These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 8093140)

  • 1. Excursions of the cervical spine during tracheal intubation: blind oral intubation compared with direct laryngoscopy.
    Fitzgerald RD; Krafft P; Skrbensky G; Pernerstorfer T; Steiner E; Kapral S; Weinstabl C
    Anaesthesia; 1994 Feb; 49(2):111-5. PubMed ID: 8093140
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tracheal intubation and cervical spine excursion: direct laryngoscopy vs. intubating laryngeal mask.
    Waltl B; Melischek M; Schuschnig C; Kabon B; Erlacher W; Nasel C; Fuchs M; Kapral S
    Anaesthesia; 2001 Mar; 56(3):221-6. PubMed ID: 11251427
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The disposition of the cervical spine and deformation of available cord space with conventional- and balloon laryngoscopy-guided laryngeal intubation: a comparative study.
    Mentzelopoulos SD; Tzoufi MJ; Papageorgiou EP
    Anesth Analg; 2001 May; 92(5):1331-6. PubMed ID: 11323372
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intubating Laryngeal Mask Airway-assisted Flexible Bronchoscopic Intubation Is Associated With Reduced Cervical Spine Motion When Compared With C-MAC Video Laryngoscopy-guided Intubation: A Prospective Randomized Cross Over Trial.
    Swain A; Bhagat H; Gupta V; Salunke P; Panda NB; Sahu S
    J Neurosurg Anesthesiol; 2020 Jul; 32(3):242-248. PubMed ID: 30893284
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of cervical spine movement during laryngoscopy using the Airtraq or Macintosh laryngoscopes.
    Hirabayashi Y; Fujita A; Seo N; Sugimoto H
    Anaesthesia; 2008 Jun; 63(6):635-40. PubMed ID: 18477276
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope.
    Hirabayashi Y; Fujita A; Seo N; Sugimoto H
    Anaesthesia; 2007 Oct; 62(10):1050-5. PubMed ID: 17845658
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Upper cervical vertebrae movement during intubating laryngeal mask, fibreoptic and direct laryngoscopy: a video-fluoroscopic study.
    Sahin A; Salman MA; Erden IA; Aypar U
    Eur J Anaesthesiol; 2004 Oct; 21(10):819-23. PubMed ID: 15678738
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope.
    Rudolph C; Schneider JP; Wallenborn J; Schaffranietz L
    Anaesthesia; 2005 Jul; 60(7):668-72. PubMed ID: 15960717
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cervical spine motion during tracheal intubation with King Vision™ video laryngoscopy and conventional laryngoscopy: a crossover randomized study.
    El-Tahan MR; El Kenany S; Khidr AM; Al Ghamdi AA; Tawfik AM; Al Mulhim AS
    Minerva Anestesiol; 2017 Nov; 83(11):1152-1160. PubMed ID: 28607336
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Randomized cross-over comparison of cervical-spine motion with the AirWay Scope or Macintosh laryngoscope with in-line stabilization: a video-fluoroscopic study.
    Maruyama K; Yamada T; Kawakami R; Hara K
    Br J Anaesth; 2008 Oct; 101(4):563-7. PubMed ID: 18660500
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury.
    Watts AD; Gelb AW; Bach DB; Pelz DM
    Anesthesiology; 1997 Dec; 87(6):1335-42. PubMed ID: 9416718
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Upper cervical spine movement during intubation: fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope.
    Maruyama K; Yamada T; Kawakami R; Kamata T; Yokochi M; Hara K
    Br J Anaesth; 2008 Jan; 100(1):120-4. PubMed ID: 18070787
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus GlideScope videolaryngoscopy.
    Robitaille A; Williams SR; Tremblay MH; Guilbert F; Thériault M; Drolet P
    Anesth Analg; 2008 Mar; 106(3):935-41, table of contents. PubMed ID: 18292443
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cervical spine motion with direct laryngoscopy and orotracheal intubation. An in vivo cinefluoroscopic study of subjects without cervical abnormality.
    Sawin PD; Todd MM; Traynelis VC; Farrell SB; Nader A; Sato Y; Clausen JD; Goel VK
    Anesthesiology; 1996 Jul; 85(1):26-36. PubMed ID: 8694378
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Segmental cervical spine movement with the intubating laryngeal mask during manual in-line stabilization in patients with cervical pathology undergoing cervical spine surgery.
    Kihara S; Watanabe S; Brimacombe J; Taguchi N; Yaguchi Y; Yamasaki Y
    Anesth Analg; 2000 Jul; 91(1):195-200. PubMed ID: 10866912
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cervical spine motion during flexible bronchoscopy compared with the Lo-Pro GlideScope.
    Wong DM; Prabhu A; Chakraborty S; Tan G; Massicotte EM; Cooper R
    Br J Anaesth; 2009 Mar; 102(3):424-30. PubMed ID: 19193652
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Cervical spine motion during laryngoscopy with the Pentax-AWS with a new thinner blade (Introck-T)].
    Hirabayashi Y; Fujita A; Sugimoto H
    Masui; 2013 Jun; 62(6):682-5. PubMed ID: 23814991
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cervical spine motion during airway management: a cinefluoroscopic study of the posteriorly destabilized third cervical vertebrae in human cadavers.
    Brimacombe J; Keller C; Künzel KH; Gaber O; Boehler M; Pühringer F
    Anesth Analg; 2000 Nov; 91(5):1274-8. PubMed ID: 11049921
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Cervical spine movement during orotracheal intubation using the McCoy laryngoscope compared with the Macintosh and the Miller laryngoscopes].
    Konishi A; Sakai T; Nishiyama T; Higashizawa T; Bito H
    Masui; 1997 Jan; 46(1):124-7. PubMed ID: 9028096
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Cervival spine movement during light-guided orotracheal intubation with lightwand stylet (Trachlight)].
    Konishi A; Kikuchi K; Sasui M
    Masui; 1998 Jan; 47(1):94-7. PubMed ID: 9492509
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.