These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 8007770)

  • 21. Diagnosis of renal artery stenosis: feasibility of combining MR angiography, MR renography, and gadopentetate-based measurements of glomerular filtration rate.
    Ros PR; Gauger J; Stoupis C; Burton SS; Mao J; Wilcox C; Rosenberg EB; Briggs RW
    AJR Am J Roentgenol; 1995 Dec; 165(6):1447-51. PubMed ID: 7484583
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Differential renal function estimation by dynamic renal scintigraphy: influence of background definition and radiopharmaceutical.
    Caglar M; Gedik GK; Karabulut E
    Nucl Med Commun; 2008 Nov; 29(11):1002-5. PubMed ID: 18836380
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of renal function with 99mTc-MAG3 using semiautomated regions of interest.
    Inoue Y; Yoshikawa K; Yoshioka N; Watanabe T; Saegusa S; Kaneko Y; Yokoyama I; Ohtomo K
    J Nucl Med; 2000 Dec; 41(12):1947-54. PubMed ID: 11138677
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Clinical assessment of 99mTc-MAG3 scintigraphy for impaired renal function].
    Sato M; Hirayama K; Ishikawa N; Takeda T; Wu J; Itai Y; Kobayashi M; Koyama A
    Kaku Igaku; 1994 Jan; 31(1):75-84. PubMed ID: 8309113
    [TBL] [Abstract][Full Text] [Related]  

  • 25. MAG3-F0 scintigraphy in decision making for emergency intervention in renal colic after helical CT positive for a urolith.
    Sfakianakis GN; Cohen DJ; Braunstein RH; Leveillee RJ; Lerner I; Bird VG; Sfakianakis E; Georgiou MF; Block NL; Lynne CM
    J Nucl Med; 2000 Nov; 41(11):1813-22. PubMed ID: 11079488
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Evaluation of 99mTc-MAG3 (mercaptoacetyltriglycine) renography for pediatric patients].
    Tabuchi K; Adachi I; Doi K; Hou N; Komori T; Nakata Y; Matsui R; Sueyoshi K; Narabayashi I
    Kaku Igaku; 1999 Jan; 36(1):15-22. PubMed ID: 10087761
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Transplant renography: 99m-Tc-DTPA versus 99m-Tc-MAG3. A preliminary note.
    Fraile M; Castell J; Buxeda M; Cuartero A; Cantarell C; Domenech-Torné FM
    Eur J Nucl Med; 1989; 15(12):776-9. PubMed ID: 2533892
    [TBL] [Abstract][Full Text] [Related]  

  • 28. 99mTc-MAG3 renography: normal values for MAG3 clearance and curve parameters, excretory parameters, and residual urine volume.
    Esteves FP; Taylor A; Manatunga A; Folks RD; Krishnan M; Garcia EV
    AJR Am J Roentgenol; 2006 Dec; 187(6):W610-7. PubMed ID: 17114514
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [A phase 2 clinical study of 99mTc-MAG3 injectable a dynamic renal imaging agent--evaluation of its safety, effectiveness and optimal dose].
    Torizuka K; Ishibashi A; Ikekubo K; Yamamoto K; Nishibuchi S
    Kaku Igaku; 1993 Nov; 30(11):1379-92. PubMed ID: 8277600
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Optimization of saturation-recovery dynamic contrast-enhanced MRI acquisition protocol: monte carlo simulation approach demonstrated with gadolinium MR renography.
    Zhang JL; Conlin CC; Carlston K; Xie L; Kim D; Morrell G; Morton K; Lee VS
    NMR Biomed; 2016 Jul; 29(7):969-77. PubMed ID: 27200499
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of Tc-99m DTPA and Tc-99m MAG3 perfusion time-activity curves in patients with renal allograft dysfunction.
    Aktaş A; Aras M; Colak T; Gençoğlu A; Karakayali H
    Transplant Proc; 2006 Mar; 38(2):449-53. PubMed ID: 16549144
    [TBL] [Abstract][Full Text] [Related]  

  • 32. MR renography using a dynamic gradient-echo sequence and low-dose gadopentetate dimeglumine as an alternative to radionuclide renography.
    Teh HS; Ang ES; Wong WC; Tan SB; Tan AG; Chng SM; Lin MB; Goh JS
    AJR Am J Roentgenol; 2003 Aug; 181(2):441-50. PubMed ID: 12876024
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Detection of renal ischemic lesions using Gd-DTPA enhanced turbo FLASH MRI: experimental and clinical results.
    Vosshenrich R; Kallerhoff M; Gröne HJ; Fischer U; Funke M; Kopka L; Siebert G; Ringert RH; Grabbe E
    J Comput Assist Tomogr; 1996; 20(2):236-43. PubMed ID: 8606230
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Residual kidney function after donor nephrectomy. Assessment by 99mTc-MAG3-clearance.
    Hamscho N; Wilhelm A; Döbert N; Menzel C; Gossmann J; Berner U; Zaplatnikov K; Scheuermann EH; Grünwald F
    Nuklearmedizin; 2005; 44(5):200-4. PubMed ID: 16395496
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Administered activity optimization in 99mTc-MAG3 renography for adults.
    Díaz MP; Aparicio EE; Rizo OD; Díaz RR; Rodríguez CH
    J Nucl Med Technol; 2003 Dec; 31(4):216-21. PubMed ID: 14657288
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Significance of early tubular extraction in the first minute of Tc-99m MAG3 renal transplant scintigraphy.
    Lin E; Alavi A
    Clin Nucl Med; 1998 Apr; 23(4):217-22. PubMed ID: 9554192
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A renal protocol for all ages and all indications: mercapto-acetyl-triglycine (MAG3) with simultaneous injection of furosemide (MAG3-F0): a 17-year experience.
    Sfakianakis GN; Sfakianaki E; Georgiou M; Serafini A; Ezuddin S; Kuker R; Zilleruelo G; Strauss J; Abitbol C; Chandar J; Seeherunvong W; Bourgoignie J; Roth D; Leveillee R; Bird VG; Block N; Gosalbez R; Labbie A; Guerra JJ; Yrizarry J
    Semin Nucl Med; 2009 May; 39(3):156-73. PubMed ID: 19341836
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Usefulness of renal dynamic function study with 99mTc-MAG3 (mercaptoacetylglycylglycylglycine)].
    Shirakawa S; Tamaki N; Torizuka T; Fujita T; Yano S; Tsuchimochi S; Yonekura Y; Konishi J; Terai A
    Kaku Igaku; 1994 Aug; 31(8):977-83. PubMed ID: 7933686
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of renal function after laparoscopic partial nephrectomy with renal scintigraphy using 99mtechnetium-mercaptoacetyltriglycine.
    Kobayashi Y; Usui Y; Shima M; Akio H; Miyakita H; Inatsuchi H; Terachi T
    Int J Urol; 2006 Nov; 13(11):1371-4. PubMed ID: 17083385
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Background correction in estimating initial renal uptake. Comparison between Tc-99m MAG3 and Tc-99m DTPA.
    Inoue Y; Machida K; Honda N; Takahashi T; Mamiya T
    Clin Nucl Med; 1994 Dec; 19(12):1049-54. PubMed ID: 7874800
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.