122 related articles for article (PubMed ID: 8000595)
1. Disc failure in a Björk-Shiley mitral prosthesis.
Van Sabben C; Griffin SC; Venn GE
J Heart Valve Dis; 1994 Sep; 3(5):581-2. PubMed ID: 8000595
[TBL] [Abstract][Full Text] [Related]
2. [Late malfunction of the Björk-Shiley valve prosthesis due to Delrin disc defacement].
Katsumata T; Shimakura T; Nakano H; Shimamura Y; Hoshino K; Harada T; Maejima F; Kohno H; Asakawa K; Yabuki A
Kyobu Geka; 1993 Nov; 46(12):1059-62. PubMed ID: 8230934
[TBL] [Abstract][Full Text] [Related]
3. Late results of valve replacement with the Björk-Shiley valve (1973 to 1982).
Orszulak TA; Schaff HV; DeSmet JM; Danielson GK; Pluth JR; Puga FJ
J Thorac Cardiovasc Surg; 1993 Feb; 105(2):302-12. PubMed ID: 8429659
[TBL] [Abstract][Full Text] [Related]
4. [Malfunction of the Björk-Shiley valve prosthesis due to disc defacement--report of two cases of successful reoperation].
Misumi H; Matsuo K; Ishihara K; Nakae S; Hashimoto A; Koyanagi H
Nihon Kyobu Geka Gakkai Zasshi; 1989 Mar; 37(3):522-8. PubMed ID: 2768926
[TBL] [Abstract][Full Text] [Related]
5. [Report of a case with re-mitral valve replacement for Björk-Shiley Delrin disc valve prosthesis--disc wear of the Delrin disc 20 years after implantation].
Abe M; Sakai A; Lin ZB; Hanayama N; Oosawa M
Nihon Kyobu Geka Gakkai Zasshi; 1996 Apr; 44(4):545-7. PubMed ID: 8666877
[TBL] [Abstract][Full Text] [Related]
6. [Minor strut fracture of the Björk-Shiley mitral valve].
Sugita T; Yasuda R; Watarida S; Onoe M; Tabata R; Mori A
Nihon Kyobu Geka Gakkai Zasshi; 1990 Jun; 38(6):1049-52. PubMed ID: 2204665
[TBL] [Abstract][Full Text] [Related]
7. [A case of minor strut fracture of Björk-Shiley Convexo-concave valve and a case of elective prophylactic reoperation].
Saito S; Tokunaga H; Takahashi S; Aomi S
Nihon Kyobu Geka Gakkai Zasshi; 1995 Jun; 43(6):852-6. PubMed ID: 7616033
[TBL] [Abstract][Full Text] [Related]
8. Fracture and embolization of a Björk-Shiley disc. Fatal failure of a prosthetic mitral valve.
Norenberg DD; Evans RW; Gundersen AE; Abellera RM
J Thorac Cardiovasc Surg; 1977 Dec; 74(6):925-7. PubMed ID: 303729
[TBL] [Abstract][Full Text] [Related]
9. [Emergency surgery for thrombosed Björk-Shiley mitral valve prosthesis].
Shigenobu M; Arai S; Aoki A; Hosotani A; Uchida H; Senoo Y; Teramoto S
Rinsho Kyobu Geka; 1989 Oct; 9(5):487-9. PubMed ID: 9301961
[TBL] [Abstract][Full Text] [Related]
10. Sound spectral analysis of prosthetic valvular clicks for diagnosis of thrombosed Björk-Shiley tilting standard disc valve prostheses.
Sato N; Miura M; Itoh T; Ohmi M; Haneda K; Mohri H; Nitta S; Tanaka M
J Thorac Cardiovasc Surg; 1993 Feb; 105(2):313-20. PubMed ID: 8429660
[TBL] [Abstract][Full Text] [Related]
11. [Long-term results over 20 years of aortic valve replacement with the standard Björk-Shiley prosthesis].
Valla J; Langanay T; Corbineau H; Sevray B; Chaperon J; Menestret P; Lelong B; Leguerrier A; Rioux C; Logeais Y
Arch Mal Coeur Vaiss; 1996 Sep; 89(9):1137-43. PubMed ID: 8952837
[TBL] [Abstract][Full Text] [Related]
12. [Bj"ork-Shiley heart vales at the Bern University Hospital. Long-term follow-up of 12 to 23 years after mitral and aortic valve replacement in 503 patients].
Stuber T; Kaufmann U; Kipfer B; Meier B
Praxis (Bern 1994); 1999 Feb; 88(9):355-63. PubMed ID: 10191683
[TBL] [Abstract][Full Text] [Related]
13. [A long-term evaluation of a Björk-Shiley valve prosthesis--eighteen year follow-up].
Kawashima Y; Nakano S; Kawamoto T
Rinsho Kyobu Geka; 1989 Aug; 9(4):335-8. PubMed ID: 9301937
[TBL] [Abstract][Full Text] [Related]
14. [Embolization of the disk in a Björk-Shiley mitral prosthesis: echocardiographic findings with a bidimensional technic].
García del Castillo H; Candell Riera J; Larrouse Pérez E; Murtra Ferré M; Soler Soler J
Rev Esp Cardiol; 1987; 40(4):288-9. PubMed ID: 3310147
[No Abstract] [Full Text] [Related]
15. [Intermittent stuck valve of a Björk-Shiley prosthetic valve in mitral position report of a case with successful repair].
Seo K; Osawa M; Matsuyama T; Kawai A
Rinsho Kyobu Geka; 1988 Aug; 8(4):395-7. PubMed ID: 9301860
[No Abstract] [Full Text] [Related]
16. [Sudden and fatal malfunction of a Björk-Shiley prosthesis in mitral position due to rupture of the ventricular bracket and disk embolization].
Casarotto D; Motta A; Fabbri A; Pugliese P; Muneretto C; Zanini M; Sheiban I
G Ital Cardiol; 1985 Apr; 15(4):451-3. PubMed ID: 4043647
[TBL] [Abstract][Full Text] [Related]
17. [Fatal rupture of the ventricular strut of a Björk-Shiley prosthesis in mitral position. Description of a case, review of the literature and elements of differential diagnosis].
Bortolini F; Rodella P; Cerqui F; Bellet C
G Ital Cardiol; 1987 Aug; 17(8):718-21. PubMed ID: 3319756
[TBL] [Abstract][Full Text] [Related]
18. Acute postoperative block of mechanical prostheses: incidence and treatment.
Santé P; Renzulli A; Festa M; Vitale N; Mollo A; Dialetto G; De Luca L
Cardiovasc Surg; 1994 Jun; 2(3):403-6. PubMed ID: 8049985
[TBL] [Abstract][Full Text] [Related]
19. [Successful emergency surgery in a material break in a Bjørk-Shiley mitral valve prosthesis].
Maas AH; van Swieten HA; Knaepen PJ; Defauw JJ; Brutel de la Rivière A; van Herpen G
Ned Tijdschr Geneeskd; 1986 May; 130(18):835-8. PubMed ID: 3713895
[No Abstract] [Full Text] [Related]
20. A comparative study in patients with Omnicarbon and Björk-Shiley heart valve replacement.
Otaki M
Int Surg; 1993; 78(4):338-42. PubMed ID: 8175264
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]