These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 8061909)

  • 21. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear.
    Davidson JA
    Clin Orthop Relat Res; 1993 Sep; (294):361-78. PubMed ID: 8358943
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Failures of yttria-stabilised tetragonal zirconia: 52 retrieved ceramic femoral heads of total hip prostheses.
    Fernández-Fairén M; Sala P; Gil FJ
    Biomed Mater Eng; 2006; 16(6):415-22. PubMed ID: 17119280
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A multi-directional wear screening device and preliminary results of UHMWPE articulating against stainless steel.
    Joyce TJ; Monk D; Scholes SC; Unsworth A
    Biomed Mater Eng; 2000; 10(3-4):241-9. PubMed ID: 11202152
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening device.
    McKellop H; Clarke I; Markolf K; Amstutz H
    J Biomed Mater Res; 1981 Sep; 15(5):619-53. PubMed ID: 12659132
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.
    Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J
    J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads.
    Galvin AL; Jennings LM; Tipper JL; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2010 Oct; 224(10):1175-83. PubMed ID: 21138235
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Wear of ultra-high molecular weight polyethylene against damaged and undamaged stainless steel and diamond-like carbon-coated counterfaces.
    Firkins P; Hailey JL; Fisher J; Lettington AH; Butter R
    J Mater Sci Mater Med; 1998 Oct; 9(10):597-601. PubMed ID: 15348693
    [TBL] [Abstract][Full Text] [Related]  

  • 29. PIRAC Ti nitride coated Ti-6AI-4V head against UHMWPE acetabular cup-hip wear simulator study.
    Gutmanas EY; Gotman I
    J Mater Sci Mater Med; 2004 Apr; 15(4):327-30. PubMed ID: 15332594
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.
    Roy ME; Whiteside LA; Magill ME; Katerberg BJ
    Clin Orthop Relat Res; 2011 Aug; 469(8):2337-45. PubMed ID: 21312076
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Development of a ceramic surface replacement for the hip. An experimental Sialon model.
    Clarke IC; Phillips W; McKellop H; Coster IR; Hedley A; Amstutz HC
    Biomater Med Devices Artif Organs; 1979; 7(1):111-26. PubMed ID: 454775
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The wear of a polyethylene socket articulating with a zirconia ceramic femoral head in canine total hip arthroplasty.
    Hamada Y; Horiuchi T; Sano Y; Usui I
    J Biomed Mater Res; 1999; 48(3):301-8. PubMed ID: 10398034
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Alumina femoral head fracture: an in vitro study.
    Affatato S; Ghisolfi E; Cacciari GL; Toni A
    Int J Artif Organs; 2000 Apr; 23(4):256-60. PubMed ID: 10832660
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses.
    Endo M; Tipper JL; Barton DC; Stone MH; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2002; 216(2):111-22. PubMed ID: 12022418
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Wear characteristics of sliding pairs of zirconia (Y-TZP) for hip endoprostheses.
    Willmann G; Früh HJ; Pfaff HG
    Biomaterials; 1996 Nov; 17(22):2157-62. PubMed ID: 8922601
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical experience with ceramics in total hip replacement.
    Oonishi H; Wakitani S; Murata N; Saito M; Imoto K; Kim S; Matsuura M
    Clin Orthop Relat Res; 2000 Oct; (379):77-84. PubMed ID: 11039795
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Prediction of plastic strains in ultra-high molecular weight polyethylene due to microscopic asperity interactions during sliding wear.
    McNie C; Barton DC; Stone MH; Fisher J
    Proc Inst Mech Eng H; 1998; 212(1):49-56. PubMed ID: 9529936
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A parametric analysis of the contact stress in ultra-high molecular weight polyethylene acetabular cups.
    Jin ZM; Dowson D; Fisher J
    Med Eng Phys; 1994 Sep; 16(5):398-405. PubMed ID: 7952678
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Oxidation in ultrahigh molecular weight polyethylene and cross-linked polyethylene acetabular cups tested against roughened femoral heads in a hip joint simulator.
    Taddei P; Affatato S; Fagnano C; Toni A
    Biomacromolecules; 2006 Jun; 7(6):1912-20. PubMed ID: 16768414
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The effect of the surface finish of alumina and stainless steel on the wear rate of UHMW polyethylene.
    Weightman B; Light D
    Biomaterials; 1986 Jan; 7(1):20-4. PubMed ID: 3955153
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.