These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 805962)

  • 1. [Proceedings: Experience with a transcutaneously chargeable pacemaker system].
    Grosser KD; Vogel W; Heller A; Asbeck F; Steinbrück G
    MMW Munch Med Wochenschr; 1975 May; 117(20):838. PubMed ID: 805962
    [No Abstract]   [Full Text] [Related]  

  • 2. [Long term therapy with the pacemakers].
    Kleinert M
    Med Klin; 1975 Nov; 70(48):1947-53. PubMed ID: 813103
    [No Abstract]   [Full Text] [Related]  

  • 3. Current concepts in pacing.
    Carver J; Spitzer S; Mason D
    Geriatrics; 1981 Mar; 36(3):105-16. PubMed ID: 7215802
    [No Abstract]   [Full Text] [Related]  

  • 4. [Proceedings: Prolongation of funtion time of implantable pacemakers through the reduction of impulse duration].
    Wirtzfeld A; Himmler Ch; Lampadius M; Schmück L; Präuer H
    MMW Munch Med Wochenschr; 1975 May; 117(20):839. PubMed ID: 805964
    [No Abstract]   [Full Text] [Related]  

  • 5. The pacemaker challenge.
    Goldman BS; Noble EJ; Heller JG; Covvey D
    Can Med Assoc J; 1974 Jan; 110(1):28-31. PubMed ID: 4809444
    [No Abstract]   [Full Text] [Related]  

  • 6. Early clinical experience with the rechargeable cardiac pacemaker.
    Lewis KB; Criley JM; Nelson RJ; Love JW
    Ann Thorac Surg; 1974 Nov; 18(5):490-3. PubMed ID: 4441149
    [No Abstract]   [Full Text] [Related]  

  • 7. [Interference of pacemaker stimulation due to battery rotation (pacemaker-twiddler syndrome)].
    Schulten HK; du Mesnil de Rochemont W; Jochem W; Baldus O; Grosser KD; Behrenbeck DW
    Med Welt; 1975 Aug; 26(31-32):1406-7. PubMed ID: 1165711
    [No Abstract]   [Full Text] [Related]  

  • 8. Transvenous pacemaker placement in a community hospital. A ten-year experience.
    McNamara JJ; Grant V; Matsuda S
    Hawaii Med J; 1978 Mar; 37(3):76-8. PubMed ID: 640830
    [No Abstract]   [Full Text] [Related]  

  • 9. Clinical experience with radioisotopic-powered cardiac pacemakers.
    Smyth NP; Hernandex T; Deitz R; Johnson A
    Md State Med J; 1975 Apr; 24(4):47-9. PubMed ID: 1128002
    [No Abstract]   [Full Text] [Related]  

  • 10. The current status of cardiac pacing.
    Roy OZ
    CRC Crit Rev Bioeng; 1975 Jun; 2(3):259-327. PubMed ID: 1095301
    [No Abstract]   [Full Text] [Related]  

  • 11. [Can an electric pacemaker be powered by the body's own energy? A medico-technical speculation].
    Benkert G; Fabian W
    Fortschr Med; 1981 Aug; 99(31-32):1211-3. PubMed ID: 7274935
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new radioisotope-powered cardiac pacer.
    Purdy DL; Magovern GJ; Smyth NP
    J Thorac Cardiovasc Surg; 1975 Jan; 69(1):82-91. PubMed ID: 1110579
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Optimum impulse period in cardiac pacemaker therapy].
    Wirtzfeld A; Himmler C; Lampadius M; Schmück L; Präuer H
    Verh Dtsch Ges Inn Med; 1975; 81():158-60. PubMed ID: 1229483
    [No Abstract]   [Full Text] [Related]  

  • 14. The lithium iodide--powered cardiac pacemaker. Clinical experience with 250 implantations.
    Burr LH
    J Thorac Cardiovasc Surg; 1977 Mar; 73(3):421-3. PubMed ID: 839832
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical experience with new pulse generator using narrow pulse width for conserving battery energy.
    Smyth NP; Alferness C; Shearon L; Walmsley F; Keshishian JM; Baker NR; Johnson A
    Med Instrum; 1974; 8(6):326-30. PubMed ID: 4431333
    [No Abstract]   [Full Text] [Related]  

  • 16. Comparative experience with endocardial and epicardial pacemakers.
    Bello A; Sanchez E; Lairet A; Gallardo J; Jaen R
    J Cardiovasc Surg (Torino); 1974; 15(5):528-31. PubMed ID: 4215817
    [No Abstract]   [Full Text] [Related]  

  • 17. A pacemaker driven by a biogalvanic element.
    Schaldach M
    Adv Biomed Eng Med Phys; 1970; 3():321-33. PubMed ID: 5527795
    [No Abstract]   [Full Text] [Related]  

  • 18. Future power sources for cardiac pacemakers.
    Cheatham JE
    Singapore Med J; 1973 Sep; 14(3):433-4. PubMed ID: 4777927
    [No Abstract]   [Full Text] [Related]  

  • 19. Maneuver to avoid asystole during change of pacemaker.
    Rao G; Ford WB; Zikria EA; Miller WH; Samadani SR
    Int Surg; 1974 Oct; 59(10):558. PubMed ID: 4613680
    [No Abstract]   [Full Text] [Related]  

  • 20. Preliminary clinical experience with a new radioisotope-powered cardiac pacemaker.
    Smyth NP; Magovern GJ; Cushing WJ; Keshishian JM; Kelly LC; Dixon M
    J Thorac Cardiovasc Surg; 1976 Feb; 71(2):262-7. PubMed ID: 1107679
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.