BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 8045246)

  • 1. EMG power spectrum of elbow extensors: a reliability study.
    Bilodeau M; Arsenault AB; Gravel D; Bourbonnais D
    Electromyogr Clin Neurophysiol; 1994; 34(3):149-58. PubMed ID: 8045246
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Fourier and wavelet transform procedures for examining the mechanomyographic and electromyographic frequency domain responses during fatiguing isokinetic muscle actions of the biceps brachii.
    Beck TW; Housh TJ; Johnson GO; Weir JP; Cramer JT; Coburn JW; Malek MH
    J Electromyogr Kinesiol; 2005 Apr; 15(2):190-9. PubMed ID: 15664148
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of interelectrode distance on electromyographic amplitude and mean power frequency during incremental cycle ergometry.
    Malek MH; Housh TJ; Coburn JW; Weir JP; Schmidt RJ; Beck TW
    J Neurosci Methods; 2006 Mar; 151(2):139-47. PubMed ID: 16122806
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of gender on the EMG power spectrum during an increasing force level.
    Bilodeau M; Arsenault AB; Gravel D; Bourbonnais D
    J Electromyogr Kinesiol; 1992; 2(3):121-9. PubMed ID: 20719605
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characteristics of power spectrum density function of EMG during muscle contraction below 30%MVC.
    Roman-Liu D; Konarska M
    J Electromyogr Kinesiol; 2009 Oct; 19(5):864-74. PubMed ID: 18590966
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii.
    Beck TW; Housh TJ; Johnson GO; Weir JP; Cramer JT; Coburn JW; Malek MH
    J Electromyogr Kinesiol; 2005 Oct; 15(5):482-95. PubMed ID: 15935960
    [TBL] [Abstract][Full Text] [Related]  

  • 7. EMG power spectra of elbow extensors during ramp and step isometric contractions.
    Bilodeau M; Arsenault AB; Gravel D; Bourbonnais D
    Eur J Appl Physiol Occup Physiol; 1991; 63(1):24-8. PubMed ID: 1915327
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effects of innervation zone on electromyographic amplitude and mean power frequency during incremental cycle ergometry.
    Malek MH; Coburn JW; Weir JP; Beck TW; Housh TJ
    J Neurosci Methods; 2006 Jul; 155(1):126-33. PubMed ID: 16510193
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of muscular ultrasound stimulation on power spectrum electromyography during a strengthening training.
    Montes Molina R; Martin Garcia MS; Gonzalez Mayoral ML
    Electromyogr Clin Neurophysiol; 2000; 40(3):163-8. PubMed ID: 10812539
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of EMG power-spectrum and amplitude of the semitendinosus and biceps femoris muscles during ramp isometric contractions.
    Kellis E; Katis A
    J Electromyogr Kinesiol; 2008 Jun; 18(3):351-8. PubMed ID: 17254801
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new EMG frequency-based fatigue threshold test.
    Hendrix CR; Housh TJ; Johnson GO; Mielke M; Camic CL; Zuniga JM; Schmidt RJ
    J Neurosci Methods; 2009 Jun; 181(1):45-51. PubMed ID: 19394361
    [TBL] [Abstract][Full Text] [Related]  

  • 12. EMG power spectrum and features of the superimposed M-wave during voluntary eccentric and concentric actions at different activation levels.
    Linnamo V; Strojnik V; Komi PV
    Eur J Appl Physiol; 2002 Apr; 86(6):534-40. PubMed ID: 11944102
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reliability of mechanomyographic amplitude and mean power frequency during isometric step and ramp muscle actions.
    Herda TJ; Ryan ED; Beck TW; Costa PB; DeFreitas JM; Stout JR; Cramer JT
    J Neurosci Methods; 2008 Jun; 171(1):104-9. PubMed ID: 18405977
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modulation of EMG power spectrum frequency during motor imagery.
    Lebon F; Rouffet D; Collet C; Guillot A
    Neurosci Lett; 2008 Apr; 435(3):181-5. PubMed ID: 18343579
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The influence of an increase in the level of force on the EMG power spectrum of elbow extensors.
    Bilodeau M; Arsenault AB; Gravel D; Bourbonnais D
    Eur J Appl Physiol Occup Physiol; 1990; 61(5-6):461-6. PubMed ID: 2079067
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The reversal of antagonists facilitates the peak rate of tension development.
    Gabriel DA; Basford JR; An KN
    Arch Phys Med Rehabil; 2001 Mar; 82(3):342-6. PubMed ID: 11245756
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The influence of the type of contraction on the masseter muscle EMG power spectrum.
    Nadeau S; Bilodeau M; Delisle A; Chmielewski W; Arsenault AB; Gravel D
    J Electromyogr Kinesiol; 1993; 3(4):205-13. PubMed ID: 20870535
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Time and frequency domain responses of the mechanomyogram and electromyogram during isometric ramp contractions: a comparison of the short-time Fourier and continuous wavelet transforms.
    Ryan ED; Cramer JT; Egan AD; Hartman MJ; Herda TJ
    J Electromyogr Kinesiol; 2008 Feb; 18(1):54-67. PubMed ID: 17070700
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The mechanomyography of persons after stroke during isometric voluntary contractions.
    Hu XL; Tong KY; Li L
    J Electromyogr Kinesiol; 2007 Aug; 17(4):473-83. PubMed ID: 16603386
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cocontraction of the elbow muscles during combined tasks of pronation-flexion and supination-flexion.
    Hébert LJ; De Serres SJ; Arsenault AB
    Electromyogr Clin Neurophysiol; 1991 Dec; 31(8):483-8. PubMed ID: 1797544
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.