These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 8045244)

  • 1. Forearm tremor during three different isometric loadings.
    Viitasalo JT; Gajewski J; Wit A
    Electromyogr Clin Neurophysiol; 1994; 34(3):131-6. PubMed ID: 8045244
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Forearm tremor in relation to selected physiological and body dimensional variables.
    Viitasalo JT; Mikkonen S; Salonen M; Aura O; Gajewski J; Wit A
    J Sports Med Phys Fitness; 1994 Sep; 34(3):228-34. PubMed ID: 7830385
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii.
    Beck TW; Housh TJ; Johnson GO; Weir JP; Cramer JT; Coburn JW; Malek MH
    J Electromyogr Kinesiol; 2005 Oct; 15(5):482-95. PubMed ID: 15935960
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanomyographic amplitude and mean power frequency versus torque relationships during isokinetic and isometric muscle actions of the biceps brachii.
    Beck TW; Housh TJ; Johnson GO; Weir JP; Cramer JT; Coburn JW; Malek MH
    J Electromyogr Kinesiol; 2004 Oct; 14(5):555-64. PubMed ID: 15301774
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Contribution of motor unit activity enhanced by acute fatigue to physiological tremor of finger.
    Arihara M; Sakamoto K
    Electromyogr Clin Neurophysiol; 1999 Jun; 39(4):235-47. PubMed ID: 10394509
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of a piezoelectric contact sensor and an accelerometer for examining mechanomyographic amplitude and mean power frequency versus torque relationships during isokinetic and isometric muscle actions of the biceps brachii.
    Beck TW; Housh TJ; Johnson GO; Weir JP; Cramer JT; Coburn JW; Malek MH
    J Electromyogr Kinesiol; 2006 Aug; 16(4):324-35. PubMed ID: 16243542
    [TBL] [Abstract][Full Text] [Related]  

  • 7. EMG power spectrum of elbow extensors: a reliability study.
    Bilodeau M; Arsenault AB; Gravel D; Bourbonnais D
    Electromyogr Clin Neurophysiol; 1994; 34(3):149-58. PubMed ID: 8045246
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electromyography tension and frequency spectrum analysis of some masticatory muscles at rest, isotonic and isometric contractions.
    Bazzotti L
    Electromyogr Clin Neurophysiol; 1999; 39(7):421-34. PubMed ID: 10546079
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of electromyographic activity during eccentrically versus concentrically loaded isometric contractions.
    Garner JC; Blackburn T; Weimar W; Campbell B
    J Electromyogr Kinesiol; 2008 Jun; 18(3):466-71. PubMed ID: 17257859
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of location of acceleration sensor on physiological tremor of upper limb.
    Sakamoto K; Yamaji T; Taniri M; Mito K; Takanokura M; Makabe H; Kaneko K; Min BC
    Electromyogr Clin Neurophysiol; 2006; 46(1):3-16. PubMed ID: 16607861
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Characteristics of surface electromyography and work load of the forearm extensors in repetitive wrist extending].
    Dai WT; Zhang FR; Wang ZL; Yang L
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2006 Apr; 24(4):201-4. PubMed ID: 16701029
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does tremor pace repetitive voluntary motor behavior in Parkinson's disease?
    Logigian E; Hefter H; Reiners K; Freund HJ
    Ann Neurol; 1991 Aug; 30(2):172-9. PubMed ID: 1897910
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Paradoxical phenomenon of physiological tremor in prolonged tapping load.
    Takanokura M; Miyamoto Y; Sakamoto K
    Electromyogr Clin Neurophysiol; 2001; 41(5):297-304. PubMed ID: 11572191
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Muscle activation characteristics associated with differences in physiological tremor amplitude between the dominant and non-dominant hand.
    Bilodeau M; Bisson E; Degrâce D; Després I; Johnson M
    J Electromyogr Kinesiol; 2009 Feb; 19(1):131-8. PubMed ID: 17980624
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Subdivision of essential tremor patients according to physiologic characteristics.
    Golan D; Giladi N; Thorne R; Korczyn AD; Simon ES
    Acta Neurol Scand; 2004 Jun; 109(6):393-7. PubMed ID: 15147462
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inter-individual variability in the torque-related patterns of responses for mechanomyographic amplitude and mean power frequency.
    Ryan ED; Cramer JT; Housh TJ; Beck TW; Herda TJ; Hartman MJ
    J Neurosci Methods; 2007 Apr; 161(2):212-9. PubMed ID: 17187865
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Anatomical and mechanical changes following repetitive eccentric exertions.
    Sesto ME; Radwin RG; Block WF; Best TM
    Clin Biomech (Bristol, Avon); 2005 Jan; 20(1):41-9. PubMed ID: 15567535
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Muscle loading as a method to isolate the underlying tremor components in essential tremor and Parkinson's disease.
    Burne JA; Blanche T; Morris JJ
    Muscle Nerve; 2004 Sep; 30(3):347-55. PubMed ID: 15318346
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The relation between physiological tremor and the 13-Hz oscillations of the arm muscles.
    Ritsma W
    Biomed Tech (Berl); 1994 Jun; 39(6):144-8. PubMed ID: 7918974
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of proximal and distal muscles' groups contraction and mental stress on the amplitude and frequency of physiological finger tremor. An accelerometric study.
    Growdon W; Ghika J; Henderson J; van Melle G; Regli F; Bogousslavsky J; Growdon JH
    Electromyogr Clin Neurophysiol; 2000; 40(5):295-303. PubMed ID: 10938996
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.