These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

72 related articles for article (PubMed ID: 8051471)

  • 1. Stress-protecting effects of semi-rigid titanium alloy plates on osteotomized rabbit tibiae.
    Sei A; Nakamura E; Nakamura T; Takagi K
    Nihon Seikeigeka Gakkai Zasshi; 1994 May; 68(5):448-57. PubMed ID: 8051471
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bone-bonding behavior of titanium alloy evaluated mechanically with detaching failure load.
    Takatsuka K; Yamamuro T; Nakamura T; Kokubo T
    J Biomed Mater Res; 1995 Feb; 29(2):157-63. PubMed ID: 7537743
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Less rigid internal fixation plates: historical perspectives and new concepts.
    Woo SL; Lothringer KS; Akeson WH; Coutts RD; Woo YK; Simon BR; Gomez MA
    J Orthop Res; 1984; 1(4):431-49. PubMed ID: 6491792
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanical effects of metal plate fixation. In vitro investigation on intact and osteotomized human and rabbit tibiae.
    Terjesen T; Benum P
    Acta Orthop Scand; 1983 Apr; 54(2):256-62. PubMed ID: 6846003
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Titanium alloy mini-implants for orthodontic anchorage: immediate loading and metal ion release.
    Morais LS; Serra GG; Muller CA; Andrade LR; Palermo EF; Elias CN; Meyers M
    Acta Biomater; 2007 May; 3(3):331-9. PubMed ID: 17257912
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of the bone-plate material and the presence of a gap between the fractured bone and plate on the predicted stresses at the fractured bone.
    Fouad H
    Med Eng Phys; 2010 Sep; 32(7):783-9. PubMed ID: 20627657
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical and histomorphometric characterizations of osseointegration during mini-screw healing in rabbit tibiae.
    Wu J; Bai YX; Wang BK
    Angle Orthod; 2009 May; 79(3):558-63. PubMed ID: 19413379
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A comparative study of effects on bone healing and remodelling between embracing fixator and bone].
    Wu X; Dai K; Qiu S
    Zhonghua Wai Ke Za Zhi; 1995 Aug; 33(8):481-4. PubMed ID: 8706565
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bone remodelling after internal fixation with different stiffness plates: ultrastructural investigation.
    Chen YQ; Dai KR; Qiu SJ; Zhu ZA
    Chin Med J (Engl); 1994 Oct; 107(10):766-70. PubMed ID: 7835104
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stress shielding by rigid fixation studied in osteotomized rabbit tibiae.
    Låftman P; Nilsson OS; Brosjö O; Strömberg L
    Acta Orthop Scand; 1989 Dec; 60(6):718-22. PubMed ID: 2624096
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The stress-protecting effect of metal plates on the intact rabbit tibia.
    Terjesen T; Benum P
    Acta Orthop Scand; 1983 Dec; 54(6):810-8. PubMed ID: 6670503
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new bioactive glass--ceramic as a coating material on titanium alloy.
    Takatsuka K; Yamamuro T; Kitsugi T; Nakamura T; Shibuya T; Goto T
    J Appl Biomater; 1993; 4(4):317-29. PubMed ID: 10172006
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Morphological study of the microcirculation in regional cortical bones affected by internal fixation plates].
    Wang Y
    Zhonghua Wai Ke Za Zhi; 1993 Apr; 31(4):248-50. PubMed ID: 8275846
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model.
    Ochman S; Doht S; Paletta J; Langer M; Raschke MJ; Meffert RH
    J Hand Surg Am; 2010 Apr; 35(4):597-603. PubMed ID: 20299161
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A parametric study of the factors affecting the fatigue strength of porous coated Ti-6A1-4V implant alloy.
    Kohn DH; Ducheyne P
    J Biomed Mater Res; 1990 Nov; 24(11):1483-501. PubMed ID: 2279982
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal- and mechanical-loading.
    Vásquez VZ; Ozcan M; Kimpara ET
    Dent Mater; 2009 Feb; 25(2):221-31. PubMed ID: 18718654
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The role of titanium implant surface modification with hydroxyapatite nanoparticles in progressive early bone-implant fixation in vivo.
    Lin A; Wang CJ; Kelly J; Gubbi P; Nishimura I
    Int J Oral Maxillofac Implants; 2009; 24(5):808-16. PubMed ID: 19865620
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bone healing performance of electrophoretically deposited apatite-wollastonite/chitosan coating on titanium implants in rabbit tibiae.
    Sharma S; Patil DJ; Soni VP; Sarkate LB; Khandekar GS; Bellare JR
    J Tissue Eng Regen Med; 2009 Oct; 3(7):501-11. PubMed ID: 19621346
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Local delivery of growth factors from coated titanium plates increases osteotomy healing in rats.
    Wildemann B; Bamdad P; Holmer Ch; Haas NP; Raschke M; Schmidmaier G
    Bone; 2004 May; 34(5):862-8. PubMed ID: 15121018
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An initial study of diffusion bonds between superplastic Ti-6Al-4V for implant dentistry applications.
    Elias KL; Daehn GS; Brantley WA; McGlumphy EA
    J Prosthet Dent; 2007 Jun; 97(6):357-65. PubMed ID: 17618918
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.