These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 8012260)

  • 1. A comparison of modified Knowles pins and cannulated cancellous screws for the treatment of nondisplaced or impacted femoral neck fractures.
    Jarolem KL; Koval KJ; Zuckerman JD; Aharonoff G
    Bull Hosp Jt Dis; 1993; 53(3):11-4. PubMed ID: 8012260
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Internal fixation of femoral neck fractures. A comparative biomechanical study of Knowles pins and 6.5-mm cancellous screws.
    Springer ER; Lachiewicz PF; Gilbert JA
    Clin Orthop Relat Res; 1991 Jun; (267):85-92. PubMed ID: 2044298
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Treatment of femoral neck fractures with a sliding compression screw and two Knowles pins.
    Ort PJ; LaMont J
    Clin Orthop Relat Res; 1984 Nov; (190):158-62. PubMed ID: 6488626
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cannulated screws for fixation of femoral neck fractures. No difference between Uppsala screws and Richards screws in a randomized prospective study of 268 cases.
    Lagerby M; Asplund S; Ringqvist I
    Acta Orthop Scand; 1998 Aug; 69(4):387-91. PubMed ID: 9798447
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Crossed pins vs parallel pins in the treatment of femoral neck fractures.
    Gebuhr P; Hovgaard C; Petersen JR
    Orthopedics; 1991 Aug; 14(8):908-9. PubMed ID: 1923973
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Covered osteosynthesis through cannulated screws in medial Garden type I and II femoral neck fractures].
    Rzesacz EH; Weinberg AM; Reilmann H
    Unfallchirurg; 1995 Sep; 98(9):478-82. PubMed ID: 7481833
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fixation of femoral neck fracture. Prospective comparison of von Bahr screws, Gouffon screws, and Hessel pins.
    Lindequist S; Malmqvist B; Ullmark G
    Acta Orthop Scand; 1989 Jun; 60(3):293-8. PubMed ID: 2750502
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In situ fixation of nondisplaced intracapsular fractures of the proximal femur.
    Rodríguez-Merchán EC
    Clin Orthop Relat Res; 2002 Jun; (399):42-51. PubMed ID: 12011693
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanics of pin and screw fixation of femoral neck fractures.
    Holmes CA; Edwards WT; Myers ER; Lewallen DG; White AA; Hayes WC
    J Orthop Trauma; 1993; 7(3):242-7. PubMed ID: 8326429
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Breakage of Knowles pins used for femoral neck fractures.
    Lozano Requena JA; Bas Hermida T; Perez Belmonte C; Llabres AJ; Baixauli F
    Int Orthop; 1993 Dec; 17(6):365-6. PubMed ID: 8163311
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three cancellous bone screws versus a screw-angle plate in the treatment of Garden I and II fractures of the femoral neck.
    Kuokkanen H; Korkala O; Antti-Poika I; Tolonen J; Lehtimäki MY; Silvennoinen T
    Acta Orthop Belg; 1991; 57(1):53-7. PubMed ID: 2038944
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A biomechanical study of two methods of internal fixation of unstable fractures of the femoral neck. A preliminary study.
    Goodman SB; Davidson JA; Locke L; Novotny S; Jones H; Csongradi JJ
    J Orthop Trauma; 1992; 6(1):66-72. PubMed ID: 1556626
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Can we predict failure of percutaneous fixation of femoral neck fractures?
    Kane C; Jo J; Siegel J; Matuszewski PE; Swart E
    Injury; 2020 Feb; 51(2):357-360. PubMed ID: 31679832
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Uppsala screws or Hansson pins for internal fixation of femoral neck fractures? A prospective study of 180 cases.
    Herngren B; Mörk-Petersen F; Bauer M
    Acta Orthop Scand; 1992 Feb; 63(1):41-6. PubMed ID: 1738969
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Internal fixation of femoral neck fractures. A follow-up study of 118 cases.
    Stappaerts KH; Broos PL
    Acta Chir Belg; 1987; 87(4):247-51. PubMed ID: 3661004
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Fixation of fractures of the femoral neck using screws or hook-pins. Radionuclide study and short-term results].
    Stromquist B; Ross H; Hansson LI; Ohlin P
    Rev Chir Orthop Reparatrice Appar Mot; 1988; 74(7):609-13. PubMed ID: 3241891
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In the treatment of medial fractures of the neck of the femur. Osteosynthesis with modified Knowles pins.
    Pitto E; Giusti E; Santini A
    Acta Orthop Belg; 1980; 46(2):117-29. PubMed ID: 7457107
    [No Abstract]   [Full Text] [Related]  

  • 18. Verified causes of failure in the treatment of femoral neck fractures with multiple Knowles pins.
    Di Muria GV; Marcucci M; Pitto RP; Troiani M
    Ital J Orthop Traumatol; 1991 Mar; 17(1):107-16. PubMed ID: 1894506
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prospective randomized controlled trial comparing dynamic hip screw and screw fixation for undisplaced subcapital hip fractures.
    Watson A; Zhang Y; Beattie S; Page RS
    ANZ J Surg; 2013 Sep; 83(9):679-83. PubMed ID: 22998439
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fixation of displaced femoral neck fractures with a sliding screw plate and a cancellous screw or two Olmed screws. A prospective, randomized study of 225 elderly patients with a 3-year follow-up.
    Benterud JG; Husby T; Nordsletten L; Alho A
    Ann Chir Gynaecol; 1997; 86(4):338-42. PubMed ID: 9474428
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.