These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. [Role of high-definition and high frequency ultrasonography in determining tumor thickness in cutaneous malignant melanoma]. Solivetti FM; Thorel MF; Di Luca Sidozzi A; Bucher S; Donati P; Panichelli V Radiol Med; 1998 Dec; 96(6):558-61. PubMed ID: 10189916 [TBL] [Abstract][Full Text] [Related]
3. [Ranking of 20 MHz sonography of malignant melanoma and pigmented lesions in routine diagnosis]. Hoffmann K; Happe M; Schüller S; Stücker M; Wiesner M; Gottlöber P; Schwarz M; Strahler J; Neubauer H; Jung C; Petereit S; Welzel J; Brautzsch N; Bohmeyer J; Wohlrab J; Freitag M; Altmeyer P Ultraschall Med; 1999 Jun; 20(3):104-9. PubMed ID: 10444780 [TBL] [Abstract][Full Text] [Related]
4. High-frequency 30-MHz sonography in preoperative assessment of tumor thickness of primary melanoma: usefulness in determination of surgical margin and indication for sentinel lymph node biopsy. Hayashi K; Koga H; Uhara H; Saida T Int J Clin Oncol; 2009 Oct; 14(5):426-30. PubMed ID: 19856051 [TBL] [Abstract][Full Text] [Related]
5. Value of high-frequency US for preoperative assessment of skin tumors. Lassau N; Spatz A; Avril MF; Tardivon A; Margulis A; Mamelle G; Vanel D; Leclere J Radiographics; 1997; 17(6):1559-65. PubMed ID: 9397463 [TBL] [Abstract][Full Text] [Related]
6. Preoperative measurement of thickness of cutaneous melanoma using high-resolution 20 MHz ultrasound imaging: A monocenter prospective study and systematic review of the literature. Machet L; Belot V; Naouri M; Boka M; Mourtada Y; Giraudeau B; Laure B; Perrinaud A; Machet MC; Vaillant L Ultrasound Med Biol; 2009 Sep; 35(9):1411-20. PubMed ID: 19616369 [TBL] [Abstract][Full Text] [Related]
7. The Value of High-frequency 20 MHz Ultrasonography for Preoperative Measurement of Cutaneous Melanoma Thickness. Kozárová A; Kozár M; Tonhajzerová I; Pappová T; Minariková E Acta Dermatovenerol Croat; 2018 Apr; 26(1):15-20. PubMed ID: 29782294 [TBL] [Abstract][Full Text] [Related]
9. Does high-frequency (40-60 MHz) ultrasound imaging play a role in the clinical management of cutaneous melanoma? Semple JL; Gupta AK; From L; Harasiewicz KA; Sauder DN; Foster FS; Turnbull DH Ann Plast Surg; 1995 Jun; 34(6):599-605; discussion 606. PubMed ID: 7661536 [TBL] [Abstract][Full Text] [Related]
10. Prognostic value of high-frequency sonography and color Doppler sonography for the preoperative assessment of melanomas. Lassau N; Mercier S; Koscielny S; Avril MF; Margulis A; Mamelle G; Duvillard P; Leclère J AJR Am J Roentgenol; 1999 Feb; 172(2):457-61. PubMed ID: 9930803 [TBL] [Abstract][Full Text] [Related]
11. Preoperative assessment of skin tumor thickness and structure using 14-MHz ultrasound. Kučinskienė V; Samulėnienė D; Gineikienė A; Raišutis R; Kažys R; Valiukevičienė S Medicina (Kaunas); 2014; 50(3):150-5. PubMed ID: 25323542 [TBL] [Abstract][Full Text] [Related]
12. Preoperative 15-MHz ultrasound assessment of tumor thickness in malignant melanoma. Fernández Canedo I; de Troya Martín M; Fúnez Liébana R; Rivas Ruiz F; Blanco Eguren G; Blázquez Sánchez N Actas Dermosifiliogr; 2013 Apr; 104(3):227-31. PubMed ID: 22938997 [TBL] [Abstract][Full Text] [Related]
13. High frequency ultrasonography: a complementary diagnostic method in evaluation of primary cutaneous melanoma. Maj M; Warszawik-Hendzel O; Szymanska E; Walecka I; Rakowska A; Antczak-Marczak M; Kuna P; Kruszewski J; Nasierowska-Guttmejer A; Litniewski J; Nowicki A; Olszewska M; Rudnicka L G Ital Dermatol Venereol; 2015 Oct; 150(5):595-601. PubMed ID: 26333555 [TBL] [Abstract][Full Text] [Related]
14. Pre-operative ultrasound with a 12-15 MHz linear probe reliably differentiates between melanoma thicker and thinner than 1 mm. Music MM; Hertl K; Kadivec M; Pavlović MD; Hocevar M J Eur Acad Dermatol Venereol; 2010 Sep; 24(9):1105-8. PubMed ID: 20236207 [TBL] [Abstract][Full Text] [Related]
15. One-step surgical removal of cutaneous melanoma with surgical margins based on preoperative ultrasound measurement of the thickness of the melanoma. Chaput L; Laurent E; Pare A; Sallot A; Mourtada Y; Ossant F; Vaillant L; Patat F; Machet L Eur J Dermatol; 2018 Apr; 28(2):202-208. PubMed ID: 29620001 [TBL] [Abstract][Full Text] [Related]
16. Imaging of the skin with 20-MHz US. Fornage BD; McGavran MH; Duvic M; Waldron CA Radiology; 1993 Oct; 189(1):69-76. PubMed ID: 8372222 [TBL] [Abstract][Full Text] [Related]
17. High frequency ultrasonography of the skin and its role as an auxillary tool in diagnosis of benign and malignant cutaneous tumors--a comparison of two clinical cases. Dybiec E; Pietrzak A; Adamczyk M; Michalska-Jakubus M; Wawrzycki B; Lotti T; Rutkowski P; Krasowska D Acta Dermatovenerol Croat; 2015; 23(1):43-7. PubMed ID: 25969912 [TBL] [Abstract][Full Text] [Related]
18. Preoperative characterization of pigmented skin lesions by epiluminescence microscopy and high-frequency ultrasound. Dummer W; Blaheta HJ; Bastian BC; Schenk T; Bröcker EV; Remy W Arch Dermatol; 1995 Mar; 131(3):279-85. PubMed ID: 7887656 [TBL] [Abstract][Full Text] [Related]
19. Preoperative ultrasonic assessment of thin melanocytic skin lesions using a 100-MHz ultrasound transducer: a comparative study. Gambichler T; Moussa G; Bahrenberg K; Vogt M; Ermert H; Weyhe D; Altmeyer P; Hoffmann K Dermatol Surg; 2007 Jul; 33(7):818-24. PubMed ID: 17598847 [TBL] [Abstract][Full Text] [Related]
20. [Digital 20 mhz sonography of the skin in preoperative diagnosis]. Hoffmann K; el Gammal S; Matthes U; Altmeyer P Z Hautkr; 1989 Oct; 64(10):851-2, 855-8. PubMed ID: 2686243 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]