These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 8041108)

  • 1. [The manual Polybrene test--the possibilities for its use in immunohematological practice in emergencies].
    Sirakova Zh; Lazarova D; Khristova V; Gŭrcheva L; Tanev M
    Khirurgiia (Sofiia); 1993; 46(4):68-70. PubMed ID: 8041108
    [No Abstract]   [Full Text] [Related]  

  • 2. Serum protein media are important factors in the manual hexadimethrine bromide (polybrene) test, experience in China.
    Liu F; Hu LH
    Transfus Clin Biol; 2005 Feb; 12(1):34-7. PubMed ID: 15814291
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Polybrene technique for red cell antibody screening using microplates.
    Lown JA; Ivey JG
    J Clin Pathol; 1988 May; 41(5):556-7. PubMed ID: 3290265
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Assessment and value of the polybrene microplate test for study and identification of irregular anti-erythrocyte antibodies].
    Guignier F; Domy M; Angue M; Richaud P; Chatelain P
    Rev Fr Transfus Immunohematol; 1986; 29(5):377-89. PubMed ID: 3576046
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Low ionic polybrene (LIP) test for extended blood grouping].
    Nakajima H; Murata M
    Nihon Hoigaku Zasshi; 1984 Apr; 38(2):163-9. PubMed ID: 6434772
    [No Abstract]   [Full Text] [Related]  

  • 6. Is antibody screening in Rh (D)-positive pregnant women necessary?
    Lurie S; Eliezer E; Piper I; Woliovitch I
    J Matern Fetal Neonatal Med; 2003 Dec; 14(6):404-6. PubMed ID: 15061320
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of Rh positive blood in emergency situations.
    Schmidt PJ; Leparc GF; Samia CT
    Surg Gynecol Obstet; 1988 Sep; 167(3):229-33. PubMed ID: 3137672
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hemolytic transfusion reaction due to Rh antibodies detectable only by manual polybrene and polyethylene glycol technique.
    Lin CK; Wong KF; Mak KH; Yuen CM; Lee AW
    Am J Clin Pathol; 1995 Dec; 104(6):660-2. PubMed ID: 8526209
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Remarks on routine use of the enzyme test LEN (LISS Enzyme) in immunohematological studies].
    Walewska I; Seyfriedowa H; Michalewska B; Lenkiewicz B
    Acta Haematol Pol; 1990; 21(2):219-24. PubMed ID: 2131721
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Analysis of irregular antibodies in the department of transfusion medicine 1984-1988].
    Wittkopf D; Grundmann A; Sibrowski W; von Eisenhart-Rothe V; Kühnl P
    Beitr Infusionsther; 1990; 26():415-9. PubMed ID: 1703889
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The manual polybrene test: a simple and rapid procedure for detection of red cell antibodies.
    Lalezari P; Jiang AF
    Transfusion; 1980; 20(2):206-11. PubMed ID: 6768173
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Solidscreen II Enzyme: a complete test method using Solidscreen II].
    Sturmfels L; Knobloch U; Lehmann P; Uthemann H; Lenhard V
    Beitr Infusionsther Transfusionsmed; 1994; 32():179-81. PubMed ID: 9480079
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Immunohematologic surveillance of the pregnant woman and the new prevention policy of anti-RH1 allo-immunization].
    Mannessier L
    Transfus Clin Biol; 2007 May; 14(1):112-9. PubMed ID: 17524695
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Rh blood group system and Rh antibodies].
    Kato T; Ishimaru K; Ikeda H
    Nihon Rinsho; 2010 Jun; 68 Suppl 6():738-42. PubMed ID: 20942177
    [No Abstract]   [Full Text] [Related]  

  • 15. Manual polybrene method for pretransfusion test could overcome the interference of daratumumab therapy in myeloma.
    Yeh TJ; Yeh CJ; Liu YC; Hsiao HH
    Transfusion; 2019 Aug; 59(8):2751-2752. PubMed ID: 31374150
    [No Abstract]   [Full Text] [Related]  

  • 16. [An important source of error in Rh(D) typing].
    Heier HE; Kornstad L; Volle G
    Tidsskr Nor Laegeforen; 1987 Apr; 107(12):1024-6. PubMed ID: 3037723
    [No Abstract]   [Full Text] [Related]  

  • 17. [Detection of irregular alloantibodies by Groupamatic using a trypsin-polybrene-citrate technic].
    Confida S; Hurel C; Muller A; Garretta M
    Rev Fr Transfus Immunohematol; 1978 Mar; 21(2):457-72. PubMed ID: 97758
    [No Abstract]   [Full Text] [Related]  

  • 18. Comparison of a manual hexadimethrine bromide-antiglobulin test with saline- and albumin-antiglobulin tests for pretransfusion testing.
    Mintz PD; Anderson G
    Transfusion; 1987; 27(2):134-7. PubMed ID: 3824470
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The gel centrifugation test in serologic compatibility testing].
    Hitzler W; Bauernfeind U; Schömig-Brekner J; Mathias D
    Beitr Infusionsther; 1990; 26():358-61. PubMed ID: 1703871
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The gel centrifugation test--principles of the method].
    Hitzler W
    Beitr Infusionsther; 1990; 26():370-3. PubMed ID: 1703875
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.