BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 8000595)

  • 1. Disc failure in a Björk-Shiley mitral prosthesis.
    Van Sabben C; Griffin SC; Venn GE
    J Heart Valve Dis; 1994 Sep; 3(5):581-2. PubMed ID: 8000595
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Late malfunction of the Björk-Shiley valve prosthesis due to Delrin disc defacement].
    Katsumata T; Shimakura T; Nakano H; Shimamura Y; Hoshino K; Harada T; Maejima F; Kohno H; Asakawa K; Yabuki A
    Kyobu Geka; 1993 Nov; 46(12):1059-62. PubMed ID: 8230934
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Late results of valve replacement with the Björk-Shiley valve (1973 to 1982).
    Orszulak TA; Schaff HV; DeSmet JM; Danielson GK; Pluth JR; Puga FJ
    J Thorac Cardiovasc Surg; 1993 Feb; 105(2):302-12. PubMed ID: 8429659
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Malfunction of the Björk-Shiley valve prosthesis due to disc defacement--report of two cases of successful reoperation].
    Misumi H; Matsuo K; Ishihara K; Nakae S; Hashimoto A; Koyanagi H
    Nihon Kyobu Geka Gakkai Zasshi; 1989 Mar; 37(3):522-8. PubMed ID: 2768926
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Report of a case with re-mitral valve replacement for Björk-Shiley Delrin disc valve prosthesis--disc wear of the Delrin disc 20 years after implantation].
    Abe M; Sakai A; Lin ZB; Hanayama N; Oosawa M
    Nihon Kyobu Geka Gakkai Zasshi; 1996 Apr; 44(4):545-7. PubMed ID: 8666877
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Minor strut fracture of the Björk-Shiley mitral valve].
    Sugita T; Yasuda R; Watarida S; Onoe M; Tabata R; Mori A
    Nihon Kyobu Geka Gakkai Zasshi; 1990 Jun; 38(6):1049-52. PubMed ID: 2204665
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [A case of minor strut fracture of Björk-Shiley Convexo-concave valve and a case of elective prophylactic reoperation].
    Saito S; Tokunaga H; Takahashi S; Aomi S
    Nihon Kyobu Geka Gakkai Zasshi; 1995 Jun; 43(6):852-6. PubMed ID: 7616033
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fracture and embolization of a Björk-Shiley disc. Fatal failure of a prosthetic mitral valve.
    Norenberg DD; Evans RW; Gundersen AE; Abellera RM
    J Thorac Cardiovasc Surg; 1977 Dec; 74(6):925-7. PubMed ID: 303729
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Emergency surgery for thrombosed Björk-Shiley mitral valve prosthesis].
    Shigenobu M; Arai S; Aoki A; Hosotani A; Uchida H; Senoo Y; Teramoto S
    Rinsho Kyobu Geka; 1989 Oct; 9(5):487-9. PubMed ID: 9301961
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sound spectral analysis of prosthetic valvular clicks for diagnosis of thrombosed Björk-Shiley tilting standard disc valve prostheses.
    Sato N; Miura M; Itoh T; Ohmi M; Haneda K; Mohri H; Nitta S; Tanaka M
    J Thorac Cardiovasc Surg; 1993 Feb; 105(2):313-20. PubMed ID: 8429660
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Long-term results over 20 years of aortic valve replacement with the standard Björk-Shiley prosthesis].
    Valla J; Langanay T; Corbineau H; Sevray B; Chaperon J; Menestret P; Lelong B; Leguerrier A; Rioux C; Logeais Y
    Arch Mal Coeur Vaiss; 1996 Sep; 89(9):1137-43. PubMed ID: 8952837
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Bj"ork-Shiley heart vales at the Bern University Hospital. Long-term follow-up of 12 to 23 years after mitral and aortic valve replacement in 503 patients].
    Stuber T; Kaufmann U; Kipfer B; Meier B
    Praxis (Bern 1994); 1999 Feb; 88(9):355-63. PubMed ID: 10191683
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A long-term evaluation of a Björk-Shiley valve prosthesis--eighteen year follow-up].
    Kawashima Y; Nakano S; Kawamoto T
    Rinsho Kyobu Geka; 1989 Aug; 9(4):335-8. PubMed ID: 9301937
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Embolization of the disk in a Björk-Shiley mitral prosthesis: echocardiographic findings with a bidimensional technic].
    García del Castillo H; Candell Riera J; Larrouse Pérez E; Murtra Ferré M; Soler Soler J
    Rev Esp Cardiol; 1987; 40(4):288-9. PubMed ID: 3310147
    [No Abstract]   [Full Text] [Related]  

  • 15. [Intermittent stuck valve of a Björk-Shiley prosthetic valve in mitral position report of a case with successful repair].
    Seo K; Osawa M; Matsuyama T; Kawai A
    Rinsho Kyobu Geka; 1988 Aug; 8(4):395-7. PubMed ID: 9301860
    [No Abstract]   [Full Text] [Related]  

  • 16. [Sudden and fatal malfunction of a Björk-Shiley prosthesis in mitral position due to rupture of the ventricular bracket and disk embolization].
    Casarotto D; Motta A; Fabbri A; Pugliese P; Muneretto C; Zanini M; Sheiban I
    G Ital Cardiol; 1985 Apr; 15(4):451-3. PubMed ID: 4043647
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Fatal rupture of the ventricular strut of a Björk-Shiley prosthesis in mitral position. Description of a case, review of the literature and elements of differential diagnosis].
    Bortolini F; Rodella P; Cerqui F; Bellet C
    G Ital Cardiol; 1987 Aug; 17(8):718-21. PubMed ID: 3319756
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acute postoperative block of mechanical prostheses: incidence and treatment.
    Santé P; Renzulli A; Festa M; Vitale N; Mollo A; Dialetto G; De Luca L
    Cardiovasc Surg; 1994 Jun; 2(3):403-6. PubMed ID: 8049985
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Successful emergency surgery in a material break in a Bjørk-Shiley mitral valve prosthesis].
    Maas AH; van Swieten HA; Knaepen PJ; Defauw JJ; Brutel de la Rivière A; van Herpen G
    Ned Tijdschr Geneeskd; 1986 May; 130(18):835-8. PubMed ID: 3713895
    [No Abstract]   [Full Text] [Related]  

  • 20. A comparative study in patients with Omnicarbon and Björk-Shiley heart valve replacement.
    Otaki M
    Int Surg; 1993; 78(4):338-42. PubMed ID: 8175264
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.