These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

255 related articles for article (PubMed ID: 8050424)

  • 41. [Monitoring of anaesthesia breathing systems by capnography (author's transl)].
    Krivosic-Horber R; Cacheux G; Hanoulle P
    Anesth Analg (Paris); 1979; 36(9-10):403-8. PubMed ID: 532995
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Accuracy of prediction of fresh gas flow requirements during spontaneous breathing with the T-piece.
    Lindahl SG; Charlton AJ; Hatch DJ
    Eur J Anaesthesiol; 1984 Sep; 1(3):269-74. PubMed ID: 6443091
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Back to basics--a simplified non-mathematical approach to low flow techniques in anaesthesia.
    Baker AB
    Anaesth Intensive Care; 1994 Aug; 22(4):394-5. PubMed ID: 7978203
    [No Abstract]   [Full Text] [Related]  

  • 44. Humidity of anaesthetic gases with respect to low flow anaesthesia.
    Kleemann PP
    Anaesth Intensive Care; 1994 Aug; 22(4):396-408. PubMed ID: 7978204
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Respiratory waveform and rebreathing in T-piece circuits: a comparison of enflurane and halothane waveforms.
    Byrick RJ; Janssen EG
    Anesthesiology; 1980 Nov; 53(5):371-8. PubMed ID: 6775562
    [TBL] [Abstract][Full Text] [Related]  

  • 46. End tidal carbon dioxide monitoring in spontaneously breathing, nonintubated patients. A clinical comparison between conventional sidestream and microstream capnometers.
    Casati A; Gallioli G; Passaretta R; Scandroglio M; Bignami E; Torri G
    Minerva Anestesiol; 2001 Apr; 67(4):161-4. PubMed ID: 11376503
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Comparison of the Bain system and Uniflow universal anaesthetic breathing systems in spontaneously breathing young pigs.
    Almubarak A; Clarke K; Jackson TL
    Vet Anaesth Analg; 2005 Sep; 32(5):314-21. PubMed ID: 16135213
    [TBL] [Abstract][Full Text] [Related]  

  • 48. High flow closed circuit anaesthesia.
    Verkaaik AP; Van Dijk G
    Anaesth Intensive Care; 1994 Aug; 22(4):426-34. PubMed ID: 7978208
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Human chest wall function while awake and during halothane anesthesia. II. Carbon dioxide rebreathing.
    Warner DO; Warner MA
    Anesthesiology; 1995 Jan; 82(1):20-31. PubMed ID: 7832302
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Ventilatory responses to rebreathing and carbon dioxide inhalation during anaesthesia in children.
    Lindahl SG; Charlton AJ; Hatch DJ
    Br J Anaesth; 1985 Dec; 57(12):1188-96. PubMed ID: 3936525
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Use of the laryngeal mask for closed circuit anesthesia.
    Stacey MR; Morris S; Asai T
    Middle East J Anaesthesiol; 1996 Oct; 13(6):593-604. PubMed ID: 8987039
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Measuring rebreathing in spontaneous ventilation. A new lung model.
    Cook LB; Watt S; Peachey G; Chakrabarti MK
    Anaesthesia; 1996 Mar; 51(3):241-6. PubMed ID: 8712324
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Respiratory diagnostic possibilities during closed circuit anesthesia.
    Verkaaik AP; Erdmann W
    Acta Anaesthesiol Belg; 1990; 41(3):177-88. PubMed ID: 2260424
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Determination of ventilatory minute volumes for normocapnic ventilation under anaesthesia in healthy adults.
    Puri GD; Singh H; Kaushik S; Jindal SK
    Natl Med J India; 1999; 12(1):6-11. PubMed ID: 10326322
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Preliminary evaluation of the Enclosed Magill Breathing System.
    Bruce WE; Soni NC
    Br J Anaesth; 1989 Feb; 62(2):144-9. PubMed ID: 2493797
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The influence of fresh gas flow and inspiratory/expiratory ratio on tidal volume and arterial CO2 tension in mechanically ventilated surgical patients.
    Scheller MS; Jones BR; Benumof JL
    J Cardiothorac Anesth; 1989 Oct; 3(5):564-7. PubMed ID: 2520934
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [Accessory anesthetic breathing systems: verification before use].
    Otteni JC; Cazalaà JB; Beydon L; Bourgain JL; Dalens B; Feiss P; Nivoche Y; Servin F; Safran D
    Ann Fr Anesth Reanim; 1999 Feb; 18(2):243-8. PubMed ID: 10207599
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Effects of spontaneous breathing with BIPAP on pulmonary gas exchange in patients with ARDS.
    Hörmann C; Baum M; Putensen C; Kleinsasser A; Benzer H
    Acta Anaesthesiol Scand Suppl; 1997; 111():152-5. PubMed ID: 9420993
    [No Abstract]   [Full Text] [Related]  

  • 59. Expiratory limb ventilation during unique failure of the anesthesia machine breathing circuit.
    Seif DM; Olympio MA
    Anesthesiology; 2013 Mar; 118(3):751-3. PubMed ID: 23426211
    [No Abstract]   [Full Text] [Related]  

  • 60. Carbon dioxide output in anaesthesia.
    Bain JA; Spoerel WE
    Can Anaesth Soc J; 1976 Mar; 23(2):153-62. PubMed ID: 1252973
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.