These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 8091624)

  • 1. An in vitro biomechanical investigation of an interlocking nail for fixation of diaphyseal tibial fractures in adult horses.
    McDuffee LA; Stover SM; Taylor KT; Les CM
    Vet Surg; 1994; 23(4):219-30. PubMed ID: 8091624
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An in vitro biomechanical investigation of an equine interlocking nail.
    McDuffee LA; Stover SM; Bach JM; Taylor KT
    Vet Surg; 2000; 29(1):38-47. PubMed ID: 10653493
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro cyclic biomechanical properties of an interlocking equine tibial nail.
    McDuffee LA; Stover SM; Taylor KT
    Vet Surg; 2000; 29(2):163-72. PubMed ID: 10730709
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An in vitro biomechanical comparison of two interlocking-nail systems for fixation of ostectomized equine third metacarpal bones.
    Lopez MJ; Wilson DG; Trostle SS; Markel MD
    Vet Surg; 2001; 30(3):246-52. PubMed ID: 11340556
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An in vitro biomechanical investigation of the mechanical properties of dynamic compression plated osteotomized adult equine tibiae.
    McDuffee LA; Stover SM; Taylor KT
    Vet Surg; 1997; 26(2):126-36. PubMed ID: 9068163
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An in vitro biomechanical investigation of an MP35N intramedullary interlocking nail system for repair of third metacarpal fractures in adult horses.
    Galuppo LD; Stover SM; Aldridge A; Hewes C; Taylor KT
    Vet Surg; 2002; 31(3):211-25. PubMed ID: 11994848
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An in vitro biomechanical comparison of interlocking nail constructs and double plating for fixation of diaphyseal femur fractures in immature horses.
    Radcliffe RM; Lopez MJ; Turner TA; Watkins JP; Radcliffe CH; Markel MD
    Vet Surg; 2001; 30(2):179-90. PubMed ID: 11230773
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An in vitro biomechanical comparison of an interlocking nail system and dynamic compression plate fixation of ostectomized equine third metacarpal bones.
    Lopez MJ; Wilson DG; Vanderby R; Markel MD
    Vet Surg; 1999; 28(5):333-40. PubMed ID: 10493637
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
    Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro biomechanical comparison of a plate-rod combination-construct and an interlocking nail-construct for experimentally induced gap fractures in canine tibiae.
    von Pfeil DJ; Déjardin LM; DeCamp CE; Meyer EG; Lansdowne JL; Weerts RJ; Haut RC
    Am J Vet Res; 2005 Sep; 66(9):1536-43. PubMed ID: 16261826
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical study of nine different tibia locking nails.
    Schandelmaier P; Krettek C; Tscherne H
    J Orthop Trauma; 1996; 10(1):37-44. PubMed ID: 8926553
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
    Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
    J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interlocking screw configuration influences distal tibial fracture stability in torsional loading after intramedullary nailing.
    Lowenberg DW; DeBaun MR; Behn A; Sox-Harris A
    Eur J Orthop Surg Traumatol; 2020 Oct; 30(7):1205-1213. PubMed ID: 32367222
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modified tibial nails for treating distal tibia fractures.
    Gorczyca JT; McKale J; Pugh K; Pienkowski D
    J Orthop Trauma; 2002 Jan; 16(1):18-22. PubMed ID: 11782627
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
    Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
    J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Geometric properties of the fractured tibia stabilized by unreamed interlocking nail: development of a three-dimensional finite element model.
    Raunest J; Kynast W; Lesch V; Kukulies U; Hackländer T; Schwarting KH; Arnold G
    Comput Biomed Res; 1996 Aug; 29(4):259-70. PubMed ID: 8812073
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Biomechanical studies of 9 tibial interlocking nails in a bone-implant unit].
    Schandelmaier P; Krettek C; Tscherne H
    Unfallchirurg; 1994 Nov; 97(11):600-8. PubMed ID: 7817197
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influences of some design parameters on the biomechanics of the unreamed tibial intramedullary nail.
    Henley MB; Meier M; Tencer AF
    J Orthop Trauma; 1993; 7(4):311-9. PubMed ID: 8377039
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical evaluation of a threaded interference interlocking mechanism for angle-stable intramedullary nailing.
    Hanlon J; Kim SE
    Am J Vet Res; 2024 Jul; 85(7):. PubMed ID: 38848749
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.