These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 8034878)

  • 21. Multicenter investigation of an implantable cardioverter-defibrillator algorithm to detect oversensing.
    Welte N; Strik M; Eschalier R; Mondoly P; Defaye P; Frontera A; Ritter P; Haïssaguerre M; Ploux S; Koneru J; Ellenbogen KA; Bordachar P
    Heart Rhythm; 2017 Jul; 14(7):1008-1015. PubMed ID: 28323174
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Programmable VT detection enhancements in implantable cardioverter defibrillator therapy.
    Neuzner J; Pitschner HF; Schlepper M
    Pacing Clin Electrophysiol; 1995 Mar; 18(3 Pt 2):539-47. PubMed ID: 7777418
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Diagnostic performance of a dual-chamber cardioverter defibrillator programmed with nominal settings: a European prospective study.
    Sadoul N; Jung W; Jordaens L; Leenhardt A; Santini M; Wolpert C; Aliot E;
    J Cardiovasc Electrophysiol; 2002 Jan; 13(1):25-32. PubMed ID: 11843479
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A fully automatic, implantable cardioverter-defibrillator algorithm to prevent inappropriate detection of ventricular tachycardia or fibrillation due to T-wave oversensing in spontaneous rhythm.
    Cao J; Gillberg JM; Swerdlow CD
    Heart Rhythm; 2012 Apr; 9(4):522-30. PubMed ID: 22094074
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Experience with an implantable tiered therapy device incorporating antitachycardia pacing and cardioverter/defibrillator therapy.
    Mitchell JD; Lee R; Garan H; Ruskin JN; Torchiana DF; Vlahakes GJ
    J Thorac Cardiovasc Surg; 1993 Mar; 105(3):453-62; discussion 462-3. PubMed ID: 8445925
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Clinical experience with antitachycardia pacing and improved detection algorithms in a new implantable cardioverter-defibrillator.
    Wietholt D; Block M; Isbruch F; Böcker D; Borggrefe M; Shenasa M; Breithardt G
    J Am Coll Cardiol; 1993 Mar; 21(4):885-94. PubMed ID: 8185728
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Performance of an automatic external cardioverter-defibrillator algorithm in the discrimination of supraventricular from ventricular tachycardia.
    Mattioni T; Kanaan N; Riggio D; Bahu M; Lin D; Welch S; Williams C
    Am J Cardiol; 2003 Jun; 91(11):1323-6. PubMed ID: 12767424
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Unique sensing errors in third-generation implantable cardioverter-defibrillators.
    Callans DJ; Hook BG; Kleiman RB; Mitra RL; Flores BT; Marchlinski FE
    J Am Coll Cardiol; 1993 Oct; 22(4):1135-40. PubMed ID: 8409053
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Tachycardia detection in implantable cardioverter-defibrillators by Sorin/LivaNova : Algorithms, pearls and pitfalls].
    Kolb C; Ocklenburg R
    Herzschrittmacherther Elektrophysiol; 2016 Sep; 27(3):213-25. PubMed ID: 27605232
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy.
    Schaumann A; von zur Mühlen F; Gonska BD; Kreuzer H
    Am J Cardiol; 1996 Sep; 78(5A):42-50. PubMed ID: 8820835
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Prevention of inappropriate therapy in implantable cardioverter-defibrillators: results of a prospective, randomized study of tachyarrhythmia detection algorithms.
    Theuns DA; Klootwijk AP; Goedhart DM; Jordaens LJ
    J Am Coll Cardiol; 2004 Dec; 44(12):2362-7. PubMed ID: 15607399
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator. Active Can Investigators.
    Bardy GH; Yee R; Jung W
    J Am Coll Cardiol; 1996 Aug; 28(2):400-10. PubMed ID: 8800117
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Absent ventricular tachycardia detection in a biventricular implantable cardioverter-defibrillator due to intradevice interaction with a rate smoothing pacing algorithm.
    Cooper JM; Sauer WH; Verdino RJ
    Heart Rhythm; 2004 Dec; 1(6):728-31. PubMed ID: 15851247
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Impact of magnetic resonance imaging on ventricular tachyarrhythmia sensing: Results of the Evera MRI Study.
    Gold MR; Sommer T; Schwitter J; Kanal E; Bernabei MA; Love CJ; Surber R; Ramza B; Cerkvenik J; Merkely B
    Heart Rhythm; 2016 Aug; 13(8):1631-5. PubMed ID: 27196818
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [A new ICD morphology criterion for differentiating supraventricular and ventricular tachycardia].
    Korte T; Trappe HJ; Grönefeld G; Schulte B; Wolpert C; Meesmann M; Böcker D; Grosse Meininghaus D; Vogt J; Stellbrink C
    Z Kardiol; 2000 Nov; 89(11):1019-25. PubMed ID: 11149268
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Implantable transvenous cardioverter-defibrillators.
    Bardy GH; Hofer B; Johnson G; Kudenchuk PJ; Poole JE; Dolack GL; Gleva M; Mitchell R; Kelso D
    Circulation; 1993 Apr; 87(4):1152-68. PubMed ID: 8462144
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Interruption of Pacing Following Nonsustained Ventricular Tachycardia in an AAI Programmed Implantable Cardioverter Defibrillator.
    Egan P; Wilkoff BL; Tchou P
    Pacing Clin Electrophysiol; 2015 Sep; 38(9):1082-90. PubMed ID: 26010870
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Lessons learned from data logging in a multicenter clinical trial using a late-generation implantable cardioverter-defibrillator. The Guardian ATP 4210 Multicenter Investigators Group.
    Wood MA; Stambler BS; Damiano RJ; Greenway P; Ellenbogen KA
    J Am Coll Cardiol; 1994 Dec; 24(7):1692-9. PubMed ID: 7963117
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Clinical experience with tiered atrial therapies and atrial arrhythmia prevention algorithms in a dual chamber cardioverter defibrillator.
    Daoud EG; Nademanee K; Fuenzalida C; Tomassoni GF; Schuger C; Chisner M; Simones M; Schwartz M; Reeve H
    J Cardiovasc Electrophysiol; 2006 Aug; 17(8):852-6. PubMed ID: 16903964
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Performance of a dual-chamber implantable defibrillator algorithm for discrimination of ventricular from supraventricular tachycardia.
    Kouakam C; Kacet S; Hazard JR; Ferraci A; Mansour H; Defaye P; Davy JM; Lambiez M;
    Europace; 2004 Jan; 6(1):32-42. PubMed ID: 14697724
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.