137 related articles for article (PubMed ID: 8026439)
1. Capillary electrophoresis combined with 252Cf plasma desorption and electrospray mass spectrometry for the structural characterization of hydrophobic polypeptides using organic solvents.
Weinmann W; Parker CE; Baumeister K; Maier C; Tomer KB; Przybylski M
Electrophoresis; 1994 Feb; 15(2):228-33. PubMed ID: 8026439
[TBL] [Abstract][Full Text] [Related]
2. Structural characterization of polypeptides and proteins by combination of capillary electrophoresis and (252)Cf plasma desorption mass spectrometry.
Weinmann W; Baumeister K; Kaufmann I; Przybylski M
J Chromatogr; 1993 Jan; 628(1):111-21. PubMed ID: 8429073
[TBL] [Abstract][Full Text] [Related]
3. Isolation of hydrophobic lipoproteins in organic solvents by pressure-assisted capillary electrophoresis for subsequent mass spectrometric characterization.
Weinmann W; Maier C; Baumeister K; Przybylski M; Parker CE; Tomer KB
J Chromatogr A; 1994 Apr; 664(2):271-5. PubMed ID: 8199708
[TBL] [Abstract][Full Text] [Related]
4. Capillary electrophoresis-atmospheric pressure ionization mass spectrometry for the characterization of peptides. Instrumental considerations for mass spectrometric detection.
Johansson IM; Huang EC; Henion JD; Zweigenbaum J
J Chromatogr; 1991 Aug; 554(1-2):311-27. PubMed ID: 1795040
[TBL] [Abstract][Full Text] [Related]
5. N-terminal sequence determination of polypeptides and peptide mixtures by Edman degradation combined with californium-252 plasma desorption mass spectrometry.
Nielsen PF; Landis B; Svoboda M; Schneider K; Przybylski M
Anal Biochem; 1990 Dec; 191(2):302-8. PubMed ID: 2085176
[TBL] [Abstract][Full Text] [Related]
6. Cetyltrimethylammonium chloride as a surfactant buffer additive for reversed-polarity capillary electrophoresis-electrospray mass spectrometry.
Varghese J; Cole RB
J Chromatogr A; 1993 Oct; 652(2):369-76. PubMed ID: 8287131
[TBL] [Abstract][Full Text] [Related]
7. Determination of amino acids by on-line capillary electrophoresis-electrospray ionization mass spectrometry.
Lu W; Yang G; Cole RB
Electrophoresis; 1995 Apr; 16(4):487-92. PubMed ID: 7588515
[TBL] [Abstract][Full Text] [Related]
8. Pressure-assisted and pressure-programmed capillary electrophoresis/electrospray ionization time of flight-mass spectrometry for the analysis of peptide mixtures.
Cao P; Moini M
Electrophoresis; 1998 Sep; 19(12):2200-6. PubMed ID: 9761204
[TBL] [Abstract][Full Text] [Related]
9. Capillary electrophoresis-mass spectrometry using robust poly(ether ether ketone) capillary for tolerance to high content of organic solvents.
Zhou W; Liu Y; Liao X; Chen Z
J Chromatogr A; 2019 May; 1593():156-163. PubMed ID: 30718059
[TBL] [Abstract][Full Text] [Related]
10. [An improved method of preparing protein and peptide probes in mass spectrometry with ionization of division fragments by californium-252 (TOF-PDMS)].
Chivanov VD; Zubarev RA; Aksenov SA; Bordunova OG; Eremenko VI; Kabanets VM; Tatarinova VI; Mishnev AK; Kuraev VV; Knysh AN; Eremenko IA
Bioorg Khim; 1996 Aug; 22(8):585-8. PubMed ID: 8985001
[TBL] [Abstract][Full Text] [Related]
11. The use of plasma desorption time-of-flight mass spectrometry to screen for products of prohormone processing in crude tissue extracts.
Andrews PC; Alai M; Cotter RJ
Anal Biochem; 1988 Oct; 174(1):23-31. PubMed ID: 3064650
[TBL] [Abstract][Full Text] [Related]
12. Characterization of a synthetic 37-residue fragment of a monoclonal antibody against herpes virus by capillary electrophoresis/electrospray (ionspray) mass spectrometry and 252Cf plasma desorption mass spectrometry.
Kostiainen R; Lasonder E; Bloemhoff W; van Veelen PA; Welling GW; Bruins AP
Biol Mass Spectrom; 1994 Jun; 23(6):346-52. PubMed ID: 8038227
[TBL] [Abstract][Full Text] [Related]
13. Impact of organic solvents on the resolution of synthetic peptides by capillary electrophoresis.
Yang Y; Boysen RI; Hearn MT
J Chromatogr A; 2004 Jul; 1043(1):81-9. PubMed ID: 15317416
[TBL] [Abstract][Full Text] [Related]
14. Integration of microfabricated devices to capillary electrophoresis-electrospray mass spectrometry using a low dead volume connection: application to rapid analyses of proteolytic digests.
Li J; Thibault P; Bings NH; Skinner CD; Wang C; Colyer C; Harrison J
Anal Chem; 1999 Aug; 71(15):3036-45. PubMed ID: 10450153
[TBL] [Abstract][Full Text] [Related]
15. High-efficiency peptide analysis on monolithic multimode capillary columns: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry.
Ivanov AR; Horváth C; Karger BL
Electrophoresis; 2003 Nov; 24(21):3663-73. PubMed ID: 14613191
[TBL] [Abstract][Full Text] [Related]
16. Determination of carnitine and acylcarnitines in biological samples by capillary electrophoresis-mass spectrometry.
Heinig K; Henion J
J Chromatogr B Biomed Sci Appl; 1999 Dec; 735(2):171-88. PubMed ID: 10670733
[TBL] [Abstract][Full Text] [Related]
17. Open-tubular capillary electrochromatography coupled with electrospray ionization mass spectrometry for peptide analysis.
Yang Y; Boysen RI; Matyska MT; Pesek JJ; Hearn MT
Anal Chem; 2007 Jul; 79(13):4942-9. PubMed ID: 17539599
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of volatile eluents and electrolytes for high-performance liquid chromatography-electrospray ionization mass spectrometry and capillary electrophoresis-electrospray ionization mass spectrometry of proteins. II. Capillary electrophoresis.
Huber CG; Premstaller A; Kleindienst G
J Chromatogr A; 1999 Jul; 849(1):175-89. PubMed ID: 10444842
[TBL] [Abstract][Full Text] [Related]
19. Analysis of tamoxifen and its metabolites by on-line capillary electrophoresis-electrospray ionization mass spectrometry employing nonaqueous media containing surfactants.
Lu W; Poon GK; Carmichael PL; Cole RB
Anal Chem; 1996 Feb; 68(4):668-74. PubMed ID: 8999741
[TBL] [Abstract][Full Text] [Related]
20. Californium-252 plasma desorption mass spectroscopy.
Macfarlane RD; Torgerson DF
Science; 1976 Mar; 191(4230):920-5. PubMed ID: 1251202
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]