These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Relative blood damage in the three phases of a prosthetic heart valve flow cycle. Lamson TC; Rosenberg G; Geselowitz DB; Deutsch S; Stinebring DR; Frangos JA; Tarbell JM ASAIO J; 1993; 39(3):M626-33. PubMed ID: 8268614 [TBL] [Abstract][Full Text] [Related]
4. Effects of the driving condition of a pneumatic ventricular assist device on the cavitation intensity of the inlet and outlet mechanical heart valves. Lee H; Tatsumi E; Taenaka Y ASAIO J; 2009; 55(4):328-34. PubMed ID: 19506466 [TBL] [Abstract][Full Text] [Related]
5. In-vivo prediction of cavitation near a Medtronic Hall valve. Johansen P; Andersen TS; Hasenkam JM; Nygaard H J Heart Valve Dis; 2004 Jul; 13(4):651-8. PubMed ID: 15311874 [TBL] [Abstract][Full Text] [Related]
6. A comparison of the cavitation potential of prosthetic heart valves based on valve closing dynamics. Zapanta CM; Stinebring DR; Deutsch S; Geselowitz DB; Tarbell JM J Heart Valve Dis; 1998 Nov; 7(6):655-67. PubMed ID: 9870200 [TBL] [Abstract][Full Text] [Related]
7. The effect of dissolved carbon dioxide on cavitation intensity in mechanical heart valves. Herbertson LH; Manning KB; Reddy V; Fontaine AA; Tarbell JM; Deutsch S J Heart Valve Dis; 2005 Nov; 14(6):835-42. PubMed ID: 16363068 [TBL] [Abstract][Full Text] [Related]
8. Characteristics of mechanical heart valve cavitation in a pneumatic ventricular assist device. Lee H; Taenaka Y Artif Organs; 2008 Jun; 32(6):453-60. PubMed ID: 18422801 [TBL] [Abstract][Full Text] [Related]
9. Effect of structural compliance on cavitation threshold measurement of mechanical heart valves. Guo GX; Adlparvar P; Howanec M; Roy J; Kafesjian R; Kingsbury C J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S77-83; discussion S83-4. PubMed ID: 8061872 [TBL] [Abstract][Full Text] [Related]
10. Pressure field in the vicinity of mechanical valve occluders at the instant of valve closure: correlation with cavitation initiation. Chandran KB; Lee CS; Chen LD J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S65-75; discussion S75-6. PubMed ID: 8061871 [TBL] [Abstract][Full Text] [Related]
11. In vitro observations of mechanical heart valve cavitation. Shu MC; Leuer LH; Armitage TL; Schneider TE; Christiansen DR J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S85-92; discussion S92-3. PubMed ID: 8061874 [TBL] [Abstract][Full Text] [Related]
12. Effect of systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: using a monoleaflet valve. Lee H; Tatsumi E; Taenaka Y ASAIO J; 2008; 54(1):25-30. PubMed ID: 18204312 [TBL] [Abstract][Full Text] [Related]
13. Role of vortices in cavitation formation in the flow across a mechanical heart valve. Li CP; Lu PC; Liu JS; Lo CW; Hwang NH J Heart Valve Dis; 2008 Jul; 17(4):435-45. PubMed ID: 18751474 [TBL] [Abstract][Full Text] [Related]
14. Causes and formation of cavitation in mechanical heart valves. Graf T; Reul H; Detlefs C; Wilmes R; Rau G J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S49-64. PubMed ID: 8061870 [TBL] [Abstract][Full Text] [Related]
16. Study of an acoustic technique to detect cavitation produced by a tilting disc valve. Herman BA; Porter JM; Carey RF J Heart Valve Dis; 1996 Jan; 5(1):90-6. PubMed ID: 8834731 [TBL] [Abstract][Full Text] [Related]
17. Acoustic and visual characteristics of cavitation induced by mechanical heart valves. Sohn K; Manning KB; Fontaine AA; Tarbell JM; Deutsch S J Heart Valve Dis; 2005 Jul; 14(4):551-8. PubMed ID: 16116884 [TBL] [Abstract][Full Text] [Related]