BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

194 related articles for article (PubMed ID: 8046132)

  • 1. Real or apparent entrapment of a Swan-Ganz pulmonary artery catheter after cardiac surgery?
    Benson J; Patla V
    Intensive Care Med; 1994; 20(4):309-10. PubMed ID: 8046132
    [No Abstract]   [Full Text] [Related]  

  • 2. Entrapment of a Swan-Ganz catheter.
    Chen LC; Huang PH
    J Chin Med Assoc; 2007 May; 70(5):213-4. PubMed ID: 17524999
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Entrapment of a Swan-Ganz catheter within the right pulmonary artery ligature during right pneumonectomy].
    Heves Karagöz A; Kanbak M; Celebioğlu B; Akinci SB; Kara M; Doğan R
    Tuberk Toraks; 2009; 57(1):81-3. PubMed ID: 19533443
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Swan-Ganz catheter-induced severe complications in cardiac surgery: right ventricular perforation, knotting, and rupture of a pulmonary artery.
    Bossert T; Gummert JF; Bittner HB; Barten M; Walther T; Falk V; Mohr FW
    J Card Surg; 2006; 21(3):292-5. PubMed ID: 16684066
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Entrapment of pulmonary artery catheter in a suture at the inferior vena cava cannulation site.
    Huang L; Elsharydah A; Nawabi A; Cork RC
    J Clin Anesth; 2004 Nov; 16(7):557-9. PubMed ID: 15590265
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Complications caused by a Swan-Ganz catheter. An inadvertent entrapment in the right atrium during cardiac surgery].
    Seitz W; Kaukemüller J; Frank G
    Anaesthesist; 1989 May; 38(5):259-61. PubMed ID: 2735522
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Pulmonary artery rupture caused by a Swan-Ganz catheter during heart surgery. A successful therapeutic procedure].
    Hess W; Marggraf G; Reidemeister C
    Anaesthesist; 1988 Jul; 37(7):446-9. PubMed ID: 3414956
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transesophageal echocardiographic diagnosis of intracardiac entrapment of a Swan-Ganz catheter in open heart operation.
    Wang HJ; Wang SS; Liau CS
    J Am Soc Echocardiogr; 2004 Mar; 17(3):277-9. PubMed ID: 14981428
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Catheter-induced pulmonary artery perforation during cardiac surgery: intraoperative surgical management.
    Reber D; Aebert H; Pfeifer M; Keyl C; Birnbaum DE
    Panminerva Med; 1996 Dec; 38(4):259-61. PubMed ID: 9063036
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Swan-Ganz catheter entrapment in open heart surgery.
    Kaplan M; Demirtas M; Cimen S; Kut MS; Ozay B; Kanca A; Ozler A
    J Card Surg; 2000; 15(5):313-5. PubMed ID: 11599822
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Swan-Ganz catheter-induced massive hemoptysis and pulmonary artery false aneurysm.
    Feng WC; Singh AK; Drew T; Donat W
    Ann Thorac Surg; 1990 Oct; 50(4):644-6. PubMed ID: 2222056
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An infrequent complication of Swan-Ganz catheters.
    Racionero MA; Prados C; Acitores I; Lazaro-Carrasco MT; Alvarez-Sala R
    J Cardiovasc Surg (Torino); 1995 Oct; 36(5):519-20. PubMed ID: 8522576
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Severe Tricuspid Regurgitation After Percutaneous Removal of a Swan-Ganz Catheter Caught by Suture.
    Gennari M; Bartorelli AL; Polvani G; Muratori M; Ferrari C; Penza E; Arlati FG; Agrifoglio M
    Ann Thorac Surg; 2017 Sep; 104(3):e225-e226. PubMed ID: 28838512
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Swan-Ganz catheter induced pulmonary artery perforation during cardiac surgery concerning two cases.
    Sekkal S; Cornu E; Christidès C; Laskar M; Serhal C; Ghossein Y; Ostyn E; Sellami M; Michel JM
    J Cardiovasc Surg (Torino); 1996 Jun; 37(3):313-7. PubMed ID: 8698771
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Peroperative opening of a patent foramen ovale caused by pulmonary artery obstruction due to knotted pulmonary artery catheter.
    Tavan R; Coronel B; Duperret S; Meeus P; Blondet R
    Eur J Anaesthesiol; 2002 Feb; 19(2):145-6. PubMed ID: 11999599
    [No Abstract]   [Full Text] [Related]  

  • 16. Multiple knotting of a swan-ganz catheter.
    Asensi Bonet N; Osseyran Samper F; Loro Represa JM; Vicente Guillén R
    Rev Esp Cardiol; 2010 Jul; 63(7):869-70. PubMed ID: 20609323
    [No Abstract]   [Full Text] [Related]  

  • 17. Pulmonary artery pseudoaneurysm after Swan-Ganz catheterization: a case presentation and review of literature.
    Nellaiyappan M; Omar HR; Justiz R; Sprenker C; Camporesi EM; Mangar D
    Eur Heart J Acute Cardiovasc Care; 2014 Sep; 3(3):281-8. PubMed ID: 24470440
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Erroneous cardiac output measurement due to loop formation of a Swan-Ganz catheter in the pulmonary artery.
    Schummer W; Schummer C; Schummer C
    J Clin Anesth; 2004 May; 16(3):235-6. PubMed ID: 15217669
    [No Abstract]   [Full Text] [Related]  

  • 19. Swan-Ganz catheter-induced pseudoaneurysm of the pulmonary artery.
    Utsumi T; Kido T; Ohata T; Yasukawa M; Takano H; Sakakibara T
    Jpn J Thorac Cardiovasc Surg; 2002 Aug; 50(8):347-9. PubMed ID: 12229220
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Renal injury caused by pulmonary artery catheter repositioning.
    Yokote J; Watanabe I; Usui A; Oshima H; Kato W; Takahashi H; Ueda Y
    J Cardiothorac Vasc Anesth; 2009 Jun; 23(3):379-80. PubMed ID: 18834801
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 10.