These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 8002241)

  • 1. Computational principles in Purkinje I and IV reflection pattern evaluation for the assessment of ocular alignment.
    Barry JC; Effert R; Reim M; Meyer-Ebrecht D
    Invest Ophthalmol Vis Sci; 1994 Dec; 35(13):4205-18. PubMed ID: 8002241
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of ocular alignment with photographic Purkinje I and IV reflection pattern evaluation.
    Barry JC; Effert R; Kaupp A; Burhoff A
    Invest Ophthalmol Vis Sci; 1994 Dec; 35(13):4219-35. PubMed ID: 8002242
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Detection and diagnosis of small ocular misalignment with the Purkinje reflex pattern method].
    Barry JC; Effert R; Hoffmann N
    Klin Monbl Augenheilkd; 1996 Mar; 208(3):167-80. PubMed ID: 8699775
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Self-assessment of angles of strabismus with photographic Purkinje I and IV reflection pattern evaluation.
    Effert R; Barry JC; Colberg R; Kaupp A; Scherer G
    Graefes Arch Clin Exp Ophthalmol; 1995 Aug; 233(8):494-506. PubMed ID: 8537025
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Computer-assisted measurement of ocular misalignment in infants and young children using the digital Purkinje reflection pattern procedure].
    Barry JC; Effert R; Kaupp A; Kleine M; Reim M
    Ophthalmologe; 1994 Feb; 91(1):51-61. PubMed ID: 8173252
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An automated Hirschberg test for infants.
    Model D; Eizenman M
    IEEE Trans Biomed Eng; 2011 Jan; 58(1):103-9. PubMed ID: 20934943
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Videographic Hirschberg measurement of simulated strabismic deviations.
    Miller JM; Mellinger M; Greivenkemp J; Simons K
    Invest Ophthalmol Vis Sci; 1993 Oct; 34(11):3220-9. PubMed ID: 8407230
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of binocular alignment in normal monkeys and in monkeys with strabismus.
    Quick MW; Boothe RG
    Invest Ophthalmol Vis Sci; 1989 Jun; 30(6):1159-68. PubMed ID: 2732030
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improving the accuracy and reliability of remote system-calibration-free eye-gaze tracking.
    Hennessey CA; Lawrence PD
    IEEE Trans Biomed Eng; 2009 Jul; 56(7):1891-900. PubMed ID: 19272975
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improved computing scheme for measuring eye alignment with Purkinje images I and IV.
    Barry JC; Backes A; Pongs UM; Kirschkamp T; Dunne MC
    Ophthalmic Physiol Opt; 1997 Sep; 17(5):433-40. PubMed ID: 9390370
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accurate gaze direction measurements with free head movement for strabismus angle estimation.
    Bakker NM; Lenseigne BA; Schutte S; Geukers EB; Jonker PP; van der Helm FC; Simonsz HJ
    IEEE Trans Biomed Eng; 2013 Nov; 60(11):3028-35. PubMed ID: 23399951
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Measuring the effect of eyeglasses on determination of squint angle with Purkinje reflexes and the prism cover test].
    Barry JC; Backes A
    Klin Monbl Augenheilkd; 1998 Apr; 212(4):234-9. PubMed ID: 9644670
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Screening for childhood strabismus by primary care physicians.
    Weinstock VM; Weinstock DJ; Kraft SP
    Can Fam Physician; 1998 Feb; 44():337-43. PubMed ID: 9512837
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantification of the Brückner test for strabismus.
    Miller JM; Hall HL; Greivenkamp JE; Guyton DL
    Invest Ophthalmol Vis Sci; 1995 Apr; 36(5):897-905. PubMed ID: 7706038
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [A diploptic method in the early treatment of concomitant strabismus in children].
    Kascenko TP; Tarascowa MM
    Klin Oczna; 1989 Jun; 91(6):176. PubMed ID: 2632983
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Binocular lens tilt and decentration measurements in healthy subjects with phakic eyes.
    Schaeffel F
    Invest Ophthalmol Vis Sci; 2008 May; 49(5):2216-22. PubMed ID: 18436854
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Interocular transfer of the movement aftereffect in central and peripheral vision of people with strabismus.
    O'Shea RP; McDonald AA; Cumming A; Peart D; Sanderson G; Molteno AC
    Invest Ophthalmol Vis Sci; 1994 Jan; 35(1):313-7. PubMed ID: 8300359
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The diagnosis of amblyopia and strabismus: a programmed approach.
    Franzblau SC
    J Am Optom Assoc; 1977 Oct; 48(10):1248-57. PubMed ID: 908826
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Limbus versus pupil center for ocular alignment measurement with corneal reflexes.
    Barry JC; Backes A
    Invest Ophthalmol Vis Sci; 1997 Nov; 38(12):2597-607. PubMed ID: 9375579
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Video vision development assessment in diagnosis and documentation of microtropia.
    Cibis GW
    Binocul Vis Strabismus Q; 2005; 20(3):151-8. PubMed ID: 16359277
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.