These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 8044616)

  • 1. Comparison of three methods to obtain percutaneous needle core biopsies of a renal allograft.
    Beckingham IJ; Nicholson ML; Kirk G; Veitch PS; Bell PR
    Br J Surg; 1994 Jun; 81(6):898-9. PubMed ID: 8044616
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of ultrasound and cystoscopically guided pancreatic allograft biopsies and transabdominal renal allograft biopsies: safety and efficacy in kidney-pancreas transplant recipients.
    Kuhr CS; Davis CL; Barr D; McVicar JP; Perkins JD; Bachi CE; Alpers CE; Marsh CL
    J Urol; 1995 Feb; 153(2):316-21. PubMed ID: 7815571
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percutaneous renal allograft biopsy. A comparison of two needle types and analysis of risk factors.
    Kolb LG; Velosa JA; Bergstralh EJ; Offord KP
    Transplantation; 1994 Jun; 57(12):1742-6. PubMed ID: 8016879
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous renal transplant biopsy under CAT scanner guidance.
    Rao KV
    Nephron; 1984; 38(4):273-5. PubMed ID: 6392914
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Needle biopsy of renal allografts: comparison of two techniques.
    Bogan ML; Kopecky KK; Kraft JL; Holladay AO; Filo RS; Leapman SB; Thomalla JV
    Radiology; 1990 Jan; 174(1):273-5. PubMed ID: 2403682
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Yield and complications in percutaneous renal biopsy. A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys.
    Nyman RS; Cappelen-Smith J; al Suhaibani H; Alfurayh O; Shakweer W; Akhtar M
    Acta Radiol; 1997 May; 38(3):431-6. PubMed ID: 9191436
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Percutaneous biopsy of renal transplants using ultrasonographic guidance.
    Spigos D; Capek V; Jonasson O
    J Urol; 1977 Jun; 117(6):699-700. PubMed ID: 327091
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous renal biopsy using Monopty needle.
    Jagose JT; Vachharajani TJ; Kulkarni SG; Oza UG; Chitale AR; Kirpalani AL
    J Assoc Physicians India; 1995 Jan; 43(1):19-20. PubMed ID: 9282632
    [TBL] [Abstract][Full Text] [Related]  

  • 9. US-guided renal transplant biopsy: efficacy of a cortical tangential approach.
    Patel MD; Phillips CJ; Young SW; Kriegshauser JS; Chen F; Eversman WG; Silva AC; Lorans R
    Radiology; 2010 Jul; 256(1):290-6. PubMed ID: 20574102
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.
    Chan R; Common AA; Marcuzzi D
    Can Assoc Radiol J; 2000 Apr; 51(2):107-13. PubMed ID: 10786919
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Renal biopsies under ultrasound guidance: 100 consecutive biopsies in children.
    Chan JC; Brewer WH; Still WJ
    J Urol; 1983 Jan; 129(1):103-7. PubMed ID: 6827658
    [TBL] [Abstract][Full Text] [Related]  

  • 12. No change in complication rate using spring-loaded gun compared to traditional percutaneous renal allograft biopsy techniques.
    Kovalik EC; Schwab SJ; Gunnells JC; Bowie D; Smith SR
    Clin Nephrol; 1996 Jun; 45(6):383-5. PubMed ID: 8793230
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Probability of rejection predicted from ultrasonographic measurement of renal transplant swelling.
    Nicholson ML; Bell A; Burton PR; Donnelly PK; Veitch PS; Bell PR
    Br J Surg; 1993 Aug; 80(8):1059-62. PubMed ID: 8402067
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Renal transplant biopsy using real time ultrasound guidance.
    Nicholson ML; Attard AR; Bell A; Donnelly PK; Veitch PS; Bell PR
    Br J Urol; 1990 Jun; 65(6):564-5. PubMed ID: 2196969
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of factors associated with complications following renal transplant needle core biopsy.
    Beckingham IJ; Nicholson ML; Bell PR
    Br J Urol; 1994 Jan; 73(1):13-5. PubMed ID: 8298893
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Re: Percutaneous needle biopsy of the renal allograft using the automated needle system: evaluation of 87 procedures.
    Gómez Veiga F; Chantada Abal V; Gonzalez Martín M
    J Urol; 1994 Sep; 152(3):968. PubMed ID: 8080587
    [No Abstract]   [Full Text] [Related]  

  • 17. Percutaneous renal biopsy in children: a 27-year experience.
    Feneberg R; Schaefer F; Zieger B; Waldherr R; Mehls O; Schärer K
    Nephron; 1998 Aug; 79(4):438-46. PubMed ID: 9689160
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Automatic ultrasound-guided fine needle biopsy of the transplanted kidney. Risks and uses].
    Höppner W; Zantvoort FA; Lison AE; Dreikorn K
    Urologe A; 1994 Sep; 33(5):388-91. PubMed ID: 7974927
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Percutaneous aspiration biopsy of renal allografts using ultrasound localization.
    Parker RA; Elliott WC; Muther RS; Golper TA; Barry JM; Henderson SC; Bennett WM
    Urology; 1980 May; 15(5):534-5. PubMed ID: 6763398
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Usefulness and safety of ultrasound-guided percutaneous needle biopsy in renal allograft patients.
    Kim SI; Moon JI; Kim MS; Kim YS; Park K
    Transplant Proc; 1998 Nov; 30(7):3076. PubMed ID: 9838356
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.