These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
166 related articles for article (PubMed ID: 8078362)
1. Measuring and representing peripheral oedema and its alterations. Casley-Smith JR Lymphology; 1994 Jun; 27(2):56-70. PubMed ID: 8078362 [TBL] [Abstract][Full Text] [Related]
2. Measurement decisions for clinical assessment of limb volume changes in patients with bilateral and unilateral limb edema. Mayrovitz HN; Macdonald J; Davey S; Olson K; Washington E Phys Ther; 2007 Oct; 87(10):1362-8. PubMed ID: 17684090 [TBL] [Abstract][Full Text] [Related]
3. Alterations of untreated lymphedema and it's grades over time. Casley-Smith JR Lymphology; 1995 Dec; 28(4):174-85. PubMed ID: 8771010 [TBL] [Abstract][Full Text] [Related]
4. Upper-extremity volume measurements in women with lymphedema: a comparison of measurements obtained via water displacement with geometrically determined volume. Sander AP; Hajer NM; Hemenway K; Miller AC Phys Ther; 2002 Dec; 82(12):1201-12. PubMed ID: 12444879 [TBL] [Abstract][Full Text] [Related]
5. Concurrent validity of upper-extremity volume estimates: comparison of calculated volume derived from girth measurements and water displacement volume. Karges JR; Mark BE; Stikeleather SJ; Worrell TW Phys Ther; 2003 Feb; 83(2):134-45. PubMed ID: 12564949 [TBL] [Abstract][Full Text] [Related]
6. Defining lower limb lymphedema after inguinal or ilio-inguinal dissection in patients with melanoma using classification and regression tree analysis. Spillane AJ; Saw RP; Tucker M; Byth K; Thompson JF Ann Surg; 2008 Aug; 248(2):286-93. PubMed ID: 18650640 [TBL] [Abstract][Full Text] [Related]
7. Hand volume estimates based on a geometric algorithm in comparison to water displacement. Mayrovitz HN; Sims N; Hill CJ; Hernandez T; Greenshner A; Diep H Lymphology; 2006 Jun; 39(2):95-103. PubMed ID: 16910100 [TBL] [Abstract][Full Text] [Related]
8. Tissue tonometry: a useful tool for assessing filarial lymphedema. Kar SK; Kar PK; Mania J Lymphology; 1992 Jun; 25(2):55-61. PubMed ID: 1405748 [TBL] [Abstract][Full Text] [Related]
9. Postmastectomy lymphoedema. Treatment and a five-year follow-up study. Berlin E; Gjöres JE; Ivarsson C; Palmqvist I; Thagg G; Thulesius O Int Angiol; 1999 Dec; 18(4):294-8. PubMed ID: 10811517 [TBL] [Abstract][Full Text] [Related]
10. Single frequency versus bioimpedance spectroscopy for the assessment of lymphedema. York SL; Ward LC; Czerniec S; Lee MJ; Refshauge KM; Kilbreath SL Breast Cancer Res Treat; 2009 Sep; 117(1):177-82. PubMed ID: 18563555 [TBL] [Abstract][Full Text] [Related]
11. Validation of the inverse water volumetry method: A new gold standard for arm volume measurements. Damstra RJ; Glazenburg EJ; Hop WC Breast Cancer Res Treat; 2006 Oct; 99(3):267-73. PubMed ID: 16752072 [TBL] [Abstract][Full Text] [Related]
12. [Comparison of different methods to quantify the volume of horse limbs]. Haase F; Siewert C; von Rautenfeld DB; Fischbach JU; Seifert H Berl Munch Tierarztl Wochenschr; 2009; 122(3-4):126-31. PubMed ID: 19350812 [TBL] [Abstract][Full Text] [Related]
13. Reliability and validity of arm volume measurements for assessment of lymphedema. Taylor R; Jayasinghe UW; Koelmeyer L; Ung O; Boyages J Phys Ther; 2006 Feb; 86(2):205-14. PubMed ID: 16445334 [TBL] [Abstract][Full Text] [Related]
14. Limb circumference measurement for recording edema volume in patients with filarial lymphedema. Pani SP; Vanamail P; Yuvaraj J Lymphology; 1995 Jun; 28(2):57-63. PubMed ID: 7564492 [TBL] [Abstract][Full Text] [Related]
15. Validity for the simplified water displacement instrument to measure arm lymphedema as a result of breast cancer surgery. Sagen A; Kåresen R; Skaane P; Risberg MA Arch Phys Med Rehabil; 2009 May; 90(5):803-9. PubMed ID: 19406300 [TBL] [Abstract][Full Text] [Related]
16. Validation of an optoelectronic limb volumeter (Perometer). Stanton AW; Northfield JW; Holroyd B; Mortimer PS; Levick JR Lymphology; 1997 Jun; 30(2):77-97. PubMed ID: 9215977 [TBL] [Abstract][Full Text] [Related]
17. Reliability and limits of agreement of circumferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema. Deltombe T; Jamart J; Recloux S; Legrand C; Vandenbroeck N; Theys S; Hanson P Lymphology; 2007 Mar; 40(1):26-34. PubMed ID: 17539462 [TBL] [Abstract][Full Text] [Related]
18. Factors influencing response to lymphonodovenous shunt in filarial lymphoedema. Rao YG; Ananthakrishnan N; Pani SP; Kate V; Yuvaraj J; Krishnamoorthy K Natl Med J India; 1999; 12(2):55-8. PubMed ID: 10416319 [TBL] [Abstract][Full Text] [Related]
19. Comparison of volume displacement versus circumferential arm measurements for lymphoedema: implications for the SNAC trial. Tewari N; Gill PG; Bochner MA; Kollias J ANZ J Surg; 2008 Oct; 78(10):889-93. PubMed ID: 18959643 [TBL] [Abstract][Full Text] [Related]