These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

80 related articles for article (PubMed ID: 8000611)

  • 1. Hydrodynamic performance of Carbomedics valves in double valve replacement.
    StrĂ¼ber M; Campbell A; Richard G; Borst HG; Laas J
    J Heart Valve Dis; 1994 Nov; 3(6):667-72. PubMed ID: 8000611
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hydrodynamic function of tilting disc prostheses and bileaflet valves in double valve replacement.
    StrĂ¼ber M; Campbell A; Richard G; Laas J
    Eur J Cardiothorac Surg; 1996; 10(6):422-7. PubMed ID: 8817137
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative hydrodynamic evaluation of bioprosthetic heart valves.
    Marquez S; Hon RT; Yoganathan AP
    J Heart Valve Dis; 2001 Nov; 10(6):802-11. PubMed ID: 11767190
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of various mechanical heart values in the mitral and aortic positions.
    Iwahashi K; Ota T; Okada M; Tsukube T; Matsuda H
    Kobe J Med Sci; 1993 Jun; 39(3):81-93. PubMed ID: 8255076
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fluid dynamics of the CarboMedics kinetic bileaflet prosthetic heart valve.
    Baldwin JT; Campbell A; Luck C; Ogilvie W; Sauter J
    Eur J Cardiothorac Surg; 1997 Feb; 11(2):287-92. PubMed ID: 9080157
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves.
    Reul H; van Son JA; Steinseifer U; Schmitz B; Schmidt A; Schmitz C; Rau G
    J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Small aortic annulus: the hydrodynamic performances of 5 commercially available tissue valves.
    Gerosa G; Tarzia V; Rizzoli G; Bottio T
    J Thorac Cardiovasc Surg; 2006 May; 131(5):1058-64. PubMed ID: 16678590
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Experimental principles for preserving annulo-ventricular integrity of the mitral valve].
    Gams E; Schad H; Heimisch W
    Herz; 1996 Jun; 21(3):144-58. PubMed ID: 8767857
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aortic and mitral valve surgery on the beating heart is lowering cardiopulmonary bypass and aortic cross clamp time.
    Gersak B; Sutlic Z
    Heart Surg Forum; 2002; 5(2):182-6. PubMed ID: 12125670
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Favorable results in patients with small size CarboMedics heart valves in the aortic position.
    Imanaka K; Takamoto S; Furuse A
    Ann Thorac Cardiovasc Surg; 2001 Jun; 7(3):150-4. PubMed ID: 11481020
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Harvested porcine mitral xenograft fixation: impact on fluid dynamic performance.
    Jensen MO; Lemmon JD; Gessaghi VC; Conrad CP; Levine RA; Yoganathan AP
    J Heart Valve Dis; 2001 Jan; 10(1):111-24. PubMed ID: 11206757
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves.
    Bottio T; Caprili L; Casarotto D; Gerosa G
    J Thorac Cardiovasc Surg; 2004 Sep; 128(3):457-62. PubMed ID: 15354108
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Total energy loss in prosthetic valves.
    Fisher J
    J Heart Valve Dis; 1994 Nov; 3(6):666. PubMed ID: 8000610
    [No Abstract]   [Full Text] [Related]  

  • 14. Twenty-year comparison of tissue and mechanical valve replacement.
    Khan SS; Trento A; DeRobertis M; Kass RM; Sandhu M; Czer LS; Blanche C; Raissi S; Fontana GP; Cheng W; Chaux A; Matloff JM
    J Thorac Cardiovasc Surg; 2001 Aug; 122(2):257-69. PubMed ID: 11479498
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of the Chitra tilting disc heart valve prosthesis.
    Bhuvaneshwar GS; Muraleedharan CV; Vijayan GA; Kumar RS; Valiathan MS
    J Heart Valve Dis; 1996 Jul; 5(4):448-58. PubMed ID: 8858513
    [TBL] [Abstract][Full Text] [Related]  

  • 16. New flexible polymeric heart valve prostheses for the mitral and aortic positions.
    Daebritz SH; Fausten B; Hermanns B; Franke A; Schroeder J; Groetzner J; Autschbach R; Messmer BJ; Sachweh JS
    Heart Surg Forum; 2004; 7(5):E525-32. PubMed ID: 15799940
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative study of the hydrodynamic function of the size 19mm and 21mm St. Jude Medical Hemodynamic Plus Bileaflet Heart valves.
    Fisher J
    J Heart Valve Dis; 1994 Jan; 3(1):75-80. PubMed ID: 8162222
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemodynamics of the mitral valve under edge-to-edge repair: an in vitro steady flow study.
    Shi L; He Z
    J Biomech Eng; 2009 May; 131(5):051010. PubMed ID: 19388780
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Usefulness of magnetic resonance imaging for managing patients with prosthetic carbon valve in the mitral position].
    Koito H; Imai Y; Suzuki J; Ohkubo N; Nakamura C; Takahashi H; Iwasaka T; Inada M
    J Cardiol; 1997 Nov; 30(5):251-63. PubMed ID: 9395956
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.
    Shu MC; Gross JM; O'Rourke KK; Yoganathan AP
    J Heart Valve Dis; 2003 Jul; 12(4):503-12. PubMed ID: 12918854
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.