These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

87 related articles for article (PubMed ID: 8027142)

  • 41. Effect of locking mechanism on fluid and particle flow through modular acetabular components.
    Khalily C; Tanner MG; Williams VG; Whiteside LA
    J Arthroplasty; 1998 Apr; 13(3):254-8. PubMed ID: 9590635
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Histologic, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty.
    Dorr LD; Bloebaum R; Emmanual J; Meldrum R
    Clin Orthop Relat Res; 1990 Dec; (261):82-95. PubMed ID: 2173987
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Analysis of particles in acetabular components from patients with osteolysis.
    Bloebaum RD; Zou L; Bachus KN; Shea KG; Hofmann AA; Dunn HK
    Clin Orthop Relat Res; 1997 May; (338):109-18. PubMed ID: 9170371
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Metal debris from titanium spinal implants.
    Wang JC; Yu WD; Sandhu HS; Betts F; Bhuta S; Delamarter RB
    Spine (Phila Pa 1976); 1999 May; 24(9):899-903. PubMed ID: 10327512
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Simulation of initial frontside and backside wear rates in a modular acetabular component with multiple screw holes.
    Kurtz SM; Ochoa JA; Hovey CB; White CV
    J Biomech; 1999 Sep; 32(9):967-76. PubMed ID: 10460134
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Size of metallic and polyethylene debris particles in failed cemented total hip replacements.
    Lee JM; Salvati EA; Betts F; DiCarlo EF; Doty SB; Bullough PG
    J Bone Joint Surg Br; 1992 May; 74(3):380-4. PubMed ID: 1587882
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Back-side wear in HexLoc cups clinico-radiological, immunohistopathological, finite element, and retrieval analysis studies.
    Kawaji H; Koistinen A; Korhonen R; Lappalainen R; Lohman M; Soininen A; Gomez Barrena E; Konttinen YT; Ylinen P; Tallroth K
    J Long Term Eff Med Implants; 2014; 24(4):319-31. PubMed ID: 25747033
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A quantitative study of the tissue reaction and its relationship to debris production from a joint implant.
    Ferris BD
    J Exp Pathol (Oxford); 1990 Jun; 71(3):367-73. PubMed ID: 2372413
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The role of backside polishing, cup angle, and polyethylene thickness on the contact stresses in metal-backed acetabular components.
    Kurtz SM; Edidin AA; Bartel DL
    J Biomech; 1997 Jun; 30(6):639-42. PubMed ID: 9165399
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Polyethylene debris in lymph nodes after a total hip arthroplasty. A report of two cases.
    Morawski DR; Coutts RD; Handal EG; Luibel FJ; Santore RF; Ricci JL
    J Bone Joint Surg Am; 1995 May; 77(5):772-6. PubMed ID: 7744903
    [No Abstract]   [Full Text] [Related]  

  • 51. Water-based lubricant as an adjunct to wound toilet: Validation of a technique by experiment.
    Rehman H; Rankin I; Ferguson K; Jones B; Frame M
    Injury; 2016 Aug; 47(8):1798-800. PubMed ID: 27282686
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Polyethylene debris in lymph nodes.
    Péoc'h M; Pasquier D; Pasquier B
    J Bone Joint Surg Am; 1996 Nov; 78(11):1784. PubMed ID: 8934496
    [No Abstract]   [Full Text] [Related]  

  • 53. Particles in loose hips.
    Campbell P; Kossovsky N; Schmalzried TP
    J Bone Joint Surg Br; 1993 Jan; 75(1):161-2. PubMed ID: 8421019
    [No Abstract]   [Full Text] [Related]  

  • 54. Monobloc press-fit cups with large-diameter bearings are safe in revision total hip arthroplasty.
    Synnott PA; Sivaloganathan S; Kiss MO; Binette B; Morcos MW; Vendittoli PA
    Orthop Rev (Pavia); 2022; 14(4):38926. PubMed ID: 36349354
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Primary Stability in Hip Revision Arthroplasty: Comparison of the Stability of Cementless Fixed Augments on a Modular Acetabular Cage System with and without Cranial Straps.
    Jaenisch M; Kohlhof H; Wirtz DC; Schildberg FA; Beckmann NA; Kretzer JP; Schonhoff M; Jäger S
    J Clin Med; 2021 Sep; 10(17):. PubMed ID: 34501450
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The role of fretting-frequency on the damage modes of THR modular junction: In-vitro study.
    Radzik B; Bijukumar D; Cheng KY; Badhe RV; Barba M; Mathew MT
    Mater Sci Eng C Mater Biol Appl; 2021 Jul; 126():112128. PubMed ID: 34082945
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Additively manufactured calcium phosphate reinforced CoCrMo alloy: Bio-tribological and biocompatibility evaluation for load-bearing implants.
    Bandyopadhyay A; Shivaram A; Isik M; Avila JD; Dernell WS; Bose S
    Addit Manuf; 2019 Aug; 28():312-324. PubMed ID: 31341790
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Comparison of the stability of three fixation techniques between porous metal acetabular components and augments.
    Beckmann NA; Bitsch RG; Gondan M; Schonhoff M; Jaeger S
    Bone Joint Res; 2018 Apr; 7(4):282-288. PubMed ID: 29922446
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component.
    Takasago T; Goto T; Wada K; Hamada D; Iwame T; Matsuura T; Nagamachi A; Sairyo K
    Case Rep Orthop; 2016; 2016():5301451. PubMed ID: 27648325
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners.
    Bali K; McCalden RW; Naudie DD; MacDonald SJ; Teeter MG
    Clin Orthop Relat Res; 2016 Feb; 474(2):374-82. PubMed ID: 26201422
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.