These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Interference of lupus anticoagulants in prothrombin time assays: implications for selection of adequate methods to optimize the management of thrombosis in the antiphospholipid-antibody syndrome. Della Valle P; Crippa L; Garlando AM; Pattarini E; Safa O; Viganò D'Angelo S; D'Angelo A Haematologica; 1999 Dec; 84(12):1065-74. PubMed ID: 10586206 [TBL] [Abstract][Full Text] [Related]
5. Potential failure of the International Normalized Ratio (INR) System in the monitoring of oral anticoagulation in patients with lupus anticoagulants. Della Valle P; Crippa L; Safa O; Tomassini L; Pattarini E; Vigano-D'Angelo S; Grazia Sabbadini M; D'Angelo A Ann Med Interne (Paris); 1996 Sep; 147 Suppl 1():10-4. PubMed ID: 8952752 [TBL] [Abstract][Full Text] [Related]
6. [Comparison of Quick/INR values of whole capillary blood (CoaguChek Plus) and venous citrate plasma in patients with and without oral anticoagulation]. Burri S; Demarmels Biasiutti F; Lämmle B; Wuillemin WA Schweiz Med Wochenschr; 1998 Oct; 128(44):1723-9. PubMed ID: 9846345 [TBL] [Abstract][Full Text] [Related]
7. Performance evaluation of a new small-volume coagulation monitor: the SmartCheck INR system. Gardiner C; Longair I; Hills J; Cohen H; Mackie IJ; Machin SJ Am J Clin Pathol; 2008 Mar; 129(3):500-4. PubMed ID: 18285276 [TBL] [Abstract][Full Text] [Related]
8. Discrepant sensitivity of thromboplastin reagents to clotting factor levels explored by the prothrombin time in patients on stable oral anticoagulant treatment: impact on the international normalized ratio system. Testa S; Morstabilini G; Fattorini A; Galli L; Denti N; D'Angelo A Haematologica; 2002 Dec; 87(12):1265-73. PubMed ID: 12495900 [TBL] [Abstract][Full Text] [Related]
9. Capillary whole blood testing by a new portable monitor. Comparison with standard determination of the international normalized ratio. de Miguel D; Burgaleta C; Reyes E; Pascual T Am J Clin Pathol; 2003 Jul; 120(1):28-33. PubMed ID: 12866369 [TBL] [Abstract][Full Text] [Related]
10. [Inter-institute variations in International Normalized Ratio and thrombotest]. Nozawa T; Hayashi S; Naiki S; Niiya K; Asanoi H; Inoue H J Cardiol; 1998 Aug; 32(2):89-94. PubMed ID: 9752617 [TBL] [Abstract][Full Text] [Related]
11. INR comparison between the CoaguChek Pro PT(N) and a standard laboratory method. Khoschnewis S; Hannes FM; Tschopp M; Wuillemin WA Thromb Res; 2004; 113(5):327-32. PubMed ID: 15183045 [TBL] [Abstract][Full Text] [Related]
12. [Relationship between prothrombin time international normalized ratio and thrombo test (%)]. Numata Y; Ogata Y; Arao K; Mizumasa Y; Wakita T; Haruguchi H; Araki H; Tsuji T; Mawatari K; Shimada K J Cardiol; 2001 Dec; 38(6):327-35. PubMed ID: 11806090 [TBL] [Abstract][Full Text] [Related]
13. Multicenter evaluation of a chromogenic substrate method for photometric determination of prothrombin time. Dati F; Barthels M; Conard J; Flückiger J; Girolami A; Hänseler E; Huber J; Keller F; Kolde HJ; Müller-Berghaus G Thromb Haemost; 1987 Oct; 58(3):856-65. PubMed ID: 3433249 [TBL] [Abstract][Full Text] [Related]
14. Comparison and evaluation of a Point-of-care device (CoaguChek XS) to Owren-type prothrombin time assay for monitoring of oral anticoagulant therapy with warfarin. Wieloch M; Hillarp A; Strandberg K; Nilsson C; Svensson PJ Thromb Res; 2009 Jul; 124(3):344-8. PubMed ID: 19423152 [TBL] [Abstract][Full Text] [Related]
15. Comparison between CoaguChek S- and Owren-type prothrombin time assay for monitoring anticoagulant therapy. Jonsson M; Hillarp A; Svensson P Thromb Res; 2004; 114(2):83-9. PubMed ID: 15306149 [TBL] [Abstract][Full Text] [Related]
16. [The factors that influence the consistency of international normalized ratio of prothrombin time]. Su W; Ren FQ Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2001 Apr; 23(2):196-8. PubMed ID: 12905903 [TBL] [Abstract][Full Text] [Related]
17. Prothrombin time in liver failure: time, ratio, activity percentage, or international normalized ratio? Robert A; Chazouillères O Hepatology; 1996 Dec; 24(6):1392-4. PubMed ID: 8938167 [TBL] [Abstract][Full Text] [Related]
18. [A study on anticoagulation for cardiovascular diseases using international normalized ratio (INR)]. Izumi Y; Asada H; Hoshino Z; Yoshida H; Kubota H Kyobu Geka; 1996 Nov; 49(12):997-1000. PubMed ID: 8937001 [TBL] [Abstract][Full Text] [Related]
19. Quality assurance program for whole blood prothrombin time-international normalized ratio point-of-care monitors used for patient self-testing to control oral anticoagulation. Tripodi A; Bressi C; Carpenedo M; Chantarangkul V; Clerici M; Mannucci PM Thromb Res; 2004; 113(1):35-40. PubMed ID: 15081563 [TBL] [Abstract][Full Text] [Related]
20. Agreement of a new whole-blood PT/INR test using capillary samples with plasma INR determinations. Boehlen F; Reber G; de Moerloose P Thromb Res; 2005; 115(1-2):131-4. PubMed ID: 15567464 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]