Szold O
    J Clin Monit Comput; 2008 Oct; 22(5):361-6. PubMed ID: 18946716
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution.
    Mellander M; Sabel KG; Caidahl K; Solymar L; Eriksson B
    Pediatr Cardiol; 1987; 8(4):241-6. PubMed ID: 3432113
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.
    Corley A; Barnett AG; Mullany D; Fraser JF
    Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A comparison of thermodilution and pulsed Doppler cardiac output measurement in critically ill children.
    Notterman DA; Castello FV; Steinberg C; Greenwald BM; O'Loughlin JE; Gold JP
    J Pediatr; 1989 Oct; 115(4):554-60. PubMed ID: 2795345
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Noninvasive measurement of cardiac output during surgery using a new continuous-wave Doppler esophageal probe.
    Kumar A; Minagoe S; Thangathurai D; Mikhail M; Novia D; Viljoen JF; Rahimtoola SH; Chandraratna PA
    Am J Cardiol; 1989 Oct; 64(12):793-8. PubMed ID: 2801532
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Simultaneous measurements of cardiac output by thermodilution, esophageal Doppler, and electrical impedance in anesthetized patients.
    Siegel LC; Shafer SL; Martinez GM; Ream AK; Scott JC
    J Cardiothorac Anesth; 1988 Oct; 2(5):590-5. PubMed ID: 17171947
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Noninvasive measurement of cardiac output by continuous-wave Doppler echocardiography: initial experience and review of the literature.
    Nishimura RA; Callahan MJ; Schaff HV; Ilstrup DM; Miller FA; Tajik AJ
    Mayo Clin Proc; 1984 Jul; 59(7):484-9. PubMed ID: 6738114
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation.
    Cigarroa RG; Lange RA; Williams RH; Bedotto JB; Hillis LD
    Am J Med; 1989 Apr; 86(4):417-20. PubMed ID: 2648822
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Two-dimensional pulsed Doppler echocardiographic estimates of cardiac output in man: sampling at the entrance to the main pulmonary artery].
    Kuwako K; Sakuma T; Matsuda M; Sekiguchi T; Sugishita Y; Ito I
    J Cardiogr; 1984 Dec; 14(4):841-50. PubMed ID: 6543881
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of Doppler echocardiography with thermodilution for assessing cardiac output in advanced congestive heart failure.
    Gola A; Pozzoli M; Capomolla S; Traversi E; Sanarico M; Cobelli F; Tavazzi L
    Am J Cardiol; 1996 Sep; 78(6):708-12. PubMed ID: 8831417
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Comparison of cardiac output measured continuously by thermodilution and calculated according to Fick's principle].
    Bizouarn P; Blanloeil Y; Pinaud M
    Ann Fr Anesth Reanim; 1994; 13(5):685-9. PubMed ID: 7733518
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Automatic cardiac output measurement (ACOM): clinical applications of a new noninvasive tool.
    Trindade PT; Brown P; Puryear JV; Popylisen S; Schnittger I
    Int J Card Imaging; 1998 Jun; 14(3):147-54. PubMed ID: 9813750
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Determination of cardiac output by Doppler echocardiography.
    Ihlen H; Amlie JP; Dale J; Forfang K; Nitter-Hauge S; Otterstad JE; Simonsen S; Myhre E
    Br Heart J; 1984 Jan; 51(1):54-60. PubMed ID: 6689921
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Continuous Fick cardiac output measurement during inhalation anesthesia].
    Sato K
    Hokkaido Igaku Zasshi; 1992 Mar; 67(2):161-73. PubMed ID: 1597299
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.