These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 8033180)

  • 1. Myocardial viability. Assessment by cardiac scintigraphy.
    Gimple LW; Beller GA
    Cardiol Clin; 1994 May; 12(2):317-32. PubMed ID: 8033180
    [TBL] [Abstract][Full Text] [Related]  

  • 2. New applications of myocardial perfusion imaging.
    DePuey EG
    Tex Heart Inst J; 1996; 23(2):122-7. PubMed ID: 8792543
    [No Abstract]   [Full Text] [Related]  

  • 3. Identification of viable myocardium with technetium-99m-MIBI infusion.
    Worsley DF; Fung AY; Jue J; Burns RJ
    J Nucl Med; 1995 Jun; 36(6):1037-9. PubMed ID: 7769424
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fluorine 18-labeled fluorodeoxyglucose myocardial single-photon emission computed tomography: an alternative for determining myocardial viability.
    Sandler MP; Patton JA
    J Nucl Cardiol; 1996; 3(4):342-9. PubMed ID: 8799254
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Delayed recovery of hibernating myocardium after surgical revascularization: implications for discrepancy between metabolic imaging and dobutamine echocardiography for assessment of myocardial viability.
    Bax JJ; Poldermans D; Visser FC; Elhendy A; Boersma E; Cornel JH; Fiorettri PM; Visser CA
    J Nucl Cardiol; 1999; 6(6):685-7. PubMed ID: 10608600
    [No Abstract]   [Full Text] [Related]  

  • 6. Nuclear imaging techniques for the assessment of myocardial viability.
    Jain D; Zaret BL
    Cardiol Clin; 1995 Feb; 13(1):43-57. PubMed ID: 7796431
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Myocardial scintigraphy with Tc-99m-MIBI for assessing the extent and severity of coronary disease: a comparison with thallium-201 and equilibrium angiocardioscintigraphy].
    Leoncini M; Sciagrà R; Bisi G; Santoro GM; Fazzini PF
    G Ital Cardiol; 1993 Feb; 23(2):127-38. PubMed ID: 8491353
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of myocardial perfusion imaging to assess viability.
    Travin MI
    J Nucl Cardiol; 2000; 7(1):72-80. PubMed ID: 10698237
    [No Abstract]   [Full Text] [Related]  

  • 9. Selecting patients with ischemic cardiomyopathy for medical treatment, revascularization, or heart transplantation.
    Beller GA
    J Nucl Cardiol; 1997; 4(2 Pt 2):S152-7. PubMed ID: 9115077
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparable uptake of thallium-201 and technetium-99m MIBI in hibernating and "maimed" myocardium.
    Lipiecki J; Maublant JC; Citron B; Mestas D; Jousse F; Albuisson E; Bourgeois V; Veyre A; Ponsonnaille J
    Am J Cardiol; 1997 Oct; 80(7):940-3. PubMed ID: 9382013
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Potential and limitation of myocardial perfusion scintigraphy for detection of viability].
    Knapp WH
    Nuklearmedizin; 1995 Jun; 34(3):118-26. PubMed ID: 7630745
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rest technetium 99m-sestamibi tomoscintigraphy in hibernating myocardium.
    Maublant JC; Citron B; Lipiecki J; Mestas D; Bailly P; Veyre A; de Riberolles C; Ponsonnaille J
    Am Heart J; 1995 Feb; 129(2):306-14. PubMed ID: 7832104
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Potential and limitations of Tc-99m sestamibi scintigraphy for the diagnosis of myocardial viability.
    Cornel JH; Arnese M; Forster T; Postma-Tjoa J; Reijs AE; Fioretti PM
    Herz; 1994 Feb; 19(1):19-27. PubMed ID: 8150411
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radionuclide techniques for the assessment of myocardial viability.
    Skoufis E; McGhie AI
    Tex Heart Inst J; 1998; 25(4):272-9. PubMed ID: 9885104
    [No Abstract]   [Full Text] [Related]  

  • 15. The assessment of myocardial viability and hibernation using resting thallium imaging.
    Perrone-Filardi P; Chiariello M; Underwood R
    Clin Cardiol; 2000 Oct; 23(10):719-22. PubMed ID: 11061048
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Imaging techniques in the assessment of myocardial hibernation.
    Underwood SR
    Eur J Nucl Med Mol Imaging; 2004 Aug; 31(8):1209; author reply 1210-1. PubMed ID: 15197506
    [No Abstract]   [Full Text] [Related]  

  • 17. Assessment of myocardial viability by radionuclide imaging.
    Giubbini R; Milan E; Terzi A; Pieri P
    Int J Cardiol; 1998 May; 65 Suppl 1():S65-8. PubMed ID: 9706830
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Myocardial perfusion imaging using single-photon emission computed tomography.
    Garvin AA; Cullom SJ; Garcia EV
    Am J Card Imaging; 1994 Apr; 8(2):189-98. PubMed ID: 8032191
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Perfusion scintigraphy of the heart].
    van Vlies B; van Royen EA
    Ned Tijdschr Geneeskd; 1991 Sep; 135(37):1681-6. PubMed ID: 1922510
    [No Abstract]   [Full Text] [Related]  

  • 20. Radionuclide techniques for myocardial viability and hibernation.
    Walton S
    Heart; 1999 Jan; 81(1):6-7. PubMed ID: 10220535
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.